Toxicity of ionic liquid cations and anions towards activated sewage sludge organisms from different sources – Consequences for biodegradation testing and wastewater treatment plant operation

2013 ◽  
Vol 47 (9) ◽  
pp. 2921-2928 ◽  
Author(s):  
Marta Markiewicz ◽  
Magdalena Piszora ◽  
Nelson Caicedo ◽  
Christian Jungnickel ◽  
Stefan Stolte
2019 ◽  
Vol 18 (9) ◽  
pp. 2023-2034 ◽  
Author(s):  
Agnieszka A. Pilarska ◽  
Krzysztof Pilarski ◽  
Boguslawa Waliszewska ◽  
Magdalena Zborowska ◽  
Kamil Witaszek ◽  
...  

2019 ◽  
Vol 18 (1) ◽  
pp. 30-37 ◽  
Author(s):  
Mohamed N. F. Shaheen ◽  
Sahar E. Abd El-Daim ◽  
Nehal I. Ahmed ◽  
Elmahdy M. Elmahdy

Abstract Wastewater plays a major role in water pollution causing transmission of several viral pathogens, including Aichi virus (AiV) and human bocavirus (HBoV), associated with gastrointestinal illness in humans. In this study, we investigated the presence of AiV and HBoV in aquatic, sludge, sediment matrices collected from Abu-Rawash wastewater treatment plant (WWTP), El-Rahawy drain, Rosetta branch of the River Nile in Egypt by conventional polymerase chain reaction (PCR). AiV RNA was detected in 16.6% (2/12), 8.3% (1/12), 8.3% (1/12), 22% (16/72), 12.5% (3/24), 4% (1/24), and 0/24 (0%) of untreated raw sewage, treated sewage, sewage sludge, drainage water, drain sediment, river water, and river sediment, respectively. On the other hand, HBoV DNA was detected in 41.6% (5/12), 25% (3/12), 16.6% (2/12), 48.6% (35/72), 29% (7/24), 3/24 (12.5%), 4% (1/24) of untreated raw sewage, treated raw sewage, sewage sludge, drainage water, drain sediment, river water, and river sediment, respectively. This study provides data on the presence of these viruses in various types of water samples that are valuable to environmental risk assessment. In addition, the current study demonstrates the importance of environmental monitoring as an additional tool to investigate the epidemiology of AiV and HBoV circulating in a given community.


Author(s):  
Justyna Czajkowska ◽  
Piotr Nowak ◽  
Maciej Malarski ◽  
Katarzyna Pergół

This article contains the results of investigations conducted at the WULS in Warsaw concerning initial treatment of sewage sludge by means of microwave disintegration. Sewage sludge were taken from the "Mokre Łąki" wastewater treatment plant in the municipality of Izabelin. Experiments were carried out on concentrated and non-concentrated sludge. Each of the sludges was disintegrated in portions of varying volumes and also at different time of microwave interactions. Significant changes in the values of the tested parameters such as COD, turbidity and temperature due to the sludge suppression process were considered. These parameters have a significant impact on the course of further processes that treated sludge and supernatant liquid can be processed. Therefore, determining the volatility of these parameters is important.


Sign in / Sign up

Export Citation Format

Share Document