Distortion correction of EPI data using multimodal nonrigid registration with an anisotropic regularization

2016 ◽  
Vol 34 (2) ◽  
pp. 127-136 ◽  
Author(s):  
Daniel Glodeck ◽  
Jürgen Hesser ◽  
Lei Zheng
2008 ◽  
Vol 62 (suppl_1) ◽  
pp. ONS209-ONS216 ◽  
Author(s):  
Neculai Archip ◽  
Olivier Clatz ◽  
Stephen Whalen ◽  
Simon P. DiMaio ◽  
Peter M. Black ◽  
...  

Abstract Objective: Preoperative magnetic resonance imaging (MRI), functional MRI, diffusion tensor MRI, magnetic resonance spectroscopy, and positron-emission tomographic scans may be aligned to intraoperative MRI to enhance visualization and navigation during image-guided neurosurgery. However, several effects (both machine- and patient-induced distortions) lead to significant geometric distortion of intraoperative MRI. Therefore, a precise alignment of these image modalities requires correction of the geometric distortion. We propose and evaluate a novel method to compensate for the geometric distortion of intraoperative 0.5-T MRI in image-guided neurosurgery. Methods: In this initial pilot study, 11 neurosurgical procedures were prospectively enrolled. The scheme used to correct the geometric distortion is based on a nonrigid registration algorithm introduced by our group. This registration scheme uses image features to establish correspondence between images. It estimates a smooth geometric distortion compensation field by regularizing the displacements estimated at the correspondences. A patient-specific linear elastic material model is used to achieve the regularization. The geometry of intraoperative images (0.5 T) is changed so that the images match the preoperative MRI scans (3 T). Results: We compared the alignment between preoperative and intraoperative imaging using 1) only rigid registration without correction of the geometric distortion, and 2) rigid registration and compensation for the geometric distortion. We evaluated the success of the geometric distortion correction algorithm by measuring the Hausdorff distance between boundaries in the 3-T and 0.5-T MRIs after rigid registration alone and with the addition of geometric distortion correction of the 0.5-T MRI. Overall, the mean magnitude of the geometric distortion measured on the intraoperative images is 10.3 mm with a minimum of 2.91 mm and a maximum of 21.5 mm. The measured accuracy of the geometric distortion compensation algorithm is 1.93 mm. There is a statistically significant difference between the accuracy of the alignment of preoperative and intraoperative images, both with and without the correction of geometric distortion (P < 0.001). Conclusion: The major contributions of this study are 1) identification of geometric distortion of intraoperative images relative to preoperative images, 2) measurement of the geometric distortion, 3) application of nonrigid registration to compensate for geometric distortion during neurosurgery, 4) measurement of residual distortion after geometric distortion correction, and 5) phantom study to quantify geometric distortion.


Author(s):  
M.F. Schmid ◽  
R. Dargahi ◽  
M. W. Tam

Electron crystallography is an emerging field for structure determination as evidenced by a number of membrane proteins that have been solved to near-atomic resolution. Advances in specimen preparation and in data acquisition with a 400kV microscope by computer controlled spot scanning mean that our ability to record electron image data will outstrip our capacity to analyze it. The computed fourier transform of these images must be processed in order to provide a direct measurement of amplitudes and phases needed for 3-D reconstruction.In anticipation of this processing bottleneck, we have written a program that incorporates a menu-and mouse-driven procedure for auto-indexing and refining the reciprocal lattice parameters in the computed transform from an image of a crystal. It is linked to subsequent steps of image processing by a system of data bases and spawned child processes; data transfer between different program modules no longer requires manual data entry. The progress of the reciprocal lattice refinement is monitored visually and quantitatively. If desired, the processing is carried through the lattice distortion correction (unbending) steps automatically.


Forests ◽  
2021 ◽  
Vol 12 (4) ◽  
pp. 464
Author(s):  
Wenjie Zhang ◽  
Tianzhong Zhao ◽  
Xiaohui Su ◽  
Baoguo Wu ◽  
Zhiqiang Min ◽  
...  

Stem analysis is an essential aspect in forestry investigation and forest management, as it is a primary method to study the growth law of trees. Stem analysis requires measuring the width and number of tree rings to ensure the accurate measurement, expand applicable tree species, and reduce operation cost. This study explores the use of Open Source Computer Vision Library (Open CV) to measure the ring radius of analytic wood disk digital images, and establish a regression equation of ring radius based on image geometric distortion correction. Here, a digital camera was used to photograph the stem disks’ tree rings to obtain digital images. The images were preprocessed with Open CV to measure the disk’s annual ring radius. The error correction model based on the least-square polynomial fitting method was established for digital image geometric distortion correction. Finally, a regression equation for tree ring radius based on the error correction model was established. Through the above steps, click the intersection point between the radius line and each ring to get the pixel distance from the ring to the pith, then the size of ring radius can be calculated by the regression equation of ring radius. The study’s method was used to measure the digital image of the Chinese fir stem disk and compare it with the actual value. The results showed that the maximum error of this method was 0.15 cm, the average error was 0.04 cm, and the average detection accuracy reached 99.34%, which met the requirements for measuring the tree ring radius by stem disk analysis. This method is simple, accurate, and suitable for coniferous and broad-leaved species, which allows researchers to analyze tree ring radius measurement, and is of great significance for analyzing the tree growth process.


Sign in / Sign up

Export Citation Format

Share Document