Effect of Blood Collection Tubes on Total Triiodothyronine and Other Laboratory Assays

2006 ◽  
Vol 2006 ◽  
pp. 260-261
Author(s):  
M.G. Bissell
2005 ◽  
Vol 51 (10) ◽  
pp. 1874-1882 ◽  
Author(s):  
Raffick AR Bowen ◽  
Yung Chan ◽  
Mark E Ruddel ◽  
Glen L Hortin ◽  
Gyorgy Csako ◽  
...  

Abstract Background: A small number of immunoassays on several different types of analyzers were recently adversely affected by tube additives in Becton Dickinson (BD) Vacutainer® SST™, SST II, and Microtainer™ blood collection tubes. We examined the effect of a commonly used tube surfactant, Silwet™ L-720, on immunoassays and the mechanism for the interference. Methods: Immunoassays were performed on serum supplemented with Silwet L-720 on the IMMULITE™ 2500 and AxSYM™ analyzers. Direct effects of the surfactant on the chemiluminescent detection step of immunoassays and on antibody immobilization on the solid phase were examined. Results: Increasing the final surfactant concentration from 0 to 400 mg/L in serum significantly increased (∼51%) the apparent total triiodothyronine (TT3) concentrations measured on the IMMULITE 2500 but not the AxSYM analyzer. Several other competitive, but not noncompetitive, assays were also significantly affected by the surfactant on the IMMULITE 2500 analyzer. The effect was independent of serum components, and the surfactant had no direct effect on chemiluminescence reactions. The capture antibody, however, was displaced from the solid phase by incubation with solutions containing surfactant under conditions similar to the IMMULITE TT3 assay. Conclusions: The Silwet L-720 surfactant, which is used to coat the inner surfaces of tubes, appears to account for previously reported immunoassay interference by BD Vacutainer SST blood collection tubes. One of the mechanisms for the interference is the desorption of antibodies from the solid phase by the surfactant. The results identify an important factor in the selection of suitable blood collection tube surfactants and provide an approach for solving similar tube-assay interference problems in the future.


2005 ◽  
Vol 51 (2) ◽  
pp. 424-433 ◽  
Author(s):  
Raffick AR Bowen ◽  
Yung Chan ◽  
Joshua Cohen ◽  
Nadja N Rehak ◽  
Glen L Hortin ◽  
...  

Abstract Background: Increased total triiodothyronine (TT3) assay results in apparently euthyroid patients triggered an investigation of the effect of blood collection tubes on serum TT3 and other laboratory assays. Methods: We examined potential assay interference for three types of tubes: plastic Greiner Bio-One™ Vacuette™; glass Becton Dickinson (BD) Vacutainer™; and plastic BD Vacutainer SST™ tubes. Serum samples from apparently healthy volunteers (age range, 30–60 years; 15 males and 34 females) were collected in different tube types and analyzed in 17 immunoassays (n = 49), 30 clinical chemistry tests (n = 20), and 33 immunology assays (n = 15). Tube effects were also examined by adding pooled serum to different tube types. Results: TT3 values, when measured by the IMMULITE™ 2000 but not the AxSYM™ analyzer, were significantly higher (P <0.0001) for SST (2.81 nmol/L) than either glass (2.15 nmol/L) or Vacuette (2.24 nmol/L) tubes. The effect was large enough to substantially shift the distribution of patient values, increasing the percentage of values above the reference interval from 11.3% to 35.8%. The degree of interference from SST tubes on TT3 differed among various tube lots and could be attributed to a tube additive shared by other plastic tubes. Results from several other tests statistically differed among tube types, but differences were not considered to be clinically significant. Conclusions: Assay interferences from blood collection tubes represent challenges to clinical laboratories because they are not detected by the usual quality-control or proficiency testing programs. Laboratories can, however, address this problem by monitoring distribution of patients’ results.


2017 ◽  
Vol 19 (5) ◽  
pp. 801-804 ◽  
Author(s):  
Christina Alidousty ◽  
Danielle Brandes ◽  
Carina Heydt ◽  
Svenja Wagener ◽  
Maike Wittersheim ◽  
...  

2022 ◽  
Vol 11 (2) ◽  
pp. 320
Author(s):  
Philipp Helmer ◽  
Sebastian Hottenrott ◽  
Andreas Steinisch ◽  
Daniel Röder ◽  
Jörg Schubert ◽  
...  

Background: Anemia remains one of the most common comorbidities in intensive care patients worldwide. The cause of anemia is often multifactorial and triggered by underlying disease, comorbidities, and iatrogenic factors, such as diagnostic phlebotomies. As anemia is associated with a worse outcome, especially in intensive care patients, unnecessary iatrogenic blood loss must be avoided. Therefore, this scoping review addresses the amount of blood loss during routine phlebotomies in adult (>17 years) intensive care patients and whether there are factors that need to be improved in terms of patient blood management (PBM). Methods: A systematic search of the Medline Database via PubMed was conducted according to PRISMA guidelines. The reported daily blood volume for diagnostics and other relevant information from eligible studies were charted. Results: A total of 2167 studies were identified in our search, of which 38 studies met the inclusion criteria (9 interventional studies and 29 observational studies). The majority of the studies were conducted in the US (37%) and Canada (13%). An increasing interest to reduce iatrogenic blood loss has been observed since 2015. Phlebotomized blood volume per patient per day was up to 377 mL. All interventional trials showed that the use of pediatric-sized blood collection tubes can significantly reduce the daily amount of blood drawn. Conclusion: Iatrogenic blood loss for diagnostic purposes contributes significantly to the development and exacerbation of hospital-acquired anemia. Therefore, a comprehensive PBM in intensive care is urgently needed to reduce avoidable blood loss, including blood-sparing techniques, regular advanced training, and small-volume blood collection tubes.


2016 ◽  
Vol 49 (18) ◽  
pp. 1354-1360 ◽  
Author(s):  
Qing Kang ◽  
N. Lynn Henry ◽  
Costanza Paoletti ◽  
Hui Jiang ◽  
Pankaj Vats ◽  
...  