Can cadaverous pollution from environmental lead misguide to false positive results in the histochemical determination of Gunshot Residues? In-depth study using ultra-sensitive ICP-MS analysis on cadaveric skin samples

2018 ◽  
Vol 292 ◽  
pp. 23-26 ◽  
Author(s):  
Michele Boracchi ◽  
Salvatore Andreola ◽  
Federica Collini ◽  
Guendalina Gentile ◽  
Giorgio Lucchini ◽  
...  
2017 ◽  
Vol 277 ◽  
pp. 16-20 ◽  
Author(s):  
Michele Boracchi ◽  
Salvatore Andreola ◽  
Federica Collini ◽  
Guendalina Gentile ◽  
Francesca Maciocco ◽  
...  

2020 ◽  
Vol 70 (12) ◽  
pp. 4594-4600

The purpose of this study was to characterize some types of biomass wastes resulted from different activities such as: agriculture, forestry and food industry using thermogravimetric and ICP-MS analyses. Also, it was optimized an ICP-MS method for the determination of As, Cd and Pb from biomass ash samples. The ICP-MS analysis revealed that the highest concentration of metals (As, Cd, Pb) was recorded in the wood waste ash sample, also the thermogravimetric analysis indicated that the highest amount of ash was obtained for the same sample (26.82%). The biomass wastes mentioned in this study are alternative recyclable materials, reusable as pellets and briquettes. Keywords: ash, biomass, ICP-MS, minor elements, TG


Chemosensors ◽  
2021 ◽  
Vol 9 (4) ◽  
pp. 77
Author(s):  
Davide Spanu ◽  
Gilberto Binda ◽  
Marcello Marelli ◽  
Laura Rampazzi ◽  
Sandro Recchia ◽  
...  

A laser ablation–inductively coupled plasma–mass spectrometry (LA–ICP–MS) based method is proposed for the quantitative determination of the spatial distribution of metal nanoparticles (NPs) supported on planar substrates. The surface is sampled using tailored ablation patterns and the data are used to define three-dimensional functions describing the spatial distribution of NPs. The volume integrals of such interpolated surfaces are calibrated to obtain the mass distribution of Ag NPs by correlation with the total mass of metal as determined by metal extraction and ICP–MS analysis. Once this mass calibration is carried out on a sacrificial sample, quantifications can be performed over multiple samples by a simple micro-destructive LA–ICP–MS analysis without requiring the extraction/dissolution of metal NPs. The proposed approach is here tested using a model sample consisting of a low-density polyethylene (LDPE) disk decorated with silver NPs, achieving high spatial resolution over cm2-sized samples and very high sensitivity. The developed method is accordingly a useful analytical tool for applications requiring both the total mass and the spatial distribution of metal NPs to be determined without damaging the sample surface (e.g., composite functional materials and NPs, decorated catalysts or electrodic materials).


1988 ◽  
Vol 71 (4) ◽  
pp. 857-859
Author(s):  
Walter Holak ◽  
John J Specchio

Abstract When lead and cadmium were determined in samples of canned food by the AOAC anodic stripping voltammetric method, an interference was observed which was believed to be tin(IV). This interference could cause false positive results for lead and cadmium. The electroactivity of tin(IV) was suppressed by increasing the concentration of tartaric acid in the supporting electrolyte from 0.005M to 0.1M after mixing with an equal volume of sample solution.


2019 ◽  
Vol 85 (4) ◽  
pp. 110-113
Author(s):  
Olexandr Ponomarenko ◽  
Anatolyi Samchuk ◽  
Kateryna Vovk ◽  
Igor Shvaika ◽  
Ganna Grodzinskaya

The analytical technologies of sample preparation of rocks and mushrooms using the microwave field for the determination of germanium by the method of mass spectrometry with inductively coupled plasma (ICP-MS analysis) have been developed. Germanium is a rare element. Germanium is homology of silicon and carbon. To date, the definition of low content of germanium in geological objects is a rather complex analytical task, which requires its concentration - extraction, co-precipitation, ion exchange. At present, the harmonious combination of the method of natural objects decomposition in the microwave field and germanium determination using ICP-MS analysis is particularly promising. Sample preparation of silicate rocks for ICP-MS determination of germanium was carried out by decomposition in a mixture of hydrofluoric, phosphate and nitric acids (5: 5: 2) in a microwave oven program at 240°C for 30 min. Sample preparation of mushrooms for ICP-MS germanium determination was carried out according to the following scheme. Initially, the dried sample was sealed in the presence of CaO, after dissolving it in a mixture of HNO3+HF+H3PO4 (6:6:1). Ge solution was extracted by Nazarenko V.A. extraction method. The developed analytical schemes have made it possible to significantly reduce the duration and labor intensity of sample preparation. The obtained solutions were analyzed using an inductively coupled plasma mass spectrometer. The developed method for determining germanium by ICP-MS analysis has been successfully tested on standard rock samples. The obtained results are in accordance with the accepted attribute, the relative standard deviation Sr ranges from 0.7-0.9. The data on the content and distribution of germanium in the Boletales fungi are obtained. They indicate wild mushrooms contain high levels of germanium, especially Boletus and Mushroom biospores. These studies are necessary because the essential properties of germanium and its compounds attract special attention of scientists today. Complementary Ge compounds which have hypotensive, bactericidal, antiviral and antitumor effects have already been synthesized.


2013 ◽  
Vol 61 (28) ◽  
pp. 6991-6998 ◽  
Author(s):  
Sumontha Nookabkaew ◽  
Nuchanart Rangkadilok ◽  
Chulabhorn Mahidol ◽  
Gunlatida Promsuk ◽  
Jutamaad Satayavivad

Sign in / Sign up

Export Citation Format

Share Document