Synthesis and luminescence characteristics of Tb3+-doped fluorophosphate glass for UV detection

2021 ◽  
Vol 572 ◽  
pp. 121012
Author(s):  
Kaiyu Tao ◽  
Yumian Ye ◽  
Huizhong Bai ◽  
Shuangbao Wang
2020 ◽  
Vol 16 ◽  
Author(s):  
Bathinapatla Ayyappa ◽  
Suvardhan Kanchi ◽  
Myalowenkosi I. Sabela ◽  
Krishna Bisetty

BACKGROUND: Sucralose is a high intensity artificial sweetener sucralose and chemically known as 1,6-dichloro-1,6-dideoxy-β-D-fructofuranosyl-4-chloro-4-deoxy-α-D-galactopyranoside. It is used as a sweetener and flavour enhancer in foods and beverages. Due to its high stability at wider temperatures and pH, made its applicability in various food products throughout the world. As per Joint FAO/WHO Expert Group on Food Additives (JECFA) in 1990, the daily intake of sucralose is 0-15 mg/kg body weight. The literature reports suggest that sucralose has a possible health threat due to the presence of chlorine groups, thereby leading to the several illnesses. The growing interest on the use of SUC in the foods, makes it necessary in developing a fast, reliable, cost effective and reproducible analytical method to determine SUC in food samples. The detection of sucralose and other carbohydrates like fructose, glucose and sucrose is a challenging task owing to its: (i) unavailability of the charged functions and (ii) lack of absorption of strong chromophoric nature in the UV region. Therefore, separation of non-absorbing neutral molecules needs a careful procedure with the suitable electrolyte systems. METHODOLOGY: An indirect UV detection capillary electrophoretic method is described for the separation of sucralose in different food samples. It was achieved by nucleophile substitution (SN2) in the presence of amine as background electrolytes. The morpholine buffer showed good buffering capacity in terms of migration time (< 8.0 min) and baseline stability when compared to other amine buffers (ethylamine, piperidine, triethylamine). The analytical applications of proposed method showed by recovery percentages of sucralose in real and spiked samples on intra and inter-day basis at optimum experimental conditions of 0.2 M buffer concentration and pH 12.0 at 230 nm UV detection. RESULTS: The selection of BGE, UV detection wavelength, buffer concentration, buffer pH, cassette temperature and applied voltage were optimized to enhance the sensitivity and selectivity of the separation method. Recoveries obtained were ranging from 96.87 to 98.82 % for real samples and 94.45 to 98.06 % for spiked samples respectively. Linearity was studied in the range of 2-10 mM, and showed a correlation coefficients of 0.9942 with LOD and LOQ found to be 0.3804 mg L-1 and 1.5215 mg L-1 with % RSD (n = 5) ± 1.27 and 1.19 % with respect to migration time and peak area. Furthermore, to better understand the separation of sucralose with amine buffers were investigated computationally using HOMO-LUMO calculations. The obtained results showed that the band gap decreases in the presence of amine moiety irrespective of its nature. CONCLUSION: In the study, novel background electrolytic system was successfully applied to separate sucralose using indirect UV detector with capillary electrophoresis. The FT-IR results confirmed that the interaction of sucralose with different amine buffers to better understand the separation chemistry behind sucralose and amine complexes. Moreover, computational results indicate that the direction of charge transfer from the amine functionality to the glucofuranosyl ring in each amine derivative of sucralose confirms the strong interaction between sucralose and amines, which led in the baseline separation of sucralose in different food samples.


2020 ◽  
Vol 16 (3) ◽  
pp. 277-286
Author(s):  
Amal A. El-Masry ◽  
Mohammed E. A. Hammouda ◽  
Dalia R. El-Wasseef ◽  
Saadia M. El-Ashry

Background: The first highly sensitive, rapid and specific green microemulsion liquid chromatographic (MELC) method was established for the simultaneous estimation of fluticasone propionate (FLU) and azelastine HCl (AZL) in the presence of their pharmaceutical dosage form additives (phenylethyl alcohol (PEA) and benzalkonium chloride (BNZ)). Methods: The separation was performed on a C18 column using (o/w) microemulsion as a mobile phase which contains 0.2 M sodium dodecyl sulphate (SDS) as surfactant, 10% butanol as cosurfactant, 1% n-octanol as internal phase and 0.3% triethylamine (TEA) adjusted at pH 6 by 0.02 M phosphoric acid; with UV detection at 220 nm and programmed with flow rate of 1 mL/min. Results: The validation characteristics e.g. linearity, lower limit of quantification (LOQ), lower limit of detection (LOD), accuracy, precision, robustness and specificity were investigated. The proposed method showed linearity over the concentration range of (0.5-25 µg/mL) and (0.1-25 µg/mL) for FLU and AZL, respectively. Besides that, the method was adopted in a short chromatographic run with satisfactory resolution factors of (2.39, 3.78 and 6.74 between PEA/FLU, FLU/AZL and AZL/BNZ), respectively. The performed method was efficiently applied to pharmaceutical nasal spray with (mean recoveries ± SD) (99.80 ± 0.97) and (100.26 ± 0.96) for FLU and AZL, respectively. Conclusion: The suggested method was based on simultaneous determination of FLU and AZL in the presence of PEA and BNZ in pure form, laboratory synthetic mixture and its combined pharmaceutical dosage form using green MELC technique with UV detection. The proposed method appeared to be superior to the reported ones of being more sensitive and specific, as well as the separation was achieved with good performance in a relatively short analysis time (less than 7.5 min). Highly acceptable values of LOD and % RSD make this method superior to be used in quality control laboratories with of HPLC technique.


2021 ◽  
pp. 2100023
Author(s):  
Kong‐Chao Shen ◽  
Jing‐Kun Wang ◽  
Yang Shen ◽  
Yan‐Qing Li ◽  
Ming‐Lei Guo ◽  
...  

Author(s):  
Yuan Ma ◽  
Haiqin Su ◽  
Zhijun Zhang ◽  
Rui Wan ◽  
Shengwu Li ◽  
...  

2021 ◽  
Vol 60 (3) ◽  
pp. 1480-1490
Author(s):  
Shi-Ping Wang ◽  
Yuan Li ◽  
Zhi-Xiang Zhang ◽  
Yu Zhang ◽  
Yu Wang ◽  
...  

2020 ◽  
Vol 18 (1) ◽  
pp. 377-390
Author(s):  
Dina El Sherbiny ◽  
Mary E. K. Wahba

AbstractA stability-indicating hybrid micelle liquid chromatography accompanied by UV detection was developed for the simultaneous analysis of either paracetamol (PCA) or pseudoephedrine hydrochloride (PSU) with their synthetic impurities. Mixture I contains PCA with p-amino phenol and p-nitro phenol, while mixture II involves the estimation of PSU with benzaldehyde and benzoic acid. Both mixtures were separated using a C18 column that was thermostatically maintained at 40°C and operating under a flow rate of 1.5 mL/min, applying UV detection at 240 nm for mixture I and 220 nm for mixture II. In both cases, the mobile phase consisted of 0.1 M sodium dodecyl sulfate, acetonitrile, and triethylamine (90:10:0.3, v/v/v) and adjusted to pH 4 (mixture I) or pH 3.7 (mixture II) using 2.0 M O-phosphoric acid. The proposed method was validated and successfully applied to assay different pharmaceuticals containing PCA or PSU. Moreover, the stability-indicating nature of the proposed method was proved through applying photolytic degradation procedures for PCA.


2021 ◽  
Vol 557 ◽  
pp. 120504
Author(s):  
Dongwei Zhang ◽  
Xin Xu ◽  
Tianlai Yu ◽  
Dahong Mo ◽  
Jinlong Diao ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document