Pressure drop, heat transfer and performance of single-phase turbulent flow in spirally corrugated tubes

2001 ◽  
Vol 24 (3-4) ◽  
pp. 131-138 ◽  
Author(s):  
Yang Dong ◽  
Li Huixiong ◽  
Chen Tingkuan
2012 ◽  
Vol 20 (04) ◽  
pp. 1250022 ◽  
Author(s):  
NORIHIRO INOUE ◽  
JUNYA ICHINOSE

An experimental study on pressure drop and heat transfer in single-phase was carried out using 10 types of internally helical-grooved and smooth small-diameter tubes with an outside diameter of 4 mm. The results are listed below: (1) In the turbulent flow region, fin height had the greatest effect, helix angle had only a minor effect, and the number of grooves had almost no effect upon the pressure drop versus the mass flow rate of the 4-mm grooved small-diameter tubes. In the laminar flow region, except for fin height, the shapes of the internal grooves had scarcely any effect upon pressure drop. (2) In the turbulent flow region, the heat transfer coefficients of the 4-mm grooved small-diameter tubes were greatly affected by fin height. The heat transfer coefficients became the maximum when a helix angle was near 15°, and there is a different tendency in the experiments of the pressure drop. On the other hand, there is almost no effect of the number of grooves. In the laminar flow region, there were no large differences in the heat transfer coefficients between the internally helical-grooved tubes and smooth small-diameter tube. (3) New empirical correlations for the friction factor and heat transfer coefficient in the laminar and turbulent flow regions were developed based on the experimental values. (4) The performance assessment in consideration of both heat transfer and pressure drop was indicated by using Colburn's analogy.


2011 ◽  
Vol 18 (6) ◽  
pp. 491-502 ◽  
Author(s):  
Andrew Mintu Sarkar ◽  
M. A. Rashid Sarkar ◽  
Mohammad Abdul Majid

2018 ◽  
Vol 140 (2) ◽  
Author(s):  
Chirag R. Kharangate ◽  
Ki Wook Jung ◽  
Sangwoo Jung ◽  
Daeyoung Kong ◽  
Joseph Schaadt ◽  
...  

Three-dimensional (3D) stacked integrated circuit (IC) chips offer significant performance improvement, but offer important challenges for thermal management including, for the case of microfluidic cooling, constraints on channel dimensions, and pressure drop. Here, we investigate heat transfer and pressure drop characteristics of a microfluidic cooling device with staggered pin-fin array arrangement with dimensions as follows: diameter D = 46.5 μm; spacing, S ∼ 100 μm; and height, H ∼ 110 μm. Deionized single-phase water with mass flow rates of m˙ = 15.1–64.1 g/min was used as the working fluid, corresponding to values of Re (based on pin fin diameter) from 23 to 135, where heat fluxes up to 141 W/cm2 are removed. The measurements yield local Nusselt numbers that vary little along the heated channel length and values for both the Nu and the friction factor do not agree well with most data for pin fin geometries in the literature. Two new correlations for the average Nusselt number (∼Re1.04) and Fanning friction factor (∼Re−0.52) are proposed that capture the heat transfer and pressure drop behavior for the geometric and operating conditions tested in this study with mean absolute error (MAE) of 4.9% and 1.7%, respectively. The work shows that a more comprehensive investigation is required on thermofluidic characterization of pin fin arrays with channel heights Hf < 150 μm and fin spacing S = 50–500 μm, respectively, with the Reynolds number, Re < 300.


2020 ◽  
Vol 142 (3) ◽  
Author(s):  
Ki Wook Jung ◽  
Eunho Cho ◽  
Hyoungsoon Lee ◽  
Chirag Kharangate ◽  
Feng Zhou ◽  
...  

Abstract High performance and economically viable cooling solutions must be developed to reduce weight and volume, allowing for a wide-spread utilization of hybrid electric vehicles. The traditional embedded microchannel cooling heat sinks suffer from high pressure drop due to small channel dimensions and long flow paths in two-dimensional (2D) plane. Utilizing direct “embedded cooling” strategy in combination with top access three-dimensional (3D) manifold strategy reduces the pressure drop by nearly an order of magnitude. In addition, it provides more temperature uniformity across large area chips and it is less prone to flow instability in two-phase boiling heat transfer. This study presents the experimental results for single-phase thermofluidic performance of an embedded silicon microchannel cold plate (CP) bonded to a 3D manifold for heat fluxes up to 300 W/cm2 using single-phase R-245fa. The heat exchanger consists of a 5 × 5 mm2 heated area with 25 parallel 75 × 150 μm2 microchannels, where the fluid is distributed by a 3D-manifold with four microconduits of 700 × 250 μm2. Heat is applied to the silicon heat sink using electrical Joule-heating in a metal serpentine bridge and the heated surface temperature is monitored in real-time by infrared (IR) camera and electrical resistance thermometry. The maximum and average temperatures of the chip, pressure drop, thermal resistance, and average heat transfer coefficient (HTC) are reported for flow rates of 0.1, 0.2. 0.3, and 0.37 L/min and heat fluxes from 25 to 300 W/cm2. The proposed embedded microchannels-3D manifold cooler, or EMMC, device is capable of removing 300 W/cm2 at maximum temperature 80 °C with pressure drop of less than 30 kPa, where the flow rate, inlet temperature, and pressures are 0.37 L/min, 25 °C and 350 kPa, respectively. The experimental uncertainties of the test results are estimated, and the uncertainties are the highest for heat fluxes &lt; 50 W/cm2 due to difficulty in precisely measuring the fluid temperature at the inlet and outlet of the microcooler.