scholarly journals An Evaluation of the Effect of Stimulation Parameters and Electrode Type on Bicep Muscle Response for a Voltage-controlled Functional Electrical Stimulator

2017 ◽  
Vol 50 (1) ◽  
pp. 15109-15114 ◽  
Author(s):  
Ashley M. Stewart ◽  
Christopher G. Pretty ◽  
XiaoQi Chen
Author(s):  
S. J. Mahendra ◽  
Viswanath Talasila ◽  
Abhilash G. Dutt ◽  
Mukund Balaji ◽  
Abhishek C. Mouli

Functional electrical stimulation is an assistive technique that utilizes electrical discharges to produce functional movements in patients suffering from neurological impairments. In this work, a biphasic, programmable current- controlled functional electrical stimulator system is designed to enable hand grasping facilitated by wrist flexion. The developed system utilizes an operational amplifier based current source and is supported by a user interface to adjust stimulation parameters. The device is integrated with an accelerometer to measure the degree of stimulated movement. The system is validated, firstly, on two passive electrical loads and subsequently on four healthy volunteers. The device is designed to deliver currents between 0-30mA, and the error between the measured current and simulated current for two loads were -0.967±0.676mA and -0.995±0.97mA. The angular data from the accelerometer provided information regarding variations in movement between the subjects. The architecture of the proposed system is such that it can, in principle, automatically adjust the parameters of simulation to induce the desired movement optimally by measuring a stimulated movement artifact (e.g., angular position) in real time.


Electronics ◽  
2020 ◽  
Vol 9 (7) ◽  
pp. 1156
Author(s):  
Tyler Ward ◽  
Neil Grabham ◽  
Chris Freeman ◽  
Yang Wei ◽  
Ann-Marie Hughes ◽  
...  

We present biphasic stimulator electronics developed for a wearable functional electrical stimulation system. The reported stimulator electronics consist of a twenty four channel biphasic stimulator. The stimulator circuitry is physically smaller per channel and offers a greater degree of control over stimulation parameters than existing functional electrical stimulator systems. The design achieves this by using, off the shelf multichannel high voltage switch integrated circuits combined with discrete current limiting and dc blocking circuitry for the frontend, and field programmable gate array based logic to manage pulse timing. The system has been tested on both healthy adults and those with reduced upper limb function following a stroke. Initial testing on healthy users has shown the stimulator can reliably generate specific target gestures such as palm opening or pointing with an average accuracy of better than 4 degrees across all gestures. Tests on stroke survivors produced some movement but this was limited by the mechanical movement available in those users’ hands.


2014 ◽  
Vol 2014 ◽  
pp. 1-9 ◽  
Author(s):  
Bingquan Zhu ◽  
Yongbing Wang ◽  
Guozheng Yan ◽  
Pingping Jiang ◽  
Zhiqiang Liu

Electrical stimulation has been suggested as a possible treatment for various functional gastrointestinal disorders (FGID). This paper presents a transcutaneous power supplied implantable electrical stimulation system. This technology solves the problem of supplying extended power to an implanted electrical stimulator. After implantation, the stimulation parameters can be reprogrammed by the external controller and then transmitted to the implanted stimulator. This would enable parametric studies to investigate the efficacy of various stimulation parameters in promoting gastrointestinal contractions. A pressure detector in the internal stimulator can provide real-time feedback about variations in the gastrointestinal tract. An optimal stimulation protocol leading to cecal contractions has been proposed: stimulation bursts of 3 ms pulse width, 10 V amplitude, 40 Hz frequency, and 20 s duration. The animal experiment demonstrated the functionality of the system and validated the effects of different stimulation parameters on cecal contractions.


2020 ◽  
Vol 132 (6) ◽  
pp. 2000-2007 ◽  
Author(s):  
Soroush Niketeghad ◽  
Abirami Muralidharan ◽  
Uday Patel ◽  
Jessy D. Dorn ◽  
Laura Bonelli ◽  
...  

Stimulation of primary visual cortices has the potential to restore some degree of vision to blind individuals. Developing safe and reliable visual cortical prostheses requires assessment of the long-term stability, feasibility, and safety of generating stimulation-evoked perceptions.A NeuroPace responsive neurostimulation system was implanted in a blind individual with an 8-year history of bare light perception, and stimulation-evoked phosphenes were evaluated over 19 months (41 test sessions). Electrical stimulation was delivered via two four-contact subdural electrode strips implanted over the right medial occipital cortex. Current and charge thresholds for eliciting visual perception (phosphenes) were measured, as were the shape, size, location, and intensity of the phosphenes. Adverse events were also assessed.Stimulation of all contacts resulted in phosphene perception. Phosphenes appeared completely or partially in the left hemifield. Stimulation of the electrodes below the calcarine sulcus elicited phosphenes in the superior hemifield and vice versa. Changing the stimulation parameters of frequency, pulse width, and burst duration affected current thresholds for eliciting phosphenes, and increasing the amplitude or frequency of stimulation resulted in brighter perceptions. While stimulation thresholds decreased between an average of 5% and 12% after 19 months, spatial mapping of phosphenes remained consistent over time. Although no serious adverse events were observed, the subject experienced mild headaches and dizziness in three instances, symptoms that did not persist for more than a few hours and for which no clinical intervention was required.Using an off-the-shelf neurostimulator, the authors were able to reliably generate phosphenes in different areas of the visual field over 19 months with no serious adverse events, providing preliminary proof of feasibility and safety to proceed with visual epicortical prosthetic clinical trials. Moreover, they systematically explored the relationship between stimulation parameters and phosphene thresholds and discovered the direct relation of perception thresholds based on primary visual cortex (V1) neuronal population excitation thresholds.


2020 ◽  
Vol 65 (4) ◽  
pp. 461-468
Author(s):  
Jannatul Naeem ◽  
Nur Azah Hamzaid ◽  
Amelia Wong Azman ◽  
Manfred Bijak

AbstractFunctional electrical stimulation (FES) has been used to produce force-related activities on the paralyzed muscle among spinal cord injury (SCI) individuals. Early muscle fatigue is an issue in all FES applications. If not properly monitored, overstimulation can occur, which can lead to muscle damage. A real-time mechanomyography (MMG)-based FES system was implemented on the quadriceps muscles of three individuals with SCI to generate an isometric force on both legs. Three threshold drop levels of MMG-root mean square (MMG-RMS) feature (thr50, thr60, and thr70; representing 50%, 60%, and 70% drop from initial MMG-RMS values, respectively) were used to terminate the stimulation session. The mean stimulation time increased when the MMG-RMS drop threshold increased (thr50: 22.7 s, thr60: 25.7 s, and thr70: 27.3 s), indicating longer sessions when lower performance drop was allowed. Moreover, at thr70, the torque dropped below 50% from the initial value in 14 trials, more than at thr50 and thr60. This is a clear indication of muscle fatigue detection using the MMG-RMS value. The stimulation time at thr70 was significantly longer (p = 0.013) than that at thr50. The results demonstrated that a real-time MMG-based FES monitoring system has the potential to prevent the onset of critical muscle fatigue in individuals with SCI in prolonged FES sessions.


1984 ◽  
Vol 62 (1) ◽  
pp. 153-156 ◽  
Author(s):  
Archana Chaudhry ◽  
John W. Downie ◽  
Thomas D. White

The present study was carried out to assess the possible role of ATP in the noncholinergic, nonadrenergic transmission in the rabbit urinary bladder. When rabbit detrusor muscle strips were superfused with medium containing firefly luciferin–luciferase and stimulated transmurally at low stimulation parameters, tetrodotoxin-sensitive contractions were obtained but no release of ATP could be detected. However, at somewhat higher stimulation parameters, release of ATP was observed. This release of ATP was not diminished by tetrodotoxin indicating that ATP was not likely released as a result of propagated action potentials in nerves. Because contractions persisted in the presence of tetrodotoxin, it is possible that the ATP might have been released as a result of direct electrical stimulation of the muscle. These results do not support the idea that ATP is released as a neurotransmitter in the rabbit bladder.


2019 ◽  
Vol 40 (3-4) ◽  
pp. 309-318 ◽  
Author(s):  
Mélissa Pagé ◽  
Catherine Maheux ◽  
Anick Langlois ◽  
Julyanne Brassard ◽  
Émilie Bernatchez ◽  
...  