High-resolution scanning electron microscopy in biology

Author(s):  
Keiichi Tanaka

With the development of scanning electron microscope (SEM) with ultrahigh resolution, SEM became to play an important role in not only cytology but also molecular biology. However, the preparation methods observing tiny specimens with such high resolution SEM are not yet established.Although SEM specimens are usually coated with metals for getting electrical conductivity, it is desirable to avoid the metal coating for high resolution SEM, because the coating seriously affects resolution at this level, unless special coating techniques are used. For avoiding charging effect without metal coating, we previously reported a method in which polished carbon plates were used as substrate. In the case almost all incident electrons penetrate through the specimens and do not accumulate in them, when the specimens are smaller than 10nm. By this technique some biological macromolecules including ribosomes, ferritin, immunoglobulin G were clearly observed.Unfortunately some other molecules such as apoferritin, thyroglobulin and immunoglobulin M were difficult to be observed only by the method, because they had very low contrast and were easily damaged by electron beam.

Author(s):  
S. Saito ◽  
H. Todokoro ◽  
S. Nomura ◽  
T. Komoda

Field emission scanning electron microscope (FESEM) features extremely high resolution images, and offers many valuable information. But, for a specimen which gives low contrast images, lateral stripes appear in images. These stripes are resulted from signal fluctuations caused by probe current noises. In order to obtain good images without stripes, the fluctuations should be less than 1%, especially for low contrast images. For this purpose, the authors realized a noise compensator, and applied this to the FESEM.Fig. 1 shows an outline of FESEM equipped with a noise compensator. Two apertures are provided gust under the field emission gun.


2011 ◽  
Vol 19 (5) ◽  
pp. 22-25 ◽  
Author(s):  
Dominik Greif ◽  
Daniel Wesner ◽  
Dario Anselmetti ◽  
Jan Regtmeier

When studying highly resolved scanning electron microscope images of cell surfaces, the question arises, whether the observed patterns are real or just artifacts of the cell preparation process. The following steps are usually necessary for preparation: fixation, drying, and metal coating. Each step might introduce different artifacts. Clever techniques have been developed to dry cells as gently as possible, for example critical point drying with different organic solvents and CO2. Instrument manufacturers also have taken account of this issue, for example, through the realization of the environmental scanning electron microscope (ESEM), operating with a low-vacuum environment saturated with water so that samples might stay hydrated. Another approach is the extreme high-resolution scanning electron microscope (XHR SEM), where the electron beam is decelerated shortly before reaching the sample. This technique requires no metal coating of the sample. Cryo-SEM also may be used, where no sample preparation is required beyond freezing in a high-pressure freezer or other cryo-fixation device. Then the cell can be examined in the frozen, hydrated state using a cryostage. However, at least some kind of preparation is necessary for SEM imaging, and we wanted to find out what changes the preparation makes on the cell surface.


Author(s):  
S.R. Simmons ◽  
S.J. Eppell ◽  
R.E. Marchant ◽  
R.M. Albrecht

The atomic force microscope (AFM) has provided images at submolecular or atomic scale resolution of biological macromolecules attached to surfaces such as mica, graphite, or synthetic phospholipid membranes. Because the AFM can be operated with the sample in air, vacuum, or immersed in a liquid such as a biological buffer, it has the potential for high resolution imaging of the structure and organization of macromolecules on surfaces of cells in the hydrated or even living state. Realization of this potential would allow observation of molecular processes at the cell surface without the necessity for preparation of the sample for electron microscopy. To date, however, the AFM has yielded images of cell surfaces only at relatively low magnifications, and has not provided the atomic resolution achieved on hard, crystalline surfaces.Previously we have utilized correlative video-enhanced light microscopy, high voltage transmission electron microscopy, and low voltage, high resolution scanning electron microscopy (HRSEM)


Author(s):  
K. Ogura ◽  
S. Adachi ◽  
T. Satoh ◽  
T. Watabe ◽  
M. M. Kersker

The resolution of the SEM has been remarkably improved by means of the in-lens SEM with a field emission gun. Consequently, the thin metal coating on the specimen surface for ultra high resolution imaging has become very important. In the age of imaging with 2-3nm resolution at 100,000x magnification, a very thin platinum (Pt) coating on the specimen surface using the magnetron sputter coater has yielded successful results. However, in an ultra high resolution scanning electron microscope with better than 1nm resolution at higher than 200,000: magnification, the fine granularity of magnetron sputter coating of Inra thick Pt will be observed on the specimen surface. Therefore, a thinner metal coating with smaller grain size than that of Pt is strongly required. Recently, we tried tungsten (W) coating on many variety of specimens in argon (Ar) gas atmosphere by using a magnetron sputter coater. Using a W coated carbon film, the granularity of W was examined by both an UHR-SEM and a TEM at a minimum magnification of 250,000x.


2004 ◽  
Vol 12 (1) ◽  
pp. 45-45
Author(s):  
Robert P. Apkarian

Stephen Carmichael wrote about Cryoelectron Tomography in the May 2003 issue of Microscopy Today. Citing new preparation methods, small cells can be vitrified, observed frozen in the TEM and a series of digital images captured while the specimen is being rotated around the axis perpendicular to the electron beam producing a 3-D tomogram. Gina Sosinski and Maryann Martone wrote about imaging big and messy biological structures using cryo-electron Tomography in the July issue of Microscopy Today. Cryo-HRSEM now also seeks to provide 3-D information approaching the molecular level from frozen hydrated cell and molecular systems. Vitrification procedures for small specimens such as platelets and biomolecules on grids are accomplished by plunge freezing in liquefied etiiane as is done with cryo-TEM procedures. Bulk specimens such as organic hydrogels and tissues are routinely high pressure frozen (HPF) in 3mm gold planchets. Employing an in-lens cryostage, identical to those used in cryo-TEM, cryo-HRSEM provides 3-D high-resolution images because secondary electrons are efficiently collected above the lens in a single scan thus minimizing specimen irradiation.


Author(s):  
Etienne de Harven

Biological ultrastructures have been extensively studied with the scanning electron microscope (SEM) for the past 12 years mainly because this instrument offers accurate and reproducible high resolution images of cell shapes, provided the cells are dried in ways which will spare them the damage which would be caused by air drying. This can be achieved by several techniques among which the critical point drying technique of T. Anderson has been, by far, the most reproducibly successful. Many biologists, however, have been interpreting SEM micrographs in terms of an exclusive secondary electron imaging (SEI) process in which the resolution is primarily limited by the spot size of the primary incident beam. in fact, this is not the case since it appears that high resolution, even on uncoated samples, is probably compromised by the emission of secondary electrons of much more complex origin.When an incident primary electron beam interacts with the surface of most biological samples, a large percentage of the electrons penetrate below the surface of the exposed cells.


Author(s):  
D. Johnson ◽  
P. Moriearty

Since several species of Schistosoma, or blood fluke, parasitize man, these trematodes have been subjected to extensive study. Light microscopy and conventional electron microscopy have yielded much information about the morphology of the various stages; however, scanning electron microscopy has been little utilized for this purpose. As the figures demonstrate, scanning microscopy is particularly helpful in studying at high resolution characteristics of surface structure, which are important in determining host-parasite relationships.


Author(s):  
J. P. Langmore ◽  
N. R. Cozzarelli ◽  
A. V. Crewe

A system has been developed to allow highly specific derivatization of the thymine bases of DNA with mercurial compounds wich should be visible in the high resolution scanning electron microscope. Three problems must be completely solved before this staining system will be useful for base sequencing by electron microscopy: 1) the staining must be shown to be highly specific for one base, 2) the stained DNA must remain intact in a high vacuum on a thin support film suitable for microscopy, 3) the arrangement of heavy atoms on the DNA must be determined by the elastic scattering of electrons in the microscope without loss or large movement of heavy atoms.