Preparation and migration study of graphene oxide-grafted polymeric microspheres: EOR implications

2020 ◽  
Vol 192 ◽  
pp. 107286
Author(s):  
Dai-jun Du ◽  
Wan-fen Pu ◽  
Sheng Zhang ◽  
Fa-yang Jin ◽  
Sheng-kui Wang ◽  
...  
Author(s):  
Zhiqiang Huang ◽  
Manman Sun ◽  
Yanyi Li ◽  
Zhenzhao Guo ◽  
Hong Li

A conductive fibrous scaffold with typical aligned topography is beneficial for the adhesion, proliferation, NGF secretion and migration of Schwann cells under electrical stimulation.


2019 ◽  
Vol 6 (5) ◽  
pp. 299-309 ◽  
Author(s):  
Shuang Ge ◽  
Yadong Xi ◽  
Ruolin Du ◽  
Yuzhen Ren ◽  
Zichen Xu ◽  
...  

Abstract In this study, we designed a double layer-coated vascular stent of 316L stainless steel using an ultrasonic spray system to achieve both antiproliferation and antithrombosis. The coating included an inner layer of graphene oxide (GO) loaded with docetaxel (DTX) and an outer layer of carboxymethyl chitosan (CMC) loaded with heparin (Hep). The coated surface was uniform without aggregation and shedding phenomena before and after stent expanded. The coating treatment was able to inhibit the adhesion and activation of platelets and the proliferation and migration of smooth muscle cells, indicating the excellent biocompatibility and antiproliferation ability. The toxicity tests showed that the GO/DTX and CMC/Hep coating did not cause deformity and organ abnormalities in zebrafish under stereomicroscope. The stents with GO double-layer coating were safe and could effectively prevent thrombosis and in-stent restenosis after the implantation into rabbit carotid arteries for 4–12 weeks.


2020 ◽  
Vol 2020 ◽  
pp. 1-6
Author(s):  
Min Zhao ◽  
Xianhui Li ◽  
Di Zhang ◽  
Longshan Zhao

Objective. To establish a method for extraction and determination of antioxidant 264 (2,6-di-tert-butyl-4-methylphenol) in the brominated butyl rubber stopper for injection and migration study in recombinant potent antitumor and antivirus protein injection (Novaferon). Methods. Dichloromethane-ethanol was adopted as the extraction solvent during the process of reflux extraction of antioxidant 264 in the brominated butyl rubber stopper. High-performance liquid chromatography (HPLC) was used for the determination of the migration of antioxidant 264 to Novaferon. The mobile phase consisted of acetonitrile-water (80 : 20, v/v). The flow rate was 1.5 mL/min. The detection wavelength was 280 nm. Results. The linearity range was from 4.003 to 200.150 μg/mL (r2 = 0.99996), and the average recovery of antioxidant 264 was 97.8%. The applicability of the methodology was good, which can be used for the determination of antioxidant 264. The results indicated that antioxidant 264 was not detected in Novaferon after the accelerated test and three months of long-term test. Conclusion. The established validated method in this study can be used for the determination of antioxidant 264 in the rubber stopper, and the brominated butyl rubber stopper has good compatibility with Novaferon.


2012 ◽  
Vol 28 (3) ◽  
pp. 307-317 ◽  
Author(s):  
Joshua A. Wood ◽  
Dai-Jung Chung ◽  
Shin Ae Park ◽  
Allison L. Zwingenberger ◽  
Christopher M. Reilly ◽  
...  

Nanoscale ◽  
2017 ◽  
Vol 9 (13) ◽  
pp. 4578-4592 ◽  
Author(s):  
Gregor Žerjav ◽  
Muhammad Shahid Arshad ◽  
Petar Djinović ◽  
Ita Junkar ◽  
Janez Kovač ◽  
...  

A graphical illustration of TNR + rGO composites and a possible mechanism for improved charge migration.


Sign in / Sign up

Export Citation Format

Share Document