scholarly journals A solid-phase microextraction fiber coating based on magnetic covalent organic framework for highly efficient extraction of triclosan and methyltriclosan in environmental water and human urine samples

2021 ◽  
Vol 219 ◽  
pp. 112319
Author(s):  
Yanyan Li ◽  
Guozhong Dong ◽  
Jianye Li ◽  
Jianxing Xiang ◽  
Jingrui Yuan ◽  
...  
Toxins ◽  
2022 ◽  
Vol 14 (1) ◽  
pp. 42
Author(s):  
Noelia Pallarés ◽  
Dionisia Carballo ◽  
Emilia Ferrer ◽  
Yelko Rodríguez-Carrasco ◽  
Houda Berrada

Human biomonitoring constitutes a suitable tool to assess exposure to toxins overcoming the disadvantages of traditional methods. Urine constitutes an accessible biological matrix in biomonitoring studies. Mycotoxins are secondary metabolites produced naturally by filamentous fungi that produce a wide range of adverse health effects. Thus, the determination of urinary mycotoxin levels is a useful tool for assessing the individual exposure to these food contaminants. In this study, a suitable methodology has been developed to evaluate the presence of aflatoxin B2 (AFB2), aflatoxin (AFG2), ochratoxin A (OTA), ochratoxin B (OTB), zearalenone (ZEA), and α-zearalenol (α-ZOL) in urine samples as exposure biomarkers. For this purpose, different extraction procedures, namely, the Solid Phase Extraction (SPE); Dispersive Liquid–Liquid Microextraction (DLLME); and Quick, Easy, Cheap, Effective, Rugged, and Safe (QuEChERS) methods were assessed, followed by Liquid Chromatography coupled to Quadrupole Time of Flight Mass Spectrometry with Electrospray Ionization (LC-ESI-QTOF-MS) determination. Then, the proposed methodology was applied to determine mycotoxin concentrations in 56 human urine samples from volunteers and to estimate the potential risk of exposure. The results obtained revealed that 55% of human urine samples analyzed resulted positive for at least one mycotoxin. Among all studied mycotoxins, only AFB2, AFG2, and OTB were detected with incidences of 32, 41, and 9%, respectively, and levels in the range from <LOQ to 69.42 µg/L. Risk assessment revealed a potential health risk, obtaining MoE values < 10,000. However, it should be highlighted that few samples were contaminated, and that more data about mycotoxin excretion rates and their BMDL10 values are needed for a more accurate risk assessment.


Author(s):  
Tomasz Tuzimski ◽  
Szymon Szubartowski

In this study, we propose a simple, cost-effective, and sensitive high-performance liquid chromatography method with fluorescence detection (HPLC-FLD) for the simultaneous determination of the three bisphenols (BPs): bisphenol A bis (2,3-dihydroxypropyl) ether (BADGE 2H2O), bisphenol F (BPF), and bisphenol E (BPE) in human urine samples. The dispersive solid phase extraction (d-SPE) coupled with solid phase extraction (SPE) procedure performed well for the analytes with recoveries in the range of 74.3–86.5% and relative standard deviations (RSD%) less than 10%. The limits of quantification (LOQs) for all investigated analytes were in the range of 11.42–22.35 ng mL−1. The method was validated at three concentration levels (1 × LOQ, 1.5 × LOQ, and 3 LOQ). During the bisphenols HPLC-FLD analysis, from 6 min a reinforcement (10 or 12) was used, therefore analytes might be identified in the small volume human urine samples. The results demonstrated clearly that the approach developed provides reliable, simple, and rapid quantification and identification of three bisphenols in a urine matrix and could be used for monitoring these analytes.


2020 ◽  
Vol 12 (19) ◽  
pp. 2434-2442 ◽  
Author(s):  
Lian Wen ◽  
Peng Wu ◽  
Lei-Lei Wang ◽  
Li-Zong Chen ◽  
Ming-Lin Wang ◽  
...  

This study indicated the promising applicability of the TpPa-1 as a solid-phase microextraction fiber coating for reliably detecting synthetic musks at trace levels from environmental samples.


Sign in / Sign up

Export Citation Format

Share Document