RADIATION DOSE EFFECTS IN RELATION TO OBSTETRIC X-RAYS AND CHILDHOOD CANCERS

The Lancet ◽  
1970 ◽  
Vol 295 (7658) ◽  
pp. 1185-1188 ◽  
Author(s):  
Alice Stewart ◽  
G.W Kneale
1988 ◽  
Vol 8 (1) ◽  
pp. 3-8 ◽  
Author(s):  
E A Gilman ◽  
G W Kneale ◽  
E G Knox ◽  
A M Stewart

Sensors ◽  
2021 ◽  
Vol 21 (13) ◽  
pp. 4554
Author(s):  
Ralph-Alexandru Erdelyi ◽  
Virgil-Florin Duma ◽  
Cosmin Sinescu ◽  
George Mihai Dobre ◽  
Adrian Bradu ◽  
...  

The most common imaging technique for dental diagnoses and treatment monitoring is X-ray imaging, which evolved from the first intraoral radiographs to high-quality three-dimensional (3D) Cone Beam Computed Tomography (CBCT). Other imaging techniques have shown potential, such as Optical Coherence Tomography (OCT). We have recently reported on the boundaries of these two types of techniques, regarding. the dental fields where each one is more appropriate or where they should be both used. The aim of the present study is to explore the unique capabilities of the OCT technique to optimize X-ray units imaging (i.e., in terms of image resolution, radiation dose, or contrast). Two types of commercially available and widely used X-ray units are considered. To adjust their parameters, a protocol is developed to employ OCT images of dental conditions that are documented on high (i.e., less than 10 μm) resolution OCT images (both B-scans/cross sections and 3D reconstructions) but are hardly identified on the 200 to 75 μm resolution panoramic or CBCT radiographs. The optimized calibration of the X-ray unit includes choosing appropriate values for the anode voltage and current intensity of the X-ray tube, as well as the patient’s positioning, in order to reach the highest possible X-rays resolution at a radiation dose that is safe for the patient. The optimization protocol is developed in vitro on OCT images of extracted teeth and is further applied in vivo for each type of dental investigation. Optimized radiographic results are compared with un-optimized previously performed radiographs. Also, we show that OCT can permit a rigorous comparison between two (types of) X-ray units. In conclusion, high-quality dental images are possible using low radiation doses if an optimized protocol, developed using OCT, is applied for each type of dental investigation. Also, there are situations when the X-ray technology has drawbacks for dental diagnosis or treatment assessment. In such situations, OCT proves capable to provide qualitative images.


1979 ◽  
Vol 16 (3) ◽  
pp. 299-302 ◽  
Author(s):  
C. Michel ◽  
H. Blattmann ◽  
I. Cordt-Riehle ◽  
H. Fritz-Niggli

2015 ◽  
Vol 42 (9) ◽  
pp. 5510-5516 ◽  
Author(s):  
Ashley E. Rubinstein ◽  
Zhongxing Liao ◽  
Adam D. Melancon ◽  
Michele Guindani ◽  
David S. Followill ◽  
...  

BMJ Open ◽  
2017 ◽  
Vol 7 (8) ◽  
pp. e017548 ◽  
Author(s):  
Rebecca Ward ◽  
William D Carroll ◽  
Paula Cunningham ◽  
Sheng-Ang Ho ◽  
Mary Jones ◽  
...  

ObjectivesCumulative radiation exposure is associated with increased risk of malignancy. This is important in cystic fibrosis (CF) as frequent imaging is required to monitor disease progression and diagnose complications. Previous estimates of cumulative radiation are outdated as the imaging was performed on older equipment likely to deliver higher radiation. Our objectives were to determine the radiation dose delivered to children during common radiological investigations using modern equipment and to identify the number of such investigations performed in a cohort of children with CF to calculate their cumulative radiation exposure.Design, setting and participantsData including age at investigation and radiation exposure measured as estimated effective dose (EED) were collected on 2827 radiological studies performed on children at one UK paediatric centre. These were combined with the details of all radiological investigations performed on 65 children with CF attending the same centre to enable calculation of each child’s cumulative radiation exposure.ResultsThe mean EED for the common radiological investigations varied according to age. The range was 0.01–0.02 mSv for chest X-rays, 0.03–0.11 mSv for abdominal X-rays, 0.57–1.69 mSv for CT chest, 2.9–3.9 mSv for abdominal and pelvic CT, 0.20–0.21 mSv for sinus CT and 0.15–0.52 mSv for fluoroscopy-guided procedures. The mean EED was three to five times higher for helical compared with axial chest CT scans. The mean annual cumulative EED for our cohort of children with CF was 0.15 mSv/year with an estimated cumulative paediatric lifetime EED (0–18 years) of 3.5 mSv.ConclusionsThis study provides up-to-date estimations of the radiation exposure when using common radiological investigations. These doses and the estimates of cumulative radiation exposure in children with CF are lower than previously reported. This reflects the reduced EED associated with modern equipment and the use of age-specific scanning protocols.


2021 ◽  
Author(s):  
Daniel DiCenzo DiCenzo

Gold nanoparticles (GNP) have been shown to highly absorb ionizing radiation compared to tissue. GNPs have also been shown to be high absorbers of non-ionizing radiation with a peak absorbance at a wavelength dependent on their shape and size. This study investigated radiation dose enhancement in PC3 cells when in the presence of gold nanorods (NR) and near infrared light (IR). The PC3 cells were incubated with either PEGylated NRs (PNR) or anti prostate stem cell antigen antibody with nuclear localization sequence peptide conjugated NRs (AbNR). They were exposed to near infrared light at a wavelength of 810 nm to achieve a temperature of 42 ºC to 43 ºC for 60 minutes. They were also exposed to 160 kVp x-rays. It was found that both targeted and non-targeted GNPs when exposed to radiation and near infrared light synergistically enhanced radiation dose. It was also found that AbNRs provide greater dose enhancement than PNRs.


2012 ◽  
Vol 11 (3) ◽  
pp. 195-197 ◽  
Author(s):  
Syed F. Akber

AbstractThe quality factor for x-rays, gamma rays and electrons assigned as one need to be revised. It is observed that as the energy decreases, mean lethal radiation dose (Do)decreases as well and become more potent. It is therefore proposed that radiation quality in biological systems should be assessed in the mitotic phase of the cell cycles. Furthermore, based on the mean lethal radiation dose within specific energy range, an appropriate quality factor of x-rays, gamma rays and electrons should be assigned.


2006 ◽  
Vol 53 (6) ◽  
pp. 3237-3241 ◽  
Author(s):  
J. P. Colinge ◽  
A. Orozco ◽  
J. Rudee ◽  
Weize Xiong ◽  
C. Rinn Cleavelin ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document