scholarly journals A meta-analysis of accuracy and sensitivity of chest CT and RT-PCR in COVID-19 diagnosis

2020 ◽  
Vol 10 (1) ◽  
Author(s):  
Fatemeh Khatami ◽  
Mohammad Saatchi ◽  
Seyed Saeed Tamehri Zadeh ◽  
Zahra Sadat Aghamir ◽  
Alireza Namazi Shabestari ◽  
...  

AbstractNowadays there is an ongoing acute respiratory outbreak caused by the novel highly contagious coronavirus (COVID-19). The diagnostic protocol is based on quantitative reverse-transcription polymerase chain reaction (RT-PCR) and chests CT scan, with uncertain accuracy. This meta-analysis study determines the diagnostic value of an initial chest CT scan in patients with COVID-19 infection in comparison with RT-PCR. Three main databases; PubMed (MEDLINE), Scopus, and EMBASE were systematically searched for all published literature from January 1st, 2019, to the 21st May 2020 with the keywords "COVID19 virus", "2019 novel coronavirus", "Wuhan coronavirus", "2019-nCoV", "X-Ray Computed Tomography", "Polymerase Chain Reaction", "Reverse Transcriptase PCR", and "PCR Reverse Transcriptase". All relevant case-series, cross-sectional, and cohort studies were selected. Data extraction and analysis were performed using STATA v.14.0SE (College Station, TX, USA) and RevMan 5. Among 1022 articles, 60 studies were eligible for totalizing 5744 patients. The overall sensitivity, specificity, positive predictive value, and negative predictive value of chest CT scan compared to RT-PCR were 87% (95% CI 85–90%), 46% (95% CI 29–63%), 69% (95% CI 56–72%), and 89% (95% CI 82–96%), respectively. It is important to rely on the repeated RT-PCR three times to give 99% accuracy, especially in negative samples. Regarding the overall diagnostic sensitivity of 87% for chest CT, the RT-PCR testing is essential and should be repeated to escape misdiagnosis.

2020 ◽  
Author(s):  
Fatemeh Khatami ◽  
Mohammad Saatchi ◽  
Seyed Saeed Tamehri Zadeh ◽  
Zahra Sadat Aghamir ◽  
Alireza Namazi Shabestari ◽  
...  

Abstract Introduction: Nowadays there is an ongoing acute respiratory outbreak causing by the novel highly contagious coronavirus (nCoV). There are two diagnostic protocol based on chest CT scan and quantitative reverse-transcription polymerase chain reaction (RT-PCR) which their diagnostic accuracy is under the debate. We designed this meta-analysis study to determine the diagnostic value of initial chest CT scan in patients with nCoV infection in comparison with RT- PCR.Search strategy and statistical analysis: Three main databases the PubMed (MEDLINE), Scopus, and EMBASE was systematically searched for all published literatures from January 1st, 2019, to the 27th march 2020 with key grouping of “COVID19 virus”, “2019 novel coronavirus”, “Wuhan coronavirus”, “2019-nCoV”, “X-Ray Computed Tomography”, “Polymerase Chain Reaction”, “Reverse Transcriptase PCR”, and “PCR Reverse Transcriptase”. All relevant case- series, cross-sectional, and cohort studies were selected. Data extraction was done in Excel 2007 (Microsoft Corporation, Redmond, CA) and their analysis was performed using STATA v.14.0SE (College Station, TX, USA) and RevMan 5.Result: From first recruited 668 articles we end up to the final 47 studies, which comprised a total sample size of 4238 patients. In compare to RT-PCR, the overall sensitivity, specificity, positive predictive value, and negative predictive value of chest CT scan were 86% (95% CI: 83% -90%), 43 % (95% CI: 26% -60%), 67% (95% CI: 57% -78%), and 84% (95% CI: 74% -95%) respectively. However the RT-PCR should be repeated for three times in order to give the 99% accuracy especially in negative samples.Conclusion: According to the acceptable sensitivity of chest CT scan, it can be employed complement to RT-PCR to diagnosis patients who are clinically suspicious for nCoV.


2020 ◽  
Author(s):  
Mohammad Karam ◽  
Sulaiman Althuwaikh ◽  
Mohammad Alazemi ◽  
Ahmad Abul ◽  
Amrit Hayre ◽  
...  

AbstractPurposeTo compare the performance of chest computed tomography (CT) scan versus reverse transcription polymerase chain reaction (RT-PCR) in the initial diagnostic assessment of coronavirus disease 2019 (COVID-19) patients.MethodsA systematic review and meta-analysis were performed as per the Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) guidelines. A search of electronic information was conducted to identify all relevant studies comparing the diagnostic performance of chest CT scan versus RT-PCR in COVID-19 suspected cases. Sensitivity, specificity and accuracy were primary outcome measures. Secondary outcome measures included other test performance characteristics, discrepant findings between both investigations and main chest CT findings. Random effects modelling was used for the analyses.ResultsEight non-randomised retrospective studies enrolling 1910 patients were identified. Chest CT was more sensitive but less specific than RT-PCR. Accuracy was not statistically significantly different between chest CT and RT-PCR for the identification and exclusion of COVID-19 cases (Odds Ratio [OR] = 0.40, P = 0.15) in the context of hospitalised patients in a pandemic. Chest CT was shown to detect patients with false-negative RT-PCR results and true positives. Ground-glass opacities and consolidations were the most common chest CT manifestations.ConclusionsChest CT is not superior to RT-PCR for the initial detection of COVID-19 and has more false positives. It is likely to be useful in confirming COVID-19 in patients with a suspicious clinical presentation, but who have a false-negative SARS-CoV-2 RT-PCR test.Key Points‐Chest computed tomography (CT) is more sensitive but less specific in detecting and excluding coronavirus disease 2019 (COVID-19) when compared to reverse transcription polymerase chain reaction (RT-PCR).‐Accuracy of chest CT is not significantly different from RT-PCR for COVID-19 cases.‐Chest CT can detect false-negative and true-positive RT-PCR cases.


2021 ◽  
Vol 7 (2) ◽  
pp. e36-e36
Author(s):  
Kamyar Shokraee ◽  
Hossein Mahdavi ◽  
Parsa Panahi ◽  
Farnoosh Seirafianpour ◽  
Amir Mohammad Jahromizadeh ◽  
...  

Introduction: This study aims to measure the diagnostic accuracy of chest computed tomography (CT) and reverse transcription polymerase chain reaction assay (RT-PCR) in COVID-19 in a systematic review and meta-analysis. Methods: PubMed, Scopus, Embase, and Google Scholar, WHO, SSRN, and MedRxiv have been searched on March 26, 2020 for all the alternative names of the disease and virus. Risk of bias assessment was based on QUADAS-2. Data from English-language studies after January 12, 2019 were pooled to calculate necessary diagnostic values and underwent diagnostic test accuracy, random-effects, proportions, and subgroup meta-analysis. Results: Pooled from 27 included studies, the sensitivity of chest CT was calculated 96.6%, specificity 22.5%, diagnostic odds ratio (DOR) 8.2, positive likelihood ratio (PLR) 1.2 (95% CI: 1.1-1.4), and negative likelihood ratio (NLR) 0.15 (95% CI: 0.1-0.3). The sensitivity for initial RT-PCR was 79.7%, the specificity 100%, and NLR 0.18. Conclusion: Considering the results, in order to diagnose COVID-19 (coronavirus disease 2019), it is recommended to initially performing chest CT to rule out the uninfected people. In suspicious cases, we suggest RT-PCR to confirm the disease. Performing serial RT-PCR instead of the one-time test is highly recommended, to let the viral loads reach the diagnostic levels, especially in cases of high clinical suspicion.


2021 ◽  
Vol 9 (B) ◽  
pp. 865-871
Author(s):  
Rusli Muljadi ◽  
Mira Yuniarti ◽  
Ricardo Tan ◽  
Teodorus Alfons Pratama ◽  
Ignatius Bima Prasetya ◽  
...  

BACKGROUND: Reverse transcriptase-polymerase chain reaction (RT-PCR) is the primary diagnostic tool to confirm coronavirus disease 2019 (COVID-2019) due to its high specificity. However, it has relatively low sensitivity and time consuming. In contrast, chest computed tomography (CT) has high sensitivity and achieves quick results. It may, therefore, play a critical role in screening and diagnosing COVID-19. A cross-sectional study was done in 212 patients with confirmed cases and patients under surveillance for COVID-19 tested for RT-PCR and chest CT scan. Statistical analysis was performed using SPSS Version 23 (Statistical Package for the Social Sciences, IBM Corp., Armonk, NY, USA). AIM: We aim to investigate the diagnostic value of chest CT in correlation to RT-PCR in Indonesia. METHODS: A cross-sectional study was done in 212 patients with confirmed cases and patients under surveillance for COVID-19 tested for RT-PCR and chest CT scan. Statistical analysis was performed using SPSS Version 23 (Statistical Package for the Social Sciences, IBM Corp., Armonk, NY, USA). RESULTS: From a total of 212 patients, 92% of them were diagnosed as confirmed cases of COVID-19. It was found that the sensitivity of CT scan for COVID-19 patients was 72.3% (65.5% and 78.5%) with positive predictive value (PPV) of 93.9% (90.9% and 96.0%) and the sensitivity and PPV improve in symptomatic patients. Typical chest CT scan lesions were 8.0 times which were more likely (3.9–16.4; p <0.001) to be detected in symptomatic patients while patients with severe CT scan findings were 4.4 times more likely (3.0–6.5; p <0.001) to be admitted to the intensive care unit. CONCLUSION: A high PPV suggests that a chest CT scan can detect COVID-19 lesions, but the absence of the lesions would not exclude the disease’s presence.


Author(s):  
Hang Fu ◽  
Huayan Xu ◽  
Na Zhang ◽  
Hong Xu ◽  
Zhenlin Li ◽  
...  

AbstractBackgroundSince December 2019, more than 100,000 coronavirus disease 2019 (COVID-19) patients have been confirmed globally based on positive viral nucleic acids with real-time reverse transcriptase-polymerase chain reaction (RT-PCR). However, the association between clinical, laboratory and CT characteristics and RT-PCR results is still unclear. We sought to examine this association in detail, especially in recovered patients.MethodsWe analysed data from 52 confirmed patients who had been discharged with COVID-19. The clinical, laboratory, and radiological data were dynamically recorded and compared with the admission and follow-up RT-PCR results.ResultsIn this cohort, 52 admitted COVID-19 patients who had confirmed positive RT-PCR results were discharged after 2 rounds of consecutively negative RT-PCR results. Compared with admission levels, CRP levels (median 4.93 mg/L [IQR: 1.78-10.20]) decreased significantly (p<0.001). and lymphocyte counts (median 1.50×109/L [IQR: 1.11-1.88]) increased obviously after obtaining negative RT-PCR results (p<0.001). Additionally, substantially improved inflammatory exudation was observed on chest CT except for 2 progressed patients. At the two-week follow-up after discharge, 7 patients had re-positive RT-PCR results, including the abovementioned 2 progressed patients. Among the 7 patients, new GGO was demonstrated in 2 patients. There were no significant differences in CPR levels or lymphocyte counts when comparing the negative and re-positive PCT results (all p >0.05).ConclusionHeterogeneity between CT features and RT-PCR results was found in COVID-19, especially in some recovered patients with negative RT-PCR results. Our study highlights that both RT-PCR and chest CT should be considered as the key determinants for the diagnosis and management of COVID-19 patients.


2021 ◽  
Vol 12 (1) ◽  
Author(s):  
Vikram rao Bollineni ◽  
Koenraad Hans Nieboer ◽  
Seema Döring ◽  
Nico Buls ◽  
Johan de Mey

Abstract Background To evaluate the clinical value of the chest CT scan compared to the reference standard real-time polymerase chain reaction (RT-PCR) in COVID-19 patients. Methods From March 29th to April 15th of 2020, a total of 240 patients with respiratory distress underwent both a low-dose chest CT scan and RT-PCR tests. The performance of chest CT in diagnosing COVID-19 was assessed with reference to the RT-PCR result. Two board-certified radiologists (mean 24 years of experience chest CT), blinded for the RT-PCR result, reviewed all scans and decided positive or negative chest CT findings by consensus. Results Out of 240 patients, 60% (144/240) had positive RT-PCR results and 89% (213/240) had a positive chest CT scans. The sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of chest CT in suggesting COVID-19 were 100% (95% CI: 97–100%, 144/240), 28% (95% CI: 19–38%, 27/240), 68% (95% CI: 65–70%) and 100%, respectively. The diagnostic accuracy of the chest CT suggesting COVID-19 was 71% (95% CI: 65–77%). Thirty-three patients with positive chest CT scan and negative RT-PCR test at baseline underwent repeat RT-PCR assay. In this subgroup, 21.2% (7/33) cases became RT-PCR positive. Conclusion Chest CT imaging has high sensitivity and high NPV for diagnosing COVID-19 and can be considered as an alternative primary screening tool for COVID-19 in epidemic areas. In addition, a negative RT-PCR test, but positive CT findings can still be suggestive of COVID-19 infection.


2012 ◽  
Vol 3 (1) ◽  
pp. 13
Author(s):  
Aline T.A. Chagas ◽  
Michelle D. Oliveira ◽  
Jose M.S. Mezencio ◽  
Eduardo A.M. Silva ◽  
Leandro L. Oliveira ◽  
...  

The <em>Dengue virus</em> is the main arbovirus that affects man in terms of morbidity and mortality. The detection of the virus is very important for epidemiological surveillance, so here we propose to standardize and compare the immunodot blot (IDB) and multiplex reverse transcriptase-polymerase chain reaction (M-RT-PCR) techniques to detect and characterize the dengue virus (DENV) serotypes in samples of <em>Aedes aegypti</em> larvae. Thus, the IDB and M-RT-PCR techniques were standardized using macerated samples of larvae collected in nature. The use of monoclonal antibodies in IDB has not shown great results, but DENV detection through this method was possible using polyclonal antibodies. The distinction of serotypes 1, 2 and 3 was carried out by M-RT-PCR.


2020 ◽  
Vol 2 (2) ◽  
pp. 181
Author(s):  
Dwi Iva Fitriana ◽  
Endang Srimurni Kusmintarsih ◽  
Trisnowati Budi Ambarningrum

DBD dan chikungunya merupakan salah satu penyakit yang masih menjadi masalah di Indonesia. Kecamatan Cilongok merupakan salah kecamatan endemis DBD dan pernah mengalami KLB chikungunya. Deteksi virus pada nyamuk sebelum menginfeksi manusia penting sebagai peringatan dini dalam upaya pencegahan wabah di daerah endemis. Tujuan penelitian ini adalah mengetahui infeksi virus Dengue dan Chikungunya pada nyamuk Aedes spp. yang ditangkap. Penelitian ini dilakukan di empat desa di Kecamatan Cilongok yang meliputi Desa Cilongok, Pernasidi, Kalisari, dan Jatisaba, pengambilan sampel dilakukan secara purposive. Deteksi virus Dengue dan Chikungunya pada nyamuk dilakukan menggunakan metode Reverse-Transcriptase Polymerase Chain Reaction (RT-PCR). Hasil positifitas virus dianalisis secara deskriptif untuk menggambarkan potensi transmisi virus. Hasil penelitian menunjukkan bahwa nyamuk Aedes spp. yang tertangkap tidak mengandung virus Dengue dan Chikungunya.  


Sign in / Sign up

Export Citation Format

Share Document