Resistive companion battery modeling for electric circuit simulations

2001 ◽  
Vol 93 (1-2) ◽  
pp. 186-200 ◽  
Author(s):  
B. Wu ◽  
R. Dougal ◽  
R.E. White
1978 ◽  
Vol 39 (02) ◽  
pp. 455-465 ◽  
Author(s):  
Yvonne Stirling ◽  
D J Howarth ◽  
Marguerite Vickers ◽  
W R S North ◽  
T W Meade

SummaryTwo automated methods for two-stage factor VIII assays have been compared with one another, and evaluated in practice. The Depex method records the clotting time when an electric circuit is completed by the formation of a fibrin thread across a hook-type electrode; the Electra method is based on an optical density technique of clot detection. The two methods gave comparable results for measured levels of factor VIII when haemophilic or “normal” plasmas were assayed. Results from the two methods in practice also suggest that both are valid at low and “normal” factor VIII levels. The Electra method is also probably suitable for assays of concentrates; however, the Depex method appears to give falsely high values in these circumstances, and experimental findings suggest that the reason may be that increased viscosity due to the high fibrinogen levels in factor VIII concentrates causes premature closure of the circuit between the two ends of the Depex electrode. The main advantage of the Depex method is that, provided 3 or 4 machines are available, a given number of assays can be completed more quickly than on Electra. The main advantages of Electra are that it is probably subject to less laboratory error than Depex, and that it is suitable for assaying concentrates as well as haemophilic and “normal” plasmas.


Author(s):  
V. I. Sukhanov ◽  
A. B. Grabov

The article presents some features of thin-film magnetoresistive current sensors and detectors that was developed in JSC NPO IT for noncontact current control in electric circuit aviation and cosmic electronic apparatus.


2020 ◽  
Vol 96 (3s) ◽  
pp. 295-299
Author(s):  
М.М. Гурарий ◽  
М.М. Жаров ◽  
Л.П. Ионов ◽  
И.И. Мухин ◽  
С.Г. Русаков ◽  
...  

В работе рассмотрены проблемы анализа схем ФАПЧ с учетом наличия неидеальностей в схеме частотно-фазового детектора с токовым ключом. Для снижения затрат на моделирование предложено использовать эквивалентную электрическую схему, содержащую полную принципиальную схему ЧФД и схемные эквиваленты макромоделей остальных блоков ФАПЧ. The paper considers the problems of analyzing the PLL circuit taking into account the presence of nonidealities in the phase-frequency detector with a current key. To reduce the simulation efforts, it has been proposed to apply an equivalent electric circuit containing the complete schematic diagram of the PFD and circuit equivalents of the macromodels of other PLL blocks.


Author(s):  
Aleksandr S. Serebryakov ◽  
Vladimir L. Osokin ◽  
Sergey A. Kapustkin

The article describes main provisions and relations for calculating short-circuit currents and phase currents in a three-phase traction transformer with a star-triangle-11 connection of windings, which feeds two single-phase loads in AC traction networks with a nominal voltage of 25 kilovolts. These transformers provide power to the enterprises of the agro-industrial complex located along the railway line. (Research purpose) The research purpose is in substantiating theoretical equations for digital intelligent relay protection in two-phase short circuits. (Materials and methods) It was found that since the sum of instantaneous currents in each phase is zero, each phase of the transformer works independently. We found that this significantly simplifies the task of analyzing processes with a two-phase short circuit. In this case, the problem of calculating short-circuit currents in the traction network can be simplified by reducing it to the calculation of an ordinary electric circuit with three unknown currents. (Results and discussion) The article describes equations for calculating short-circuit resistances for one phase of the transformer when connecting the secondary winding as a star or a triangle. The currents in the phases of the transformer winding at short circuit for the star-triangle-11 and star-star-with-ground schemes are compared. It was found that when calculating short-circuit currents, there is no need to convert the secondary winding of the traction transformer from a triangle to a star. (Conclusions) It was found that the results of the research can be used in the transition of relay protection systems from electromagnetic relays to modern high-speed digital devices, which will increase the operational reliability of power supply systems for traction and non-traction power consumers.


Electronics ◽  
2021 ◽  
Vol 10 (4) ◽  
pp. 475
Author(s):  
Ewa Piotrowska ◽  
Krzysztof Rogowski

The paper is devoted to the theoretical and experimental analysis of an electric circuit consisting of two elements that are described by fractional derivatives of different orders. These elements are designed and performed as RC ladders with properly selected values of resistances and capacitances. Different orders of differentiation lead to the state-space system model, in which each state variable has a different order of fractional derivative. Solutions for such models are presented for three cases of derivative operators: Classical (first-order differentiation), Caputo definition, and Conformable Fractional Derivative (CFD). Using theoretical models, the step responses of the fractional electrical circuit were computed and compared with the measurements of a real electrical system.


Sign in / Sign up

Export Citation Format

Share Document