scholarly journals 073_16804-H5 Relation Between Heart Rate Change and Recurrence After Pulmonary Vein Isolation in Patients With Paroxysmal Atrial Fibrillation

2017 ◽  
Vol 3 (10) ◽  
pp. S28
Author(s):  
Y. Sugai ◽  
K. Kumagai ◽  
K. Minami ◽  
M. Inoue ◽  
H. Motoda ◽  
...  
Author(s):  
Hui-Nam Pak ◽  
Je-Wook Park ◽  
Song-Yi Yang ◽  
Tae-Hoon Kim ◽  
Jae-Sun Uhm ◽  
...  

Background: The efficacy of cryoballoon pulmonary vein isolation (Cryo-PVI) is equivalent to that of radiofrequency pulmonary vein isolation in patients with paroxysmal atrial fibrillation (AF). We aimed to compare the efficacy and safety profile of Cryo-PVI and high-power, short-duration (HPSD) radiofrequency catheter ablation (RFCA) in patients with AF. Methods: We prospectively randomized 314 patients with paroxysmal AF (men, 71.3%; 59.9±10.9 years old) to either the Cryo-PVI group (n=156) or HPSD-RFCA group (n=158). Cavotricuspid isthmus ablation and linear ablation from the superior vena cava to the right atrial septum in addition to pulmonary vein isolation were carried out in the majority of patients in the HPSD-RFCA group. The primary end point was AF recurrence after a single procedure; secondary end points were the recurrence pattern, cardioversion rate, follow-up heart rate variability, and response to antiarrhythmic drugs. Results: After a mean follow-up of 9.8±5.1 months, the clinical recurrence rate did not significantly differ between the two groups (log-rank P =0.840). The rate of recurrence as atrial tachycardia ( P >0.999), cardioversion ( P =0.999), and 3-month heart rate variability (high frequency; P =0.506) did not significantly differ. During the final follow-up, sinus rhythm was maintained without antiarrhythmic drugs in 70.5% of the Cryo-PVI group and 73.4% of the HPSD-RFCA group ( P =0.567). No significant difference was found in the major complication rate between the two groups (3.8% versus 0.6%; P =0.066), but total procedure time was significantly shorter in the Cryo-PVI group (78.5±20.2 versus 124.5±37.1 minutes; P <0.001). Conclusions: In patients with paroxysmal AF, the Cryo-PVI is an effective rhythm-control strategy with a shorter procedure time compared with the HPSD-RFCA. Registration: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT03920917.


Author(s):  
Lisa Y. W. Tang ◽  
Nathaniel M. Hawkins ◽  
Kendall Ho ◽  
Roger Tam ◽  
Marc W. Deyell ◽  
...  

Background The natural history of autonomic alterations following catheter ablation of drug‐refractory paroxysmal atrial fibrillation is poorly defined, largely because of the historical reliance on non‐invasive intermittent rhythm monitoring for outcome ascertainment. Methods and Results The study included 346 patients with drug‐refractory paroxysmal atrial fibrillation undergoing pulmonary vein isolation using contemporary advanced‐generation ablation technologies. All patients underwent insertion of a Reveal LINQ (Medtronic) implantable cardiac monitor before ablation. The implantable cardiac monitor continuously recorded physical activity, heart rate variability (measured as the SD of the average normal‐to‐normal), daytime heart rate, and nighttime heart rate. Longitudinal autonomic data in the 2‐month period leading up to the date of ablation were compared with the period from 91 to 365 days following ablation. Following ablation there was a significant decrease in SD of the average normal‐to‐normal (mean difference versus baseline of 19.3 ms; range, 12.9–25.7; P <0.0001), and significant increases in daytime and nighttime heart rates (mean difference versus baseline of 9.6 bpm; range, 7.4–11.8; P <0.0001, and 7.4 bpm; range, 5.4–9.3; P <0.0001, respectively). Patients free of arrhythmia recurrence had significantly faster daytime (11±11 versus 8±12 bpm, P =0.001) and nighttime heart rates (8±9 versus 6±8 bpm, P =0.049), but no difference in SD of the average normal‐to‐normal ( P =0.09) compared with those with atrial fibrillation recurrence. Ablation technology and cryoablation duration did not influence these autonomic nervous system effects. Conclusions Pulmonary vein isolation results in significant sustained changes in the heart rate parameters related to autonomic function. These changes are correlated with procedural outcome and are independent of the ablation technology used. Registration URL: https://www.clinicaltrials.gov ; Unique identifier: NCT01913522.


2020 ◽  
Vol 41 (Supplement_2) ◽  
Author(s):  
A Chikata ◽  
T Kato ◽  
K Ududa ◽  
S Fujita ◽  
K Otowa ◽  
...  

Abstract Introduction Pulmonary vein isolation (PVI) affects ganglionated plexi (GP) around the atrium, leading to a modification of the intrinsic cardiac autonomic system (ANS). In animal models, GP ablation has a potential risk of QT prolongation and ventricular arrhythmias. However, the impact of PVI on QT intervals in humans remains unclear. Purpose This study aims to evaluate the Impact of PVI on QT interval in patients with paroxysmal atrial fibrillation. Methods We analyzed consecutive 117 PAF patients for their first PVI procedures. 12-lead ECG was evaluated at baseline, 4 hr, day 1, 1 month, and 3 months after ablation. Only patients with sinus rhythm on 12-lead ECG at each evaluation point without antiarrhythmic drugs were included. Results Heart rate significantly increased at 4 hr, day 1, and 1 month. Raw QT interval prolonged at 4 hr (417.1±41.6 ms, P&lt;0.001) but shortened at day 1 (376.4±34.1 ms, P&lt;0.001), 1 month (382.2±31.5 ms, P&lt;0.001), and 3 months (385.1±32.8 ms, P&lt;0.001) compared to baseline (391.6±31.4 ms). Bazett- and Fridericia- corrected QTc intervals significantly prolonged at 4hr (Bazett: 430.8±27.9 ms, P&lt;0.001; Fridericia: 425.8±27.4 ms, P&lt;0.001), day1 (Bazett: 434.8±22.3 ms, P&lt;0.001; Fridericia: 414.1±23.7 ms, P&lt;0.001), 1M (Bazett: 434.8±22.3 ms, P&lt;0.001; Fridericia: 408.2±21.0 ms, P&lt;0.05), and 3M (Bazett: 420.1±21.8 ms, P&lt;0.001; Fridericia: 407.8±21.1 ms, P&lt;0.05) compared to baseline (Bazett: 404.9±25.2 ms; Fridericia: 400.0±22.6 ms). On the other hand, Framingham- and Hodges- corrected QTc interval significantly prolonged only at 4hr (Framingham: 424.1±26.6 ms, P&lt;0.001; Hodges: 426.8±28.4 ms, P&lt;0.001) and at day1 (Framingham: 412.3±29.3 ms, P&lt;0.01; Hodges: 410.6±40.2 ms, P&lt;0.05) compared to baseline (Framingham: 399.2±22.7 ms; Hodges: 400.7±22.8 ms). At 4 hr after ablation, raw QT and QTc of all formulas significantly prolonged than baseline. Raw QT and QTc prolongation at 4hr after ablation were more frequently observed in female patients. Multiple regression analysis revealed that female patient is a significant predictor of raw QT and QTc interval prolongation of all formulas 4hr after PVI. Conclusions Raw QT and QTc prolonged after PVI, especially in the acute phase. Female patient is a risk factor for QT prolongation in the acute phase after PVI. Funding Acknowledgement Type of funding source: None


EP Europace ◽  
2020 ◽  
Author(s):  
Michelle Lycke ◽  
Maria Kyriakopoulou ◽  
Milad El Haddad ◽  
Jean-Yves Wielandts ◽  
Gabriela Hilfiker ◽  
...  

Abstract Aims Catheter ablation of paroxysmal atrial fibrillation (AF) reduces AF recurrence, AF burden, and improves quality of life. Data on clinical and procedural predictors of arrhythmia recurrence are scarce and are flawed by the high rate of pulmonary vein reconnection evidenced during repeat procedures after pulmonary vein isolation (PVI). In this study, we identified clinical and procedural predictors for AF recurrence 1 year after CLOSE-guided PVI, as this strategy has been associated with an increased PVI durability. Methods and results Patients with paroxysmal AF, who received CLOSE-guided PVI and who participated in a prospective trial in our centre, were included in this study. Uni- and multivariate models were plotted to find clinical and procedural predictors for AF recurrence within 1 year. Three hundred twenty-five patients with a mean age of 63 years (CHA2DS2VASc 1 [1–3], left atrium diameter 41 ± 6 mm) were included. About 60.9% were male individuals. After 1 year, AF recurrence occurred in 10.5% of patients. In a binary logistic regression analysis, the diagnosis-to-ablation time (DAT) was found to be the strongest predictor of AF recurrence (P = 0.011). Diagnosis-to-ablation time ≥1 year was associated with a nearly two-fold increased risk for developing AF recurrence. Conclusion The DAT is the most important predictor of arrhythmia recurrence in low-risk patients treated with durable pulmonary vein isolation for paroxysmal AF. Whether reducing the DAT could improve long-term outcomes should be investigated in another trial.


Sign in / Sign up

Export Citation Format

Share Document