Comparison between dual-energy x-ray absorptiometry and bioelectrical impedance for body composition measurements in adults with chronic kidney disease: A cross-sectional, longitudinal, multi-treatment analysis

Nutrition ◽  
2021 ◽  
Vol 82 ◽  
pp. 111059 ◽  
Author(s):  
Natália Tomborelli Bellafronte ◽  
Luisa Maria Diani ◽  
Lorena Vega-Piris ◽  
Guillermina Barril Cuadrado ◽  
Paula Garcia Chiarello
2020 ◽  
Vol 35 (Supplement_3) ◽  
Author(s):  
Natália Tomborelli Bellafronte ◽  
Lorena Vega-Piris ◽  
Paula Garcia Chiarello ◽  
Guillermina Barril Cuadrado

Abstract Background and Aims Chronic kidney disease (CKD) patients frequently have an altered body composition driven by metabolic disorders from the uremic syndrome that usually leads to increased protein catabolism, with obesity and muscle impairment being common conditions associated with worse clinical prognosis and high mortality rates. Therefore, with increased mortality and disability rates of CKD patients in the last quarter of a century and the association of a poor body composition with low survival, routine and longitudinal assessment of body composition could improve clinical outcomes. Due to limited availability of reference methods to assess nutritional status, alternative methods are used. In view of the above, our goal was to evaluate the agreement between multifrequency bioelectrical impedance spectroscopy (BIS) and Dual-energy X-ray Absorptiometry (DXA) for assessment of body composition in CKD. Method Cross-sectional and prospective analyses by DXA (Hologic, GE®) and BIS (BCM, Fresenius Medical Care®) in whole-body (BISWB) and segmental (BISSEG) protocols were performed in CKD non-dialysis-dependent, hemodialysis and peritoneal dialysis (for at least 3 months), and renal transplantation (for at least 6 months) adult (18 ≤ age ≤ 60 years old) patients. Measurements were performed consecutively by the same professional after an 8-hour fast, drainage of the peritoneal dialysate and just after the midweek hemodialysis session. Intraclass correlation coefficient (ICC) and Bland-Altman plots were evaluated for agreement analysis in group and individual levels, respectively; linear regression analysis was performed for bias assessment and development of new equations; ROC curve was constructed for diagnosis of inadequate error tolerance (DXA - BIS > ± 2kg). Results A total of 266 patients were included: 137 men (M) and 129 women (W); 81 were in non-dialysis-dependent treatment, 83 in hemodialysis, 24 in peritoneal dialysis, and 80 had renal transplantation. Total sample had a mean age of 47 ± 10 years old. CKD was secondary to systemic arterial hypertension in 29% of the total sample, to glomerulonephritis in 25%, to diabetes mellitus in 10%, to polycystic kidney in 7%, to glomerulosclerosis and systemic syndromes in 8%, and to other causes and unknown etiology in 20%. Fourteen patients (4 M and 10 W) were in automated and 9 (4 M and 5 W) in continuous ambulatory PD. KTx was by living donor in 18 (14 M and 4 W) and by deceased donor in 63 (34 M and 29 W) patients. The agreement with DXA was greater for BISWB than BISSEG; for fat mass (FM) (ICC in M = 0.89; ICC in W = 0.93) than for fat free mass (FFM) (ICC in M = 0.57; ICC in W = 0.52). Bland-Altman plots showed high limits of agreement (FFM: from -9.51 to 15.64kg; FM: from -7.71 to 7.32kg) with greater bias for FFM as muscular mass increases and for FM in extremes of body fat. The agreement was lower when using the prospective data (body change analysis) (ICC for FFM in M = 0.20; ICC for FFM in W = 0.49; ICC for FM in M = 0.46; ICC for FM in W = 0.58). The factors that interfered in bias between methods were extra to intracellular water ratio (ECW/ICW), body mass index, fat mass index, waist circumference, resistance and reactance (adjusted r2 for FFM = 0.90; r2 for FM = 0.87). FFM had poorer agreement in the last tertile of ECW/ICW sample (ICC in M = 0.69, 0.68 and 0.51; ICC in W = 0.71, 0.74 and 0.38 for first, second and third tertiles, respectively). An ECW/ICW cut-off point of > 0.725 for inadequate error tolerance was determined. New prediction equations for FFM (r2 = 0.91) and FM (r2 = 0.89) presented adequate error tolerance in 55% and 63% in the validation sample compared to 30% and 39% of the original equation, respectively. Conclusion For body composition evaluation in CKD, BIS applied using the whole-body protocol, in normal hydration CKD patients is as reliable as DXA; BIS must be used with caution among overhydrated patients with ECW/ICW > 0.725. The newly developed equations are indicated for greater precision.


2018 ◽  
Vol 2018 ◽  
pp. 1-11 ◽  
Author(s):  
Kulapong Jayanama ◽  
Supanee Putadechakun ◽  
Praopilad Srisuwarn ◽  
Sakda Arj-Ong Vallibhakara ◽  
Prapimporn Chattranukulchai Shantavasinkul ◽  
...  

Background. Body composition measurement is very important for early nutritional care in hemodialysis patients. Dual-energy X-ray absorptiometry (DXA) is a gold standard test, but clinically limited. Bioelectrical impedance analysis (BIA) with multifrequency technique is a practical and reliable tool. Objective. This cross-sectional study was aimed to compare the agreement of BIA with DXA in measurement of body composition in hemodialysis patients and to evaluate their associated factors. Methods. Body composition was measured by 2 BIA methods (InBody S10 and InBody 720) and DXA after a hemodialysis session. A total of 69 measurements were included. Pearson’s correlation and Bland and Altman analysis were used to determine the correlation of body composition between methods and to compare the methods agreement, respectively. Results. The correlation coefficients of body compositions were strong between DXA and InBody S10 (fat mass index (FMI): r=0.95, fat-free mass index (FFMI): r=0.78) and also between DXA and InBody 720 (FMI: r=0.96, FFMI: r=0.81). Comparing to DXA, the means of each body composition measured by InBody S10 method were not significantly different in each gender, but differences were found in FM, %FM, and FMI measured by InBody 720. Conclusions. In maintenance hemodialysis patients, the measurement of body composition with DXA and both BIA methods had highly significant correlations; practically, BIA method could be used as an instrument to follow FM and FFM and to measure the edematous stage. Further studies with large populations are warranted.


2004 ◽  
Vol 19 (9) ◽  
pp. 2289-2295 ◽  
Author(s):  
C. M. Avesani ◽  
S. A. Draibe ◽  
M. A. Kamimura ◽  
M. Cendoroglo ◽  
A. Pedrosa ◽  
...  

2018 ◽  
Author(s):  
Carla M Prado ◽  
Camila LP Oliveira ◽  
M Cristina Gonzalez ◽  
Steven B Heymsfield

Body composition assessment is an important tool in both clinical and research settings able to characterize the nutritional status of individuals in various physiologic and pathologic conditions. Health care professionals can use the information acquired by body composition analysis for the prevention and treatment of diseases, ultimately improving health status. Here we describe commonly used techniques to assess body composition in healthy individuals, including dual-energy x-ray absorptiometry, bioelectrical impedance analysis, air displacement plethysmography, and ultrasonography. Understanding the key underlying concept(s) of each assessment method, as well as its advantages and limitations, facilitates selection of the method of choice and the method of the compartment of interest. This review contains 5 figures, 3 tables and 52 references Key words: air displacement plethysmography, bioelectrical impedance analysis, body composition, disease, dual-energy x-ray absorptiometry, health, muscle mass, nutritional status, obesity, sarcopenia, ultrasound fat mass


Sign in / Sign up

Export Citation Format

Share Document