Corrections for variable plasma parameters in laser induced breakdown spectroscopy: Application on archeological samples

2016 ◽  
Vol 122 ◽  
pp. 103-113 ◽  
Author(s):  
V. Lazic ◽  
A. Trujillo-Vazquez ◽  
H. Sobral ◽  
C. Márquez ◽  
A. Palucci ◽  
...  
2016 ◽  
Vol 2016 ◽  
pp. 1-6
Author(s):  
Abdolhamed Shahedi ◽  
Esmaeil Eslami ◽  
Mohammad Reza Nourani

This study is devoted to tracing and identifying the elements available in bone sample using Laser-Induced Breakdown Spectroscopy (LIBS). The bone samples were prepared from the thigh of laboratory rats, which consumed 325.29 g/mol lead acetate having 4 mM concentration in specified time duration. About 76 atomic lines have been analyzed and we found that the dominant elements are Ca I, Ca II, Mg I, Mg II, Fe I, and Fe II. Temperature curve and bar graph were drawn to compare bone elements of group B which consumed lead with normal group, group A, in the same laboratory conditions. Plasma parameters including plasma temperature and electron density were determined by considering Local Thermodynamic Equilibrium (LTE) condition in the plasma. An inverse relationship has been detected between lead absorption and elements like Calcium and Magnesium absorption comparing elemental values for both the groups.


2021 ◽  
Vol 19 (10) ◽  
pp. 01-07
Author(s):  
M.H. Asmaa ◽  
Sami A. Habana

Electron thickness and temperature of laser prompted Iron plasma boundaries, among different boundaries, were estimated. Plasma was delivered through the connection of high pinnacle power Nd: YAG laser at the key frequency of 1064 nm with a pellet target contains a limited quantity of lipstick from nearby business sectors. Lines from Fe II at 238.502 nm, Fe II at 254.904 nm, Fe II at 262.370 nm, Fe II at 286.545 nm and Fe I at 349.779 nm were utilized to assess the plasma boundaries. The current investigation was completed to assess electron temperature (Te), electron thickness (ne), plasma recurrence, Debye length and Debye number (ND). Laser-incited breakdown spectroscopy LIBS method was used for examining and deciding ghastly discharge lines. ID of change lines from all spectra was completed by contrasting ghostly lines and NIST nuclear data set.


2017 ◽  
Vol 35 (1) ◽  
pp. 159-169 ◽  
Author(s):  
H. Iftikhar ◽  
S. Bashir ◽  
A. Dawood ◽  
M. Akram ◽  
A. Hayat ◽  
...  

AbstractThe effect of the transverse magnetic field on laser-induced breakdown spectroscopy and surface modifications of germanium (Ge) has been investigated at various fluences. Ge targets were exposed to Nd: YAG laser pulses (1064 nm, 10 ns, 1 Hz) at different fluences ranging from 3 to 25.6 J/cm2 to generate Ge plasma under argon environment at a pressure of 50 Torr. The magnetic field of strength 0.45 Tesla perpendicular to the direction of plasma expansion was employed by using two permanent magnets. The emission spectra of laser-induced Ge plasma was detected by the laser-induced breakdown spectroscopy system. The electron temperature and number density of Ge plasma are evaluated by using the Boltzmann plot and stark broadening methods, respectively. The variations in emission intensity, electron temperature (Te), and number density (ne) of Germanium plasma are explored at various fluences, with and without employment of the magnetic field. It is observed that the magnetic field is responsible for significant enhancement of both excitation temperature and number density at all fluences. It is revealed that an excitation temperature increases from Te,max,without B = 16,190 to Te,max,with B = 20,123 K. Similarly, the two times enhancement in the electron density is observed from ne,max,without B = 2 × 1018 to ne,max,with B = 4 × 1018 cm−3. The overall enhancement in Ge plasma parameters in the presence of the magnetic field is attributed to the Joule heating effect and adiabatic compression. With increasing fluence both plasma parameters increase and achieve their maxima at a fluence of 12.8 J/cm2 and then decrease. In order to correlate the plasma parameters with surface modification, scanning electron microscope analysis of irradiated Ge was performed. Droplets and cones are formed for both cases. However, the growth of ridges and distinctness of features is more pronounced in case of the absence of the magnetic field; whereas surface structures become more diffusive in the presence of the magnetic field.


2014 ◽  
Vol 2014 ◽  
pp. 1-5 ◽  
Author(s):  
Emanuela Grifoni ◽  
Stefano Legnaioli ◽  
Marco Lezzerini ◽  
Giulia Lorenzetti ◽  
Stefano Pagnotta ◽  
...  

Laser-induced breakdown spectroscopy (LIBS) data are characterized by a strong dependence on the acquisition time after the onset of the laser plasma. However, time-resolved broadband spectrometers are expensive and often not suitable for being used in portable LIBS instruments. In this paper we will show how the analysis of a series of LIBS spectra, taken at different delays after the laser pulse, allows the recovery of time-resolved spectral information. The comparison of such spectra is presented for the analysis of an aluminium alloy. The plasma parameters (electron temperature and number density) are evaluated, starting from the time-integrated and time-resolved spectra, respectively. The results are compared and discussed.


ISRN Optics ◽  
2012 ◽  
Vol 2012 ◽  
pp. 1-8 ◽  
Author(s):  
Sreedhar Sunku ◽  
Ashwin Kumar Myakalwar ◽  
Manoj Kumar Gundawar ◽  
Prem Kiran Paturi ◽  
Surya Praksh Tewari ◽  
...  

We describe our results obtained from stoichiometric ratio studies of three different energetic, inorganic samples (ammonium perchlorate (AP), boron potassium nitrate (BPN), and ammonium nitrate (AN)) using the technique of laser-induced breakdown spectroscopy (LIBS) with nanosecond pulses. Signal collection was independently executed using both gated and nongated spectrometers. The oxygen peak at 777.31 nm (O) and nitrogen peaks at 742.50 nm (N1), 744.34 nm (N2), and 746.91 nm (N3) were used for evaluating the O/N ratios. Temporal analysis of plasma parameters and ratios was carried out for the gated data. O/N1, O/N2, and O/N3 ratios retrieved from the gated AP data were in excellent agreement with the actual stoichiometry. In the case of gated BPN data, O/N2 and O/N3 ratios were in good agreement. The stoichiometry results obtained with nongated spectrometer, although less accurate than that obtained with gated spectrometer, suggest that it can be used in applications where fair accuracy is sufficient. Our results strongly indicate that non-gated LIBS technique is worthwhile in the kind of applications where precision classification is not required.


2017 ◽  
Vol 35 (3) ◽  
pp. 492-504 ◽  
Author(s):  
K. Zehra ◽  
S. Bashir ◽  
S.A. Hassan ◽  
Q.S. Ahmed ◽  
M. Akram ◽  
...  

AbstractThe effect of nature and pressure of ambient environment on laser-induced breakdown spectroscopy (LIBS) and ablation mechanisms of silicon (Si) have been investigated. A Q-switched Nd-YAG laser with the wavelength of 1064 nm, pulse duration of 10 ns, and pulsed energy of 50 mJ was employed. Si targets were exposed under ambient environments of inert gases of argon, neon, and helium for different pressures ranging from 5 to 760 torr. The influence of nature and pressure of ambient gases on the emission intensity of Si plasma have been explored by using the LIBS spectrometer system. The plasma parameters such as electron temperature and number density were determined by applying Boltzmann plot and Stark broadening method, respectively. Our experimental results suggest that the nature and pressure of ambient environment play a significant role for generation, recombination, and expansion of plasma and consequently affect the excitation temperature as well as electron density of plasma. The surface morphological analysis of laser-irradiated Si was performed by using scanning electron microscope (SEM). Various kinds of structures, for example laser-induced periodic surface structures or ripples, cones, droplets, and craters have been generated and their density and size are found to be strongly dependent upon the ambient environment. A quantitative analysis of particulate size and crater depth measured from SEM images showed a strong correlation between plasma parameters and the growth of micro/nanostructures on the modified Si surface.


Sign in / Sign up

Export Citation Format

Share Document