CuO nanosheets-enhanced flow-injection chemiluminescence system for determination of vancomycin in water, pharmaceutical and human serum

Author(s):  
A.R. Khataee ◽  
A. Hasanzadeh ◽  
M. Iranifam ◽  
M. Fathinia ◽  
Y. Hanifehpour ◽  
...  
2012 ◽  
Vol 2012 ◽  
pp. 1-5
Author(s):  
Jiangman Liu ◽  
Huan Yang ◽  
Yun Zhang ◽  
Min Wu ◽  
Haixiang Zhao ◽  
...  

A sensitive chemiluminescence (CL) method, based on the inhibitory effect of roxithromycin (ROX) on the CL reaction between luminol and dissolved oxygen in a flow-injection system, was first proposed for the determination of ROX at picogram levels. The decrement of CL intensity was linearly proportional to the logarithm of ROX concentrations ranging from 0.1 to 100 pg mL-1, giving the limit of detection (LOD) of 0.03 pg mL-1 (3σ). At a flow rate of 2.0 mL min-1, a complete analytical procedure including sampling and washing could be performed within 0.5 min, with relative standard deviations (RSDs) of less than 5.0% (n=5). The proposed procedure was applied successfully to the determination of ROX in pharmaceutical, human serum, and urine with the recoveries ranging from 90.0 to 110.0%.


Luminescence ◽  
2012 ◽  
Vol 28 (3) ◽  
pp. 407-411 ◽  
Author(s):  
Wenwen Liu ◽  
Liangxiao Xie ◽  
Hongshuang Liu ◽  
Shichao Xu ◽  
Bingcheng Hu ◽  
...  

2013 ◽  
Vol 2013 ◽  
pp. 1-7 ◽  
Author(s):  
Jiajia Wang ◽  
Xijuan Tan ◽  
Zhenghua Song

Based on the inhibitory effect of uric acid (UA) on luminol-Co2+chemiluminescence (CL) system, a sensitive method for the determination of UA at nanomolar level by flow injection (FI) CL was proposed. The proposed method was successfully applied to real-time monitoring of UA excretion in human 24 h urine with different food intake, showing that meats, vegetables, and porridge intake caused differential UA excretions of 879, 798, and 742 mg, respectively. It was also found that UA concentrations in urine under the three kinds of food intake simultaneously reached maximum at 2 h after meals with the values of 417, 318, and 288 μg mL−1, respectively. The UA concentration in human serum was also determined by this approach, and the possible mechanism of luminol-Co2+-UA CL reaction was discussed in detail.


2012 ◽  
Vol 2012 ◽  
pp. 1-5
Author(s):  
Jiajia Wang ◽  
Xijuan Tan ◽  
Xin Li ◽  
Jiangman Liu ◽  
Zhenghua Song

A sensitive chemiluminescence (CL) method for the determination of hesperetin at nanogram levels was first presented. It was based on the inhibitory effect of hesperetin on luminol-dissolved oxygen CL reaction in a flow injection system. The decrements of CL intensity were logarithm over the concentrations of hesperetin in a range of 0.5 to 1000 ng mL−1, with a detection limit of 0.2 ng mL−1 (3σ) and the relative standard deviations lower than 2.1%. At a flow rate of 2.0 mL min−1, the whole determining performance including sampling and washing could be accomplished in 30 s, giving a sampling efficiency of 120 h−1. The proposed method was applied successfully to the direct hesperetin determination in human serum with recoveries from 97.0 to 106.6%, and indirect hesperidin quantification in 2.5 g pericarpium citri reticulatae showing that the content is 8.1±0.2%. The possible CL mechanism of luminol-dissolved oxygen-hesperetin reaction was also discussed in detail.


Sign in / Sign up

Export Citation Format

Share Document