scholarly journals Influence of Lead on the Interpretation of Bone Samples with Laser-Induced Breakdown Spectroscopy

2016 ◽  
Vol 2016 ◽  
pp. 1-6
Author(s):  
Abdolhamed Shahedi ◽  
Esmaeil Eslami ◽  
Mohammad Reza Nourani

This study is devoted to tracing and identifying the elements available in bone sample using Laser-Induced Breakdown Spectroscopy (LIBS). The bone samples were prepared from the thigh of laboratory rats, which consumed 325.29 g/mol lead acetate having 4 mM concentration in specified time duration. About 76 atomic lines have been analyzed and we found that the dominant elements are Ca I, Ca II, Mg I, Mg II, Fe I, and Fe II. Temperature curve and bar graph were drawn to compare bone elements of group B which consumed lead with normal group, group A, in the same laboratory conditions. Plasma parameters including plasma temperature and electron density were determined by considering Local Thermodynamic Equilibrium (LTE) condition in the plasma. An inverse relationship has been detected between lead absorption and elements like Calcium and Magnesium absorption comparing elemental values for both the groups.

2020 ◽  
pp. 000370282097304
Author(s):  
Amal A. Khedr ◽  
Mahmoud A. Sliem ◽  
Mohamed Abdel-Harith

In the present work, nanoparticle-enhanced laser-induced breakdown spectroscopy was used to analyze an aluminum alloy. Although LIBS has numerous advantages, it suffers from low sensitivity and low detection limits compared to other spectrochemical analytical methods. However, using gold nanoparticles helps to overcome such drawbacks and enhances the LIBS sensitivity in analyzing aluminum alloy in the current work. Aluminum was the major element in the analyzed samples (99.9%), while magnesium (Mg) was the minor element (0.1%). The spread of gold nanoparticles onto the Al alloy and using a laser with different pulse energies were exploited to enhance the Al alloy spectral lines. The results showed that Au NPs successfully improved the alloy spectral lines intensity by eight times, which could be useful for detecting many trace elements in higher matrix alloys. Under the assumption of local thermodynamic equilibrium, the Boltzmann plot was used to calculate the plasma temperature. Besides, the electron density was calculated using Mg and H lines at Mg(I) at 285.2 nm and Hα(I) at 656.2 nm, respectively. Three-dimensional contour mapping and color fill images contributed to understanding the behavior of the involved effects.


2021 ◽  
Vol 19 (10) ◽  
pp. 01-07
Author(s):  
M.H. Asmaa ◽  
Sami A. Habana

Electron thickness and temperature of laser prompted Iron plasma boundaries, among different boundaries, were estimated. Plasma was delivered through the connection of high pinnacle power Nd: YAG laser at the key frequency of 1064 nm with a pellet target contains a limited quantity of lipstick from nearby business sectors. Lines from Fe II at 238.502 nm, Fe II at 254.904 nm, Fe II at 262.370 nm, Fe II at 286.545 nm and Fe I at 349.779 nm were utilized to assess the plasma boundaries. The current investigation was completed to assess electron temperature (Te), electron thickness (ne), plasma recurrence, Debye length and Debye number (ND). Laser-incited breakdown spectroscopy LIBS method was used for examining and deciding ghastly discharge lines. ID of change lines from all spectra was completed by contrasting ghostly lines and NIST nuclear data set.


2019 ◽  
Vol 34 (12) ◽  
pp. 2378-2384 ◽  
Author(s):  
Ran Hai ◽  
Zhonglin He ◽  
Ding Wu ◽  
Weina Tong ◽  
Harse Sattar ◽  
...  

During laser ablation, the spectral emission intensity, plasma temperature and electron density increased significantly with increasing sample temperature.


2017 ◽  
Vol 35 (1) ◽  
pp. 159-169 ◽  
Author(s):  
H. Iftikhar ◽  
S. Bashir ◽  
A. Dawood ◽  
M. Akram ◽  
A. Hayat ◽  
...  

AbstractThe effect of the transverse magnetic field on laser-induced breakdown spectroscopy and surface modifications of germanium (Ge) has been investigated at various fluences. Ge targets were exposed to Nd: YAG laser pulses (1064 nm, 10 ns, 1 Hz) at different fluences ranging from 3 to 25.6 J/cm2 to generate Ge plasma under argon environment at a pressure of 50 Torr. The magnetic field of strength 0.45 Tesla perpendicular to the direction of plasma expansion was employed by using two permanent magnets. The emission spectra of laser-induced Ge plasma was detected by the laser-induced breakdown spectroscopy system. The electron temperature and number density of Ge plasma are evaluated by using the Boltzmann plot and stark broadening methods, respectively. The variations in emission intensity, electron temperature (Te), and number density (ne) of Germanium plasma are explored at various fluences, with and without employment of the magnetic field. It is observed that the magnetic field is responsible for significant enhancement of both excitation temperature and number density at all fluences. It is revealed that an excitation temperature increases from Te,max,without B = 16,190 to Te,max,with B = 20,123 K. Similarly, the two times enhancement in the electron density is observed from ne,max,without B = 2 × 1018 to ne,max,with B = 4 × 1018 cm−3. The overall enhancement in Ge plasma parameters in the presence of the magnetic field is attributed to the Joule heating effect and adiabatic compression. With increasing fluence both plasma parameters increase and achieve their maxima at a fluence of 12.8 J/cm2 and then decrease. In order to correlate the plasma parameters with surface modification, scanning electron microscope analysis of irradiated Ge was performed. Droplets and cones are formed for both cases. However, the growth of ridges and distinctness of features is more pronounced in case of the absence of the magnetic field; whereas surface structures become more diffusive in the presence of the magnetic field.


2002 ◽  
Vol 56 (4) ◽  
pp. 437-448 ◽  
Author(s):  
Jong-Il Yun ◽  
Reinhardt Klenze ◽  
Jae-Il Kim

Laser-induced breakdown spectroscopy (LIBS) is presented for the on-line multielement analysis of molten radioactive glass at a simulated vitrification process of high level liquid waste (HLLW). A plasma plume is produced by focusing the third harmonic of a Nd: YAG laser (λ = 355 nm) onto the glass melt surface at 1200 °C, and the plasma emission is guided via optical fiber and is characterized by an echelle spectrometer for the spectral range from 200 to 780 nm with a resolution of ±0.01 nm. Compared to a Czerny–Turner spectrometer, the echelle spectrometer appears distinctively superior for its broad operational spectral range and high resolution. The laser-induced plasma is found as optically thin and locally in thermodynamic equilibrium (LTE) as characterized by measuring the electron density and plasma temperature. The matrix temperature effect on the spectral emission is observed as significant, increasing the emission line intensities with increasing temperature, but differently from element to element. The applicability of LIBS is demonstrated on a laboratory scale with an inactive simulated HLLW glass melt for various analytical characteristics concerned.


2018 ◽  
Vol 3 (8) ◽  
pp. 50 ◽  
Author(s):  
Tagreed K. Hamad ◽  
Hussein Thamer Salloom

In this study, Calibration-free Laser-induced breakdown spectroscopy (CF-LIBS) was applied to quantitatively analyze the elemental composition of Ti-6Al-4V titanium based alloy samples with no need for matrix-matched calibration procedure. Nd:YAG pulsed laser operating at a wavelength of 1064 nm was focused onto the sample to generate plasma. The spectrum of plasma was recorded using spectrophotometer then compared to NIST spectral lines to determine characteristic wavelengths, energy levels and other spectroscopic parameters. The values of plasma temperature obtained using Boltzmann plot for four examined samples ranged from 7439 to 6826 K while the electron density for each element was determined using Boltzmann-Saha equation. The concentration of Ti, Al, V and Fe has been determined and were within the samples nominal concentrations obtained from XRF analysis.  The calculated average relative errors of Ti, Al, V and Fe were 0.39%, 4.38%, 4.94 % and 8.2 %, respectively. Finally, there was a direct proportionality relation between the ratio of ionic to neutral emission lines of Ti for four samples and the surface hardness values measured mechanically using Vickers hardness test. The ratio at   had the best linear regression value (R2=0.95) which indicates the best correlation with surface hardness.