Incidence, temporal trends and potential risk factors for aseptic loosening following primary unicompartmental knee arthroplasty: A meta-analysis of 96,294 knees

The Knee ◽  
2021 ◽  
Vol 31 ◽  
pp. 28-38
Author(s):  
Matthew C. Barrett ◽  
Florence O. Wilkinson ◽  
Ashley W. Blom ◽  
Michael R. Whitehouse ◽  
Setor K. Kunutsor
2019 ◽  
Vol 33 (02) ◽  
pp. 180-189 ◽  
Author(s):  
Giuseppe Gianluca Costa ◽  
Mirco Lo Presti ◽  
Alberto Grassi ◽  
Giuseppe Agrò ◽  
Sergio Cialdella ◽  
...  

AbstractLong-term results of unicompartmental knee arthroplasty (UKA) have shown a slightly higher revision rate than total knee arthroplasty (TKA), and implant fixation geometry seems to affect prosthetic survivorship. Whether metal-backed tibial component leads to superior performance over the all-polyethylene design is unclear, and a lack of evidence exists in literature. Our purpose was to demonstrate which implant design of UKA (all-polyethylene or metal-backed tibial component) is clinically superior regarding revision rates and clinical functioning, and investigate the role of potential factors that could affect the revision rate. A systematic review was conducted for clinical studies comparing all-polyethylene and metal-backed tibial components used in primary UKAs in terms of revision rates and clinical scores. Meta-regression techniques were used to explore factors modifying the observed effect. All causes of revision were extracted and analyzed, to find statistically significant differences between the two groups. Our research strategy generated a systematic review of nine studies comprising 1,101 UKAs in 1,088 patients with 87 revisions for any reason. Meta-analysis showed a higher, but not statistically significant, risk of aseptic revision in the all-polyethylene group. Studies with a smaller sample size and higher percentage of female patients were correlated to a higher relative risk of revision in favor of all-polyethylene UKAs. Differently, patients' age and duration of follow-up did not influence the risk ratio. The main cause for revision was aseptic loosening in both implants' component, with no statistically differences in the two groups examined. Our results do not show a superiority of the metal-backed tibial component in UKAs in terms of survivorship, although extreme care must be given for patients with high risk of early failure, such as female patients. However, surgical experience, in combination with careful patient selection, remains paramount and may lead to better long-term outcomes in patients requiring UKA. This is a Level III, therapeutic study.


Author(s):  
Joost A. Burger ◽  
Tjeerd Jager ◽  
Matthew S. Dooley ◽  
Hendrik A. Zuiderbaan ◽  
Gino M. M. J. Kerkhoffs ◽  
...  

Abstract Purpose (I) To determine the incidence of periprosthetic tibial fractures in cemented and cementless unicompartmental knee arthroplasty (UKA) and (II) to summarize the existing evidence on characteristics and risk factors of periprosthetic fractures in UKA. Methods Pubmed, Cochrane and Embase databases were comprehensively searched. Any clinical, laboratory or case report study describing information on proportion, characteristics or risk factors of periprosthetic tibial fractures in UKA was included. Proportion meta-analysis was performed to estimate the incidence of fractures only using data from clinical studies. Information on characteristics and risk factors was evaluated and summarized. Results A total of 81 studies were considered to be eligible for inclusion. Based on 41 clinical studies, incidences of fractures were 1.24% (95%CI 0.64–2.41) for cementless and 1.58% (95%CI 1.06–2.36) for cemented UKAs (9451 UKAs). The majority of fractures in the current literature occurred during surgery or presented within 3 months postoperatively (91 of 127; 72%) and were non-traumatic (95 of 113; 84%). Six different fracture types were observed in 21 available radiographs. Laboratory studies revealed that an excessive interference fit (press fit), excessive tibial bone resection, a sagittal cut too deep posteriorly and low bone mineral density (BMD) reduce the force required for a periprosthetic tibial fracture to occur. Clinical studies showed that periprosthetic tibial fractures were associated with increased body mass index and postoperative alignment angles, advanced age, decreased BMD, female gender, and a very overhanging medial tibial condyle. Conclusion Comparable low incidences of periprosthetic tibial fractures in cementless and cemented UKA can be achieved. However, surgeons should be aware that an excessive interference fit in cementless UKAs in combination with an impaction technique may introduce an additional risk, and could therefore be less forgiving to surgical errors and patients who are at higher risk of periprosthetic tibial fractures. Level of evidence V.


2021 ◽  
Vol 23 ◽  
pp. 128-137
Author(s):  
Haowen Kwan ◽  
Kendrick To ◽  
Christine Bojanic ◽  
Karl Romain ◽  
Wasim Khan

2019 ◽  
Vol 34 (7) ◽  
pp. 1538-1545 ◽  
Author(s):  
Braiden M. Heaps ◽  
Jason L. Blevins ◽  
Yu-Fen Chiu ◽  
Joseph F. Konopka ◽  
Shaun P. Patel ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document