A biomechanical comparison of new techniques for distal clavicular fracture repair versus locked plating

2019 ◽  
Vol 28 (5) ◽  
pp. 982-988 ◽  
Author(s):  
Gautam P. Yagnik ◽  
Paul C. Brady ◽  
Joseph P. Zimmerman ◽  
Charles J. Jordan ◽  
David A. Porter
2019 ◽  
Vol 58 (5) ◽  
pp. 916-919
Author(s):  
Rachel M. Randall ◽  
Tara Nagle ◽  
Andrew Steckler ◽  
Damien Billow ◽  
Mark J. Berkowitz

2018 ◽  
Vol 2018 ◽  
pp. 1-6 ◽  
Author(s):  
Onur Balaban ◽  
Turan Cihan Dülgeroğlu ◽  
Tayfun Aydın

Objective. We aim to report our experiences regarding the implementation of the ultrasound-guided combined interscalene-cervical plexus block (CISCB) technique as a sole anesthesia method in clavicular fracture repair surgery. Materials and Methods. Charts of patients, who underwent clavicular fracture surgery through this technique, were reviewed retrospectively. We used an in-plane ultrasound-guided single-insertion, double-injection combined interscalene-cervical plexus block technique. During the performance of each block, the block areas were visualized by using a linear transducer, and the needles were advanced by using the in-plane technique. Block success and complication rates were evaluated. Results and Discussion. 12 patients underwent clavicular fracture surgery. Surgical regional anesthesia was achieved in 100% of blocks. None of the patients necessitated conversion to general anesthesia during surgery. There were no occurrences of acute complications. Conclusions. The ultrasound-guided combined interscalene-cervical plexus block was a successful and effective regional anesthesia method in clavicular fracture repair. Prospective comparative studies would report the superiority of the regional technique over general anesthesia.


Injury ◽  
2013 ◽  
Vol 44 (10) ◽  
pp. 1340-1345 ◽  
Author(s):  
Soroush Assari ◽  
Alan Kaufmann ◽  
Kurosh Darvish ◽  
Jung Park ◽  
Jonathan Haw ◽  
...  

2005 ◽  
Vol 18 (04) ◽  
pp. 220-226 ◽  
Author(s):  
J. M. Manos ◽  
A. S. Orlansky ◽  
R. J. Todhunter ◽  
E. J. Trotter ◽  
M. C. H. van der Meulen ◽  
...  

SummaryThe locking compression plate (LCP) supports biological osteosynthesis by functioning as an internal fixator, rather than as a full or limited contact bone plate which must be adequately contoured and affixed directly to the bone for stable internal fixation of the fracture. In order to help justify the use of the LCP in our veterinary patients, in vitro biomechanical testing was performed comparing the LCP to the conventional limited contact dynamic compression plate (LC-DCP) in canine femurs. We hypothesized that the LCP construct would be at least as stiff under bending and torsional loads as the LC-DCP. The LCP and LC-DCP were applied over a 20-mm osteotomy gap to contralateral bones within each pair of 14 femora. Non-destructive four-point bending and torsion, and cyclical testing in torsion were performed. The constructs were then loaded to failure in torsion. In medial-lateral and lateral-medial structural bending, significant differences were not found between the LCP and LC-DCP, however, at the gap, the LCP construct was stiffer than the LC-DCP in lateral-medial bending. Significant differences in behaviour over time were not noted between the plate designs during cyclical testing. When loading the constructs to failure in internal rotation, the LC-DCP failed at a significantly lower twist angle (P = .0024) than the LCP. Based on the similar performance with loading, the locking compression plate is a good alternative implant for unstable diaphyseal femoral fracture repair in dogs.


1962 ◽  
Vol 11 (02) ◽  
pp. 137-143
Author(s):  
M. Schwarzschild

It is perhaps one of the most important characteristics of the past decade in astronomy that the evolution of some major classes of astronomical objects has become accessible to detailed research. The theory of the evolution of individual stars has developed into a substantial body of quantitative investigations. The evolution of galaxies, particularly of our own, has clearly become a subject for serious research. Even the history of the solar system, this close-by intriguing puzzle, may soon make the transition from being a subject of speculation to being a subject of detailed study in view of the fast flow of new data obtained with new techniques, including space-craft.


Author(s):  
M.A. Parker ◽  
K.E. Johnson ◽  
C. Hwang ◽  
A. Bermea

We have reported the dependence of the magnetic and recording properties of CoPtCr recording media on the thickness of the Cr underlayer. It was inferred from XRD data that grain-to-grain epitaxy of the Cr with the CoPtCr was responsible for the interaction observed between these layers. However, no cross-sectional TEM (XTEM) work was performed to confirm this inference. In this paper, we report the application of new techniques for preparing XTEM specimens from actual magnetic recording disks, and for layer-by-layer micro-diffraction with an electron probe elongated parallel to the surface of the deposited structure which elucidate the effect of the crystallographic structure of the Cr on that of the CoPtCr.XTEM specimens were prepared from magnetic recording disks by modifying a technique used to prepare semiconductor specimens. After 3mm disks were prepared per the standard XTEM procedure, these disks were then lapped using a tripod polishing device. A grid with a single 1mmx2mm hole was then glued with M-bond 610 to the polished side of the disk.


Sign in / Sign up

Export Citation Format

Share Document