Punching shear strength of interior concrete slab-column connections reinforced with FRP flexural and shear reinforcement

2021 ◽  
pp. 103692
Author(s):  
Gia Toai Truong ◽  
Kyoung-Kyu Choi ◽  
Chang-Soo Kim
2002 ◽  
Vol 29 (4) ◽  
pp. 602-611 ◽  
Author(s):  
Ehab F El-Salakawy ◽  
Maria Anna Polak ◽  
Khaled A Soudki

The paper presents work on punching shear rehabilitation and strengthening of existing slab–column connections. Four full-scale specimens representing slab–column edge connections were built and tested to failure. Three slabs were then repaired and strengthened and tested again. In the originally tested slabs, which were chosen for repair, one slab had an opening in front of the column and contained shear reinforcement, one slab had an opening and no shear reinforcement, and one had no opening and no reinforcement. The dimensions of the slabs were 1540 × 1020 × 120 mm with square columns (250 × 250 mm). The openings in the specimens were square (150 × 150 mm) with the sides parallel to the sides of the column. The slabs were made using normal weight concrete (28-day average compressive strength of 32 MPa) and reinforced with a reinforcement ratio of 0.75%. The slabs were repaired by replacing old-damaged concrete with new concrete of the same properties. Strengthening was carried out using shear studs for the two slabs, which originally did not have shear reinforcement. The rehabilitation increased the punching shear strength (by 26–41%) and the ductility of the connections. All repaired specimens failed in flexure.Key words: concrete slabs, punching shear, rehabilitation, edge connections, openings, studs, repair.


2021 ◽  
Vol 11 (6) ◽  
pp. 2736
Author(s):  
Min Sook Kim ◽  
Young Hak Lee

In this study, the structural behavior of reinforced concrete flat plates shear reinforced with vertical grids made of a glass fiber reinforced polymer (GFRP) was experimentally evaluated. To examine the shear strength, experiments were performed on nine concrete slabs with different amounts and spacings of shear reinforcement. The test results indicated that the shear strength increased as the amount of shear reinforcement increased and as the spacing of the shear reinforcement decreased. The GFRP shear reinforcement changed the cracks and failure mode of the specimens from a brittle punching to flexure one. In addition, the experimental results are compared with a shear strength equation provided by different concrete design codes. This comparison demonstrates that all of the equations underestimate the shear strength of reinforced concrete flat plates shear reinforced with GFRP vertical grids. The shear strength of the equation by BS 8110 is able to calculate the punching shear strength reasonably for a concrete flat plate shear reinforced with GFRP vertical grids.


Author(s):  
Dominic Joray ◽  
Martin Diggelmann

<p>The reinforced concrete slab of the reconstructed Station Square in Berne needed to be strengthened against punching shear. The case study led to the application of a newly developed post-installed punching shear reinforcement with inclined bonded bars.</p>


2019 ◽  
Vol 5 (3) ◽  
pp. 528 ◽  
Author(s):  
Maroua Mohammed Majeed ◽  
Aamer Najim Abbas

This paper presents an experimental investigation on the punching shear strength of reinforced concrete flat plate slabs with shearhead collars. Eight reinforced concrete slab specimens were casted and tested under static load test, the load was applied at the center of slab by 100x100 mm steel column. The effect of the shapes, diameter and number of stiffeners has been discovered for shearheads through studying its effect on the load-deflection behavior, ultimate capacity, cracking load, failure mode, stiffness, ductility and energy absorption of tested specimens. The experimental results indicates that using square shearhead had achieved a slight increase in punching shear strength about 3% over that circular shearhead using the same surface area. Also, utilize 550 mm shearhead diameter will contribute to increase the punching shear strength about 14.5%. The increase in the number of stiffeners in specimen (CS4) had reduced the ultimate punching shear capacity by 20.3% over reference specimen. The first crack was decreased from 12.5kN to 7.5kN, when increases the number of stiffeners from one to two. The cracking load was increased with the increase of the diameter of circular shearhead from 10kN to 15Kn in specimens of 336mm and 550mm respectively. The specimen with 336mm diameter and 30mm height circular shearhead achieved 427 kN.m energy absorption, it is higher than the energy absorption of reference specimen by 2.6%. Also, using two stiffeners improved the energy absorption by 110.2% higher than the specimen with one stiffener.


2019 ◽  
Vol 10 (1) ◽  
pp. 265 ◽  
Author(s):  
Cheng-Chih Chen ◽  
Shun-Long Chen

This study presents the structural behavior and punching shear strength of the concrete slab-column connections strengthened with carbon fiber reinforced polymer (CFRP) laminates. The variables considered for the twelve specimens included the compressive strength of the concrete, the ratio of the tensile steel reinforcement, and the amount of the CFRP laminates. Square concrete slabs were simply supported along four edges. During the test, monotonically concentrated load was applied to the stub column located at the center of the slab. The punching shear strength, stiffness, and mode of failure were investigated. Test results demonstrated that increasing the compressive strength of concrete, ratio of the steel reinforcement, and amount of the CFRP laminates led to an increase in the punching shear strength of the slabs. Moreover, the CFRP laminates were effective in appreciably increasing the punching shear strength of the slab-column connections. An analytical approach was conducted to calculate the punching shear strength of the slab-column connections strengthened with CFRP laminates. Based on the theory of reinforced concrete members, the application of the CFRP laminates increased the flexural strength of the slab and resulted in an increase of the effective depth of the slab section. Consequently, the punching shear strength was increased. The results of the analytical calculation revealed that the analytical work accurately predicted the experimental punching shear strength.


2018 ◽  
Vol 33 ◽  
pp. 02007 ◽  
Author(s):  
Valery Filatov

The article presents the methodology and results of an analytical study of structural parameters influence on the value of punching force for the joint of columns and flat reinforced concrete slab. This design solution is typical for monolithic reinforced concrete girderless frames, which have a wide application in the construction of high-rise buildings. As the results of earlier studies show the punching shear strength of slabs at rectangular columns can be lower than at square columns with a similar length of the control perimeter. The influence of two structural parameters on the punching strength of the plate is investigated - the ratio of the side of the column cross-section to the effective depth of slab C/d and the ratio of the sides of the rectangular column Cmax/Cmin. According to the results of the study, graphs of reduction the control perimeter depending on the structural parameters are presented for columns square and rectangular cross-sections. Comparison of results obtained by proposed approach and MC2010 simplified method are shown, that proposed approach gives a more conservative estimate of the influence of the structural parameters. A significant influence of the considered structural parameters on punching shear strength of reinforced concrete slabs is confirmed by the results of experimental studies. The results of the study confirm the necessity of taking into account the considered structural parameters when calculating the punching shear strength of flat reinforced concrete slabs and further development of code design methods.


2014 ◽  
Vol 627 ◽  
pp. 245-248
Author(s):  
Hyun Ki Choi

The punching shear on the flat plate slab-column connection can bring about the reason of the brittle punching shear failure which may result of collapsing the whole structure. From the development of residential flat plate system, the shear reinforcement is developed for preventing the punching shear. This study proposed 3 reinforcements that are increased to bond capacity using lateral bar, the structure test is performed. As performed test result, because slabs not keep enough bond length, slab is failed before shear reinforcement's yield strength duo to anchorage of slip. According to result, FEM analyzed an effect of slab thickness and concrete compressive. The study suggests shear strength formula that possible a positive shear reinforcement in slab-column connection.


Sign in / Sign up

Export Citation Format

Share Document