Localized corrosion behaviour in simulated human body fluids of commercial Ni–Ti orthodontic wires

Biomaterials ◽  
1999 ◽  
Vol 20 (8) ◽  
pp. 785-792 ◽  
Author(s):  
G Rondelli
2021 ◽  
Vol 62 (3) ◽  
pp. 213-219
Author(s):  
John Santiagu ◽  
Devadoss Delinta ◽  
Asirvatham Ajila ◽  
Annamalai Selvam ◽  
Senthamarai Muthukumaran ◽  
...  

In Modern medicine, metals and alloys are being used as implants. The Corrosion behaviour of various biomaterials under artificial body fluids are being studied. Artificial biomaterials are being implanted inside the human body to replace bone, teeth, etc. Even organs are being medically substituted with different types of metals such as mild steel, carbon steel, Ni-Cr alloy, Fe-Cr alloy, 22 carat Gold,24 carat Gold Tin, etc. due to their biocompatibility. This is achieved by connecting these metals directly with body tissues. The metals tend to corrode when it gets in contact with human body fluids. The body fluids thereby come in direct contact with tissues and the tissues are in contact with the metal thus causing the metal to corrode. And hence the corrosion resistance studies such as polarisation, AC impedance, cyclic voltammetric studies, etc, are being conducted in a medium like artificial blood plasma, artificial urine, artificial salvia, artificial sweat, Hank solution, Ringer solution, etc. The different body fluids are examined in the presence of different implantation metals by electrochemical methods and protective films are formed which are analyzed by various surface analysis techniques such as AFM, FTIR-UV, SEM, etc. The research findings will thereby be very helpful to the medical field.


1958 ◽  
Vol 10 (3) ◽  
pp. 310-318 ◽  
Author(s):  
O. K. Albrechtsen ◽  
O. Storm ◽  
M. Claassen

2017 ◽  
Vol 68 (5) ◽  
pp. 1077-1080
Author(s):  
Krisztina Martha ◽  
Alexandru Ogodescu ◽  
Cristina Ioana Bica ◽  
Cristina Molnar Varlam

Almost all orthodontic wires suffer from corrosion as they are intra-orally engaged. This chemical structure alteration appears on the surface of these wires, surface topography can be easily visualised with scanning electron microscope method. The aim of our study was to assess the intraoral corrosion of the retrieved orthodontic Ni-Ti archwires. Archwire retrieval procedure yielded approximately 30 retrieved wires, placed intra-orally for 1-5 months. SEM analysis was performed and surface changes were interpreted. Our SEM results showed, that surface corrosion and pitting can be seen on the surface of retrieved Ni-Ti wires, the depth of corrosion depends on the time wires have been engaged in the oral cavity. With regards of metal liberation consequently surface corrosion, practitioners should be avare of these chemical changes which can affect the resistence of the orthodontic appliance and patient health.


2000 ◽  
Vol 107 (1-3) ◽  
pp. 181-190 ◽  
Author(s):  
J. Röhrich ◽  
S. Zörntlein ◽  
J. Becker
Keyword(s):  

2021 ◽  
Vol 21 (1) ◽  
pp. 31-42
Author(s):  
Sphurti S Adigal ◽  
Nidheesh V Rayaroth ◽  
Reena V John ◽  
Keerthilatha M Pai ◽  
Sulatha Bhandari ◽  
...  

2013 ◽  
Vol 5 (2) ◽  
pp. 285-300 ◽  
Author(s):  
Hongwei Liang ◽  
Fei Gong ◽  
Suyang Zhang ◽  
Chen-Yu Zhang ◽  
Ke Zen ◽  
...  

Placenta ◽  
2004 ◽  
Vol 25 (7) ◽  
pp. 608-622 ◽  
Author(s):  
O Burger ◽  
E Pick ◽  
J Zwickel ◽  
M Klayman ◽  
H Meiri ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document