Heat transfer analysis and effects of feeding tubes arrangement, falling film behavior and backsplash on ice formation around horizontal tubes bundles

2013 ◽  
Vol 73 ◽  
pp. 317-328 ◽  
Author(s):  
Hani Hussain Sait
Author(s):  
Hani H. Sait ◽  
Ahmed Hussain ◽  
Abduzahir M. Selim

The heat exchangers for ice formation on tube essentially consists of cold pipes submersed in stagnant water or in a cross flow of water. The heat exchanger considered here is a falling film one. Water falling film falls down over a set of vertical in-line cold horizontal tubes. The falling film main modes are droplets, jets, and sheet depending on its flow rate. The tubes are internally cooled by a controlled subzero temperature coolant. The coolant passes through the pipes in parallel. Water falling film freezes gradually outside the test tubes. The quantity of ice formed on the test tubes is observed, photographed, and measured at different times for different falling film modes. It has been noticed that the rate of ice formation decreases with time as ice accumulates on the test tubes. The overall heat transfer coefficient decreases as more ice accumulates on the test tubes.


2020 ◽  
Vol 142 (12) ◽  
Author(s):  
Avijit Karmakar ◽  
Sumanta Acharya

Abstract The performance of a falling-film heat exchanger is strongly linked to the surface characteristics and the heat transfer processes that take place over the tubes. The primary aim of this numerical study is to characterize the influence of surface wettability on the film flow behavior and its associated surface heat transfer in the jet-flow mode. Volume of fluid (VOF) based simulations are carried out for horizontal tubes with different surface wettabilities. The wettability of the tube surfaces is represented using the Kistler's dynamic contact angle model. Surface wettability effects ranging from superhydrophilic to superhydrophobic are studied by varying the equilibrium contact angle from 2 deg to 175 deg. Two different liquid mass flow rates of 0.06 and 0.18 kg/m-s corresponding to the inline and staggered jet flow modes are studied. Results are presented in terms of the liquid film thickness, the contact areas between the different phases (solid–liquid and liquid–air), and the heat transfer coefficient or Nusselt number. The resistance imposed by the increasing contact angles inhibits the extent of the liquid spreading over the tube surface, and this, in turn, influences the liquid film thickness, and the wetted area of the tube surface. A significant decrement in the heat transfer rate from the tube surfaces was observed as the equilibrium contact angle increased from 2 deg to 175 deg. The local distributions of the Nusselt number over the tube surface are strongly influenced by the flow recirculation in the liquid bulk.


2011 ◽  
Vol 236-238 ◽  
pp. 1572-1575 ◽  
Author(s):  
Hong Liu ◽  
Hu Gen Ma ◽  
Chang Sheng Li

Experimental investigation of falling film evaporation on horizontal tubes was carried out in this paper. Tube surface, spray flow rate and coolant flow rate were the factors considered in the experiment. The impact on falling film evaporation performance was obtained as expected. Experimental results are obtained that the heat transfer performances of low finned tubes are better than that of smooth tubes. The increasing of flow rate enhances heat transfer performance of falling film evaporation at first, while the flow rate gets a certain value, it will hinder the improvement of heat transfer performance. It was also found that there is almost no effects on heat transfer coefficient when the flow rate of coolant changes.


Sign in / Sign up

Export Citation Format

Share Document