scholarly journals Electron Microscopy and Hydrodynamic Properties of Factor XIII Subunits

1989 ◽  
Vol 264 (1) ◽  
pp. 551-556
Author(s):  
N A Carrell ◽  
H P Erickson ◽  
J McDonagh
2001 ◽  
Vol 30 (6) ◽  
pp. 457-462 ◽  
Author(s):  
J. García de la Torre ◽  
O. Llorca ◽  
J. L. Carrascosa ◽  
J. M. Valpuesta

Blood ◽  
2006 ◽  
Vol 108 (6) ◽  
pp. 1919-1924 ◽  
Author(s):  
Rojin Park ◽  
Hyun-Ju Doh ◽  
Seong-Soo A. An ◽  
Jong-Rak Choi ◽  
Kwang-Hoe Chung ◽  
...  

AbstractWe report a novel fibrinogen variant (fibrinogen Seoul II), which has a heterozygous point mutation from CAA to CCA leading to AαGln328Pro. The mutation site is among several glutamine residues that serve as α-chain cross-linking acceptor sites. Fibrinogen Seoul II was found in a 51-year-old male patient and his family in Seoul, Korea. The patient was diagnosed with myocardial infarction at age 43. Eight years later he was admitted to the emergency room due to recurrence of the disease, where he expired under treatment with tissue plasminogen activator (t-PA). Fibrin polymerization curves, made using purified fibrinogen from the patient's relatives, showed a decreased final turbidity, suggesting Seoul II fibrin clots are composed of thinner fibers. This supposition was verified using scanning electron microscopy. Alpha-polymer formation by the mutant fibrinogen upon thrombin treatment in the presence of factor XIII and calcium was distinctly impaired. This result confirms that the residue Aα328 plays a pivotal role in α-chain cross-linking.


1985 ◽  
Vol 228 (1) ◽  
pp. 13-26 ◽  
Author(s):  
S J Perkins

Models for the structures of subcomponent C1q of first component C1 of human complement and its complex with subunit C1r2C1s2 are compared with experimental neutron-scattering curves. The length of the C1q collagenous arm is closer to 14.5 nm than to 11.5 nm proposed from electron microscopy, and this is consistent with the primary sequence of C1q. The mean C1q base-arm angle is 40-45 degrees and C1q is found to be flexible: the base-arm angle can vary up to 30 degrees from equilibrium at any moment. The complex of C1r2C1s2 and C1q requires a large shape change in C1r2C1s2. Ring-like models for C1r2C1s2 are not as successful at rationalizing the scattering data as are models that involve C1r2C1s2 binding to one side of C1q. Hydrodynamic calculations of the sedimentation coefficients for C1q and C1 are generally consistent with these neutron models.


Author(s):  
Shu He ◽  
Håkan Wallén ◽  
Charlotte Thålin ◽  
Jan Svensson ◽  
Margareta Blombäck

AbstractThe earliest assessment of fibrin network porosity used a liquid permeation system and confocal 3D microscopy, which was later replaced by scanning electron microscopy. Although the methods have extensively been applied in studies of health or disease, there remains debate on the choice of a proper clotting trigger. In this review, we assess published data and convey our opinions with regard to several issues. First, when the coagulation process is initiated by recombinant tissue factor (rTF) and phospholipids, the fibrin network porosity is regulated by the endogenous thrombin based on enzymatic activations of multiple coagulants. If purified thrombin (1.0 IU/mL) is employed as the clotting trigger, fibrin network porosity may be affected by exogenous thrombin, which directly polymerizes fibrinogen in plasma, and additionally by endogenous thrombin stemming from a “positive feedback loop” action of the added thrombin. Second, with use of either endogenous or exogenous thrombin, the concentration and clotting property of available fibrinogen both influence the fibrin network porosity. Third, in the assay systems in vitro, exogenous thrombin but not rTF-induced endogenous thrombin seems to be functional enough to activate factor XIII, which then contributes to a decrease in the fibrin network porosity. Fourth, fibrin network porosity determines the transport of fibrinolytic components into/through the clots and therefore serves as an indicator of the fibrinolysis potential in plasma.


Author(s):  
S. K. Aggarwal ◽  
P. McAllister ◽  
R. W. Wagner ◽  
B. Rosenberg

Uranyl acetate has been used as an electron stain for en bloc staining as well as for staining ultrathin sections in conjunction with various lead stains (Fig. 1). Present studies reveal that various platinum compounds also show promise as electron stains. Certain platinum compounds have been shown to be effective anti-tumor agents. Of particular interest are the compounds with either uracil or thymine as one of the ligands (cis-Pt(II)-uracil; cis-Pt(II)-thymine). These compounds are amorphous, highly soluble in water and often exhibit an intense blue coloration. These compounds show enough electron density to be used as stains for electron microscopy. Most of the studies are based on various cell lines (human AV, cells, human lymphoma cells, KB cells, Sarcoma-180 ascites cells, chick fibroblasts and HeLa cells) while studies on tissue blocks are in progress.


Author(s):  
Gunter F. Thomas ◽  
M. David Hoggan

In 1968, Sugimura and Yanagawa described a small 25 nm virus like particle in association with the Matsuda strain of infectious canine hepatitis virus (ICHV). Domoto and Yanagawa showed that this particle was dependent on ICHV for its replication in primary dog kidney cell cultures (PDK) and was resistant to heating at 70°C for 10 min, and concluded that it was a canine adeno-associated virus (CAAV). Later studies by Onuma and Yanagawa compared CAAV with the known human serotypes (AAV 1, 2, 3) and AAV-4, known to be associated with African Green Monkeys. Using the complement fixation (CF) test, they found that CAAV was serologically related to AAV-3 and had wide distribution in the dog population of Japan.


Author(s):  
L. D. Ackerman ◽  
S. H. Y. Wei

Mature human dental enamel has presented investigators with several difficulties in ultramicrotomy of specimens for electron microscopy due to its high degree of mineralization. This study explores the possibility of combining ion-milling and high voltage electron microscopy as a means of circumventing the problems of ultramicrotomy.A longitudinal section of an extracted human third molar was ground to a thickness of about 30 um and polarized light micrographs were taken. The specimen was attached to a single hole grid and thinned by argon-ion bombardment at 15° incidence while rotating at 15 rpm. The beam current in each of two guns was 50 μA with an accelerating voltage of 4 kV. A 20 nm carbon coating was evaporated onto the specimen to prevent an electron charge from building up during electron microscopy.


Author(s):  
P.S. Porter ◽  
T. Aoyagi ◽  
R. Matta

Using standard techniques of scanning electron microscopy (SEM), over 1000 human hair defects have been studied. In several of the defects, the pathogenesis of the abnormality has been clarified using these techniques. It is the purpose of this paper to present several distinct morphologic abnormalities of hair and to discuss their pathogenesis as elucidated through techniques of scanning electron microscopy.


Author(s):  
Douglas C. Barker

A number of satisfactory methods are available for the electron microscopy of nicleic acids. These methods concentrated on fragments of nuclear, viral and mitochondrial DNA less than 50 megadaltons, on denaturation and heteroduplex mapping (Davies et al 1971) or on the interaction between proteins and DNA (Brack and Delain 1975). Less attention has been paid to the experimental criteria necessary for spreading and visualisation by dark field electron microscopy of large intact issociations of DNA. This communication will report on those criteria in relation to the ultrastructure of the (approx. 1 x 10-14g) DNA component of the kinetoplast from Trypanosomes. An extraction method has been developed to eliminate native endonucleases and nuclear contamination and to isolate the kinetoplast DNA (KDNA) as a compact network of high molecular weight. In collaboration with Dr. Ch. Brack (Basel [nstitute of Immunology), we studied the conditions necessary to prepare this KDNA Tor dark field electron microscopy using the microdrop spreading technique.


Sign in / Sign up

Export Citation Format

Share Document