Deep Chandra observations of the core of the Perseus cluster

2018 ◽  
Vol 14 (S342) ◽  
pp. 127-132
Author(s):  
Jeremy S. Sanders

AbstractThe Perseus cluster is the X-ray brightest cluster in the sky and with deep Chandra observations we are able to map its central structure on very short spatial scales. In addition, the high quality of X-ray data allows detailed spatially-resolved spectroscopy. In this paper I review what these deep observations have told us about AGN feedback in clusters, sloshing and instabilities, and the metallicity distribution.

Author(s):  
E. Brambrink ◽  
S. Baton ◽  
M. Koenig ◽  
R. Yurchak ◽  
N. Bidaut ◽  
...  

We have developed a new radiography setup with a short-pulse laser-driven x-ray source. Using a radiography axis perpendicular to both long- and short-pulse lasers allowed optimizing the incident angle of the short-pulse laser on the x-ray source target. The setup has been tested with various x-ray source target materials and different laser wavelengths. Signal to noise ratios are presented as well as achieved spatial resolutions. The high quality of our technique is illustrated on a plasma flow radiograph obtained during a laboratory astrophysics experiment on POLARs.


1983 ◽  
Vol 101 ◽  
pp. 253-260
Author(s):  
W. H.-M. Ku ◽  
K. Long ◽  
R. Pisarski ◽  
M. Vartanian

High quality X-ray spectral and imaging observations of the Cygnus Loop have been obtained with three different instruments. The High Resolution Imager (HRI) on the Einstein Observatory was used to obtain arcsecond resolution images of select bright regions in the Cygnus Loop which permit detailed comparisons between the X-ray, optical, and radio structure of the Loop. The Imaging Proportional Counter (IPC) on the Einstein Observatory was used to obtain an arcminute resolution map of essentially the full Loop structure. Finally, an Imaging Gas Scintillation Proportional Counter (IGSPC), carried aloft by a sounding rocket last fall, obtained modest resolution, spatially resolved spectrophotometry of the Cygnus Loop. An X-ray map of the Loop in the energy of the 0 VIII line was obtained. These data combine to yield a very powerful probe of the abundance, temperature, and density distribution of material in the supernova remnant, and in the interstellar medium.


1998 ◽  
Vol 537 ◽  
Author(s):  
M. Suscavage ◽  
M. Harris ◽  
D. Bliss ◽  
P. Yip ◽  
S.-Q. Wang ◽  
...  

AbstractZinc Oxide crystals have historically been grown in hydrothermal autoclaves with a basic mineralizer; however, doubts have been raised about the quality of such crystals because they have often exhibited large x-ray rocking curve widths and low photoluminescence (PL) yield with large linewidths. Several ZnO crystals were grown hydrothermally and sliced parallel to the c-plane. This resulted in opposite surfaces (the C+ and C-) exhibiting pronounced chemical and mechanical differences. Different surface treatments were investigated and compared by PL both at room temperature and liquid helium temperatures, and by double axis X-ray rocking curve measurements. The high quality of hydrothermally-grown ZnO is substantiated by the narrow rocking curve widths and sharp PL peaks obtained. A critical factor in obtaining these results was found to be surface preparation.


1981 ◽  
Vol 248 ◽  
pp. 47 ◽  
Author(s):  
A. C. Fabian ◽  
E. M. Hu ◽  
L. L. Cowie ◽  
J. Grindlay
Keyword(s):  
X Ray ◽  
The Core ◽  

2019 ◽  
Vol 629 ◽  
pp. A144 ◽  
Author(s):  
E. Cucchetti ◽  
N. Clerc ◽  
E. Pointecouteau ◽  
P. Peille ◽  
F. Pajot

X-ray observations of the hot gas filling the intra-cluster medium (ICM) provide a wealth of information on the dynamics of clusters of galaxies. The global equilibrium of the ICM is believed to be ensured by non-thermal and thermal pressure support sources, among which gas movements and the dissipation of energy through turbulent motions. Accurate mapping of turbulence using X-ray emission lines is challenging due to the lack of spatially resolved spectroscopy. Only future instruments such as the X-ray Integral Field Unit (X-IFU) on Athena will have the spatial and spectral resolution to quantitatively investigate the ICM turbulence over a broad range of spatial scales. Powerful diagnostics for these studies are line shift and the line broadening maps, and the second-order structure function. When estimating these quantities, instruments will be limited by uncertainties of their measurements, and by the sampling variance (also known as cosmic variance) of the observation. Here, we extend the formalism started in our companion Paper I to include the effect of statistical uncertainties of measurements in the estimation of these line diagnostics, in particular for structure functions. We demonstrate that statistics contribute to the total variance through different terms, which depend on the geometry of the detector, the spatial binning and the nature of the turbulent field. These terms are particularly important when probing the small scales of the turbulence. An application of these equations is performed for the X-IFU, using synthetic turbulent velocity maps of a Coma-like cluster. Results are in excellent agreement with the formulas both for the structure function estimation (≤3%) and its variance (≤10%). The expressions derived here and in Paper I are generic, and ensure an estimation of the total errors in any X-ray measurement of turbulent structure functions. They also open the way for optimisations in the upcoming instrumentation and in observational strategies.


2004 ◽  
Vol 10 (1) ◽  
pp. 28-33 ◽  
Author(s):  
A. Howie

The key contribution of electron microscopy methods to condensed matter spectroscopy is undoubtedly spatial resolution. So far this has mainly been manifest through electron energy loss spectroscopy in the 1-eV to 10-keV energy range and has not seriously challenged the dominance of optical, X-ray, and neutron spectroscopy methods over most of the vast field at lower energies. At frequencies up to a few megahertz, corresponding to energies of a few nanoelectron volts and below, direct excitation by pulsed electron beams or electric fields has proved effective. Prospects are discussed for extending spatially resolved spectroscopy to the intermediate energy region, mainly by combining the advantages of electrons with those of photons.


2008 ◽  
Vol 1069 ◽  
Author(s):  
Hui Chen ◽  
Guan Wang ◽  
Michael Dudley ◽  
Zhou Xu ◽  
James. H. Edgar ◽  
...  

ABSTRACTA systematic study is presented of the heteroepitaxial growth of B12As2 on m-plane 15R-SiC. In contrast to previous studies of B12As2 on other substrates, including (100) Si, (110) Si, (111) Si and (0001) 6H-SiC, single crystalline and untwinned B12As2 was achieved on m-plane 15R-SiC. Observations of IBA on m-plane (1100)15R-SiC by synchrotron white beam x-ray topography (SWBXT) and high resolution transmission electron microscopy (HRTEM) confirm the good quality of the films on the 15R-SiC substrates. The growth mechanism of IBA on m-plane 15R-SiC is discussed. This work demonstrates that m-plane 15R-SiC is potentially a good substrate choice to grow high quality B12As2 epilayers.


2020 ◽  
pp. 33-39
Author(s):  
S. S. Plyasovitsa ◽  
◽  
O. A. Kravtsova ◽  
N. V. Ivanova ◽  
I. Yu. Semenov ◽  
...  

The authors carried out a mineralogical study and substantiated a concentration process developed for the lead-zinc ores of the Pavlovsk deposit. The concentration of the valuable component in each type of concentrate is determined by the amount of pyrite contained in the ore. It was established that the main loss of lead with flotation tailings is associated with oxidized phases, which are mainly found in fine material. Lead sulphides account for 30% of the entire waste tailings. Using the results of the mineralogical study, a flotation process was developed that involves a staged separation of commercial lead and zinc concentrates, as well as waste tailings. The obtained zinc concentrate has a consistently high quality of 57–58% with an 85–90% recovery. The metal concentration in the lead concentrate 1 is 45%, with the recovery being 43%. On the basis of the experimental results, the authors propose to use an X-ray radiometric separation method for coarse ore, which will help reduce the amount of incoming ore by 30% while minimizing the loss of lead and zinc.


2009 ◽  
Vol 705 (1) ◽  
pp. L62-L66 ◽  
Author(s):  
T. Tamura ◽  
Y. Maeda ◽  
K. Mitsuda ◽  
A. C. Fabian ◽  
J. S. Sanders ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document