Large-Scale Test Chamber Methodology for Urea-Formaldehyde Bonded Wood Products

Author(s):  
L. R. Newton ◽  
W. H. Anderson ◽  
H. S. Lagroon ◽  
K. A. Stephens
Holzforschung ◽  
2015 ◽  
Vol 69 (4) ◽  
pp. 457-462 ◽  
Author(s):  
Eva Höllbacher ◽  
Cornelia Rieder-Gradinger ◽  
Daniel Strateva ◽  
Ewald Srebotnik

Abstract A large-scale test set-up was designed to evaluate the volatile organic compound (VOC) emissions of building materials in a real room situation but under laboratory conditions. Two model rooms (ModR) with a volume of 30 m3 each were constructed of the wood-based building materials X-lam and OSB, respectively. Temperature and relative humidity (RH) inside the ModR were kept in a range of 21°C–25°C and 45%–55% RH. VOCs were collected at 13 different times over a period of 23 weeks, and the total VOC (TVOC) concentration was calculated from GC/MS data. Results were quantified as toluene equivalents (TE). In the X-lam-ModR, the TVOC concentration decreased by 64% over the whole measurement period from 115 to 41 μg m-3 TE. Terpenes were the most abundant substance group and accounted, on average, for 80% of the TVOC concentration. In the OSB-ModR, the TVOC concentration decreased by 72% from 443 to 124 μg m-3 TE. Aldehydes showed the highest concentrations, accounting, on average, for 52% of the TVOC, while 38% were terpenes. The results show that this type of test provides realistic data for the praxis.


2020 ◽  
Author(s):  
Rui Sun ◽  
Disa Sauter

Getting old is generally seen as unappealing, yet aging confers considerable advantages in several psychological domains (North & Fiske, 2015). In particular, older adults are better off emotionally than younger adults, with aging associated with the so-called “age advantages,” that is, more positive and less negative emotional experiences (Carstensen et al., 2011). Although the age advantages are well established, it is less clear whether they occur under conditions of prolonged stress. In a recent study, Carstensen et al (2020) demonstrated that the age advantages persist during the COVID-19 pandemic, suggesting that older adults are able to utilise cognitive and behavioural strategies to ameliorate even sustained stress. Here, we build on Carstensen and colleagues’ work with two studies. In Study 1, we provide a large-scale test of the robustness of Carstensen and colleagues’ finding that older individuals experience more positive and less negative emotions during the COVID-19 pandemic. We measured positive and negative emotions along with age information in 23,629 participants in 63 countries in April-May 2020. In Study 2, we provide a comparison of the age advantages using representative samples collected before and during the COVID-19 pandemic. We demonstrate that older people experience less negative emotion than younger people during the prolonged stress of the COVID-19 pandemic. However, the advantage of older adults was diminished during the pandemic, pointing to a likely role of older adults use of situation selection strategies (Charles, 2010).


2021 ◽  
Vol 13 (4) ◽  
pp. 544
Author(s):  
Guohao Zhang ◽  
Bing Xu ◽  
Hoi-Fung Ng ◽  
Li-Ta Hsu

Accurate localization of road agents (GNSS receivers) is the basis of intelligent transportation systems, which is still difficult to achieve for GNSS positioning in urban areas due to the signal interferences from buildings. Various collaborative positioning techniques were recently developed to improve the positioning performance by the aid from neighboring agents. However, it is still challenging to study their performances comprehensively. The GNSS measurement error behavior is complicated in urban areas and unable to be represented by naive models. On the other hand, real experiments requiring numbers of devices are difficult to conduct, especially for a large-scale test. Therefore, a GNSS realistic urban measurement simulator is developed to provide measurements for collaborative positioning studies. The proposed simulator employs a ray-tracing technique searching for all possible interferences in the urban area. Then, it categorizes them into direct, reflected, diffracted, and multipath signal to simulate the pseudorange, C/N0, and Doppler shift measurements correspondingly. The performance of the proposed simulator is validated through real experimental comparisons with different scenarios based on commercial-grade receivers. The proposed simulator is also applied with different positioning algorithms, which verifies it is sophisticated enough for the collaborative positioning studies in the urban area.


2020 ◽  
pp. 1420326X2097902
Author(s):  
Hai-Xia Xu ◽  
Yu-Tong Mu ◽  
Yin-Ping Zhang ◽  
Wen-Quan Tao

Most existing models and standards for volatile organic compounds emission assume that contaminants are uniform in the testing devices. In this study, a three-dimensional transient numerical model was proposed to simulate the mass transport process based on a full-scale test chamber with a mixing fan, and the airflow field and contaminants concentration distribution were obtained within the chamber under airtight and ventilated conditions. The model was validated by comparing the numerical results with experimental data. The numerical results show that the contaminant source position and the airflow field characteristics have significant impact on the contaminant mixing, and the fan rotation has an important role in accelerating mixing. In the initial mixing stage, the concentration distribution is obviously uneven; as the mixing progresses, it gradually reaches acceptable uniformity except for some sensitive regions, such as high concentration region at the injection point of the contaminants and low concentration region at the air inlet. To ensure test accuracy, the monitor should avoid above sensitive regions; and some special regions are recommended where contaminant concentration uniformity can be reached sooner. The ventilated chamber results indicate that the mixture of contaminants in the chamber is actually better than the results shown by conventional test method.


2021 ◽  
Author(s):  
Weixin Zhang ◽  
Lin Wu ◽  
Dujin Qiao ◽  
Jie Tian ◽  
Yan Li ◽  
...  

Safety issues limit the large-scale application of lithium-ion batteries. In this work, a new type of N-H-microcapsule fire extinguishing agent is prepared by using melamine-urea-formaldehyde resin as shell material, perfluoro(2-methyl-3-pentanone)...


2000 ◽  
Vol 122 (2) ◽  
pp. 403-411 ◽  
Author(s):  
P. W. Longest, ◽  
C. Kleinstreuer ◽  
J. S. Kinsey

Steady incompressible turbulent air flow and transient carbon monoxide transport in an empty Rochester-style human exposure chamber have been numerically simulated and compared with experimental data sets. The system consisted of an inlet duct with a continuous carbon monoxide point source, 45- and 90-degree bends, a round diffuser, a round-to-square transition, a rectangular diffuser, the test chamber, a perforated floor, and again transition pieces from the chamber to an outlet duct. Such a configuration induced highly nonuniform vortical flow patterns in the chamber test area where a pollutant concentration is required to be constant at breathing level for safe and accurate inhalation studies. Presented are validated momentum and mass transfer results for this large-scale system with the main goals of determining the development of tracer gas (CO) distributions in the chamber and analyzing the contributions to CO-mixing. Numerical simulations were conducted employing a k-ε model and the latest available RNG k-ε model for air and CO-mixing. Both models predict similar velocity fields and are in good agreement with measured steady and transient CO-concentrations. It was found that secondary flows in the inlet section and strong vortical flow in the chamber with perforated flooring contributed to effective mixing of the trace gas at breathing levels. Specifically, in the height range of 1.4 m<h<2.0 m above the chamber floor, predicted CO-concentrations rapidly reached a near constant value which agrees well with experimental results. This work can be extended to analyze trace gas mixing as well as aerosol dispersion in occupied test chambers with or without flow redirection devices installed in the upstream section. A complementary application is particle transport and deposition in clean rooms of the electronic, pharmaceutical, and health care industries. [S0098-2202(00)01702-8]


2015 ◽  
Author(s):  
Martin Kornddrfer ◽  
Boris Egloff ◽  
Stefan C. Schmukle

2011 ◽  
Vol 82 ◽  
pp. 722-727 ◽  
Author(s):  
Kristian Schellenberg ◽  
Norimitsu Kishi ◽  
Hisashi Kon-No

A system of multiple degrees of freedom composed out of three masses and three springs has been presented in 2008 for analyzing rockfall impacts on protective structures covered by a cushion layer. The model has then been used for a blind prediction of a large-scale test carried out in Sapporo, Japan, in November 2009. The test results showed substantial deviations from the blind predictions, which led to a deeper evaluation of the model input parameters showing a significant influence of the modeling properties for the cushion layer on the overall results. The cushion properties include also assumptions for the loading geometry and the definition of the parameters can be challenging. This paper introduces the test setup and the selected parameters in the proposed model for the blind prediction. After comparison with the test results, adjustments in the input parameters in order to match the test results have been evaluated. Conclusions for the application of the model as well as for further model improvements are drawn.


Sign in / Sign up

Export Citation Format

Share Document