Assessment of IgM enzyme immunoassay and IgG avidity assay for distinguishing between primary and secondary immune response to rubella vaccine

2005 ◽  
Vol 130 (1-2) ◽  
pp. 59-65 ◽  
Author(s):  
Rasool Hamkar ◽  
Somayeh Jalilvand ◽  
Talat Mokhtari-Azad ◽  
Keramat Nouri Jelyani ◽  
Hosein Dahi-Far ◽  
...  
2004 ◽  
Vol 11 (1) ◽  
pp. 119-122 ◽  
Author(s):  
Cláudio S. Pannuti ◽  
Ricardo José Morello ◽  
José Cássio de Moraes ◽  
Suely Pires Curti ◽  
Ana Maria S. Afonso ◽  
...  

ABSTRACT Despite almost universal use of measles vaccines in recent decades, epidemics of the disease continue to occur. Understanding the role of primary vaccine failure (failure to seroconvert after vaccination) and secondary vaccine failures (waning immunity after seroconversion) in measles epidemics is important for the evaluation of measles control programs in developing countries. After a measles epidemic in São Paulo, Brazil, 159 cases previously confirmed by detection of specific immunoglobulin M (IgM) antibodies were tested for IgG avidity, and a secondary immune response, defined by an IgG avidity index of at least 30%, was established in 30 of 159 (18.9%) patients. Among the 159 patients, 107 (67.3%) had not been vaccinated and 52 (32.7%) had received one or more doses of measles vaccine. Of the 107 unvaccinated patients, 104 (97.2%) showed a primary immune response, defined as an IgG avidity index of less than 30%. Among the 52 patients with documented vaccination, 25 (48.1%) showed a primary immune response and 27 (51.9%) showed a secondary immune response, thereby constituting a secondary vaccine failure. Primary vaccine failure was observed in 13 of 13 patients vaccinated prior to 1 year of age and in 43.5 and 12.5%, respectively, of patients receiving one or two doses after their first birthdays. These results provide evidence that measurement of IgG avidity can be used to distinguish between primary and secondary vaccine failures in vaccinated patients with measles; the method can also be a useful tool for the evaluation of measles control programs.


2009 ◽  
Vol 15 (1) ◽  
pp. 94-103 ◽  
Author(s):  
R. Hamkar ◽  
S. Jalilvand ◽  
M.H. Abdol Baghi ◽  
K.N. Jelyani ◽  
A. Esteghamati ◽  
...  

2012 ◽  
Vol 19 (11) ◽  
pp. 1810-1817 ◽  
Author(s):  
Sara Mercader ◽  
Philip Garcia ◽  
William J. Bellini

ABSTRACTIn regions where endemic measles virus has been eliminated, diagnostic assays are needed to assist in correctly classifying measles cases irrespective of vaccination status. A measles IgG avidity assay was configured using a commercially available measles-specific IgG enzyme immunoassay by modifying the protocol to include three 5-min washes with diethylamine (60 mM; pH 10.25) following serum incubation; serum was serially diluted, and the results were expressed as the end titer avidity index. Receiver operating characteristic analysis was used for evaluation and validation and to establish low (≤30%) and high (≥70%) end titer avidity thresholds. Analysis of 319 serum specimens expected to contain either high- or low-avidity antibodies according to clinical and epidemiological data indicated that the assay is highly accurate, with an area under the curve of 0.998 (95% confidence interval [CI], 0.978 to 1.000), sensitivity of 91.9% (95% CI, 83.2% to 97.0%), and specificity of 98.4% (95% CI, 91.6% to 100%). The assay is rapid (<2 h) and precise (standard deviation [SD], 4% to 7%). In 18 samples from an elimination setting outbreak, the assay identified 2 acute measles cases with low-avidity results; both were IgM-positive samples. Additionally, 11 patients (15 samples) with modified measles who were found to have high-avidity IgG results were classified as secondary vaccine failures; one sample with an intermediate-avidity result was not interpretable. In elimination settings, measles IgG avidity assays can complement existing diagnostic tools in confirming unvaccinated acute cases and, in conjunction with adequate clinical and epidemiologic investigation, aid in the classification of vaccine failure cases.


Blood ◽  
2002 ◽  
Vol 99 (1) ◽  
pp. 83-87 ◽  
Author(s):  
Clarisse M. Machado ◽  
Flávio B. Gonçalves ◽  
Cláudio S. Pannuti ◽  
Frederico L. Dulley ◽  
Vanda A. U. F. de Souza

In 1997, a measles outbreak was identified in São Paulo. Between February and December, 20 185 cases were confirmed. From April to July 1997, a seroepidemiologic survey was conducted to identify the recipients of bone marrow (BM) transplants who were susceptible to measles and the occurrence of measles in this population. A total of 156 patients were screened by enzyme immunoassay (EIA). Patients with IgG titers more than 100 mIU/mL were considered immune. Measles reimmunization records were also reviewed. Thirty-two vaccinated patients underwent serologic evaluation. Six of 22 patients (27.3%) within 3 years after vaccination lost measles immunity, in contrast to 7 of 10 patients (70%) vaccinated longer than 3 years previously (P = .049). Among the 122 nonvaccinated patients, 41 (33.6%) were susceptible to measles: 4 of 47 patients (8.5%) within the first year after BM transplantation (BMT), and 37 of the 75 patients (49.3%) after the first year after BMT (P &lt; .001). Eight recipients acquired measles, confirmed by serology (EIA). High-avidity IgG antibodies were observed in the acute phase of measles, suggesting a secondary immune response. Measles interstitial pneumonia was observed in one patient. Seven patients had mild symptoms. Exanthema was present in all patients. All but one patient had fever and nonproductive cough. Koplik spots could be observed in 5 patients. Measles can be mild in BM transplant recipients. Exanthema is frequently present but not often typical. Immunity to measles decreases after day +365 after BMT. Additional studies are needed to evaluate the safety of measles vaccine after the first year of BMT, mostly during outbreaks.


1983 ◽  
Vol 158 (2) ◽  
pp. 529-545 ◽  
Author(s):  
D A Nemazee ◽  
V L Sato

A/J mice were found to produce autoreactive IgM anti-IgG1 in response to secondary immunization with a number of protein antigens. No anti-IgG1 was produced after a single such immunization, indicating that antigen: IgG1 antibody complexes were responsible for inducing the autoreactive response. The size of the anti-IgG1 response was in some cases massive and of the same order of magnitude as the response to the foreign immunizing material. No significant anti-IgG2a, anti-IgG2b, or anti-IgG3 response was found in mice producing anti-IgG1. Virtually all of the anti-IgG1 material produced was of the IgM class and bound to the Fc region of autologous IgG1. A component of the anti-IgG1 was shown to be able to distinguish between the two mouse IgG1 allotypes. These results suggest that self-reactive anti-IgG is a common component of the secondary immune response of mice that may have powerful physiological and immunoregulatory effects.


Sign in / Sign up

Export Citation Format

Share Document