Determination of organochlorine and organophosphorus pesticides in mango (Mangifera indica L.) in the State of Guerrero, Mexico

2016 ◽  
Vol 259 ◽  
pp. S222
Author(s):  
Y. Villar Encarnación ◽  
Y.A. Polanco García ◽  
M.E. Moreno Godínez ◽  
P. Álvarez Fitz ◽  
G. Huerta Beristaín ◽  
...  
2006 ◽  
Vol 6 (3) ◽  
pp. 54-56
Author(s):  
Mirjana Mijanović ◽  
Asija Začiragić

Xenobiotic solutions of different concentrations were analyzed by TLC method before and after passing trough the column with adsorbent M and compared with adsorption on the active charcoal. The efficiency of adsorption on adsorbent M was higher, compared to active charcoal. The best adsorption, in the value 90 - 100%, have shown certain organochlorine and organophosphorus pesticides, that were dissolved in non-aqueous solvents. Efficiency of adsorbent M was also proven in vivo, when solutions of tested xenobiotics before adsorption have caused death of experimental animals, and after the adsorption on adsorbent M, all treated animals have survived and had just mild symptoms of poisoning.


2000 ◽  
Vol 42 (7-8) ◽  
pp. 283-290 ◽  
Author(s):  
H.-C. Tsai ◽  
R.-A. Doong

A sol-gel based fiber-optic biosensor with acetylcholinesterase as the biorecognition element has been developed for the rapid determination of organophosphorus pesticides. Nine fluorescent indicators, acridine, acridine orange, neutral red, DAPI, rhodamine B, fluorescein, umbelliferone, FITC on celite and FITC-dextran, have been examined to optimize the fiber-optic system. Results showed that acridine and FITCs were sensitive to the change of pH value caused by the enzyme-substrate catalysis reaction. However, the sensitivity of acridine was 260 times lower than that of FITCs. Higher toxicity of acridine to acetylcholinesterase than FITC was also observed. Moreover, the high-molecular-weight FITC-dextran showed low leakage rate when immobilizing using sol-gel technology, showing that the FITC-dextran was a suitable pH sensitive fluorescent indicator for the OPPs biosensor. The response of the fiber-optic biosensor to the substrate, acetylcholine, was highly reproducible (RSD=3.5%). A good linearity of acetylcholine in the range from 0.5 to 20 mM was also obtained (R2=0.98). Furthermore, a 30% inhibition can be achieved in 30min when 152 ppb paraoxon was added into the system. The results show the possibility for real-time determination of organophosphorus pesticides by using the biosensor developed in this study.


Sign in / Sign up

Export Citation Format

Share Document