scholarly journals Coronal and axial alignment relationship in Caucasian patients with osteoarthritis of the knee

2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Vicente J. León-Muñoz ◽  
Silvio Manca ◽  
Mirian López-López ◽  
Francisco Martínez-Martínez ◽  
Fernando Santonja-Medina

AbstractIndividualized pre-operative assessment of the patterns of the lower extremity anatomy and deformities in patients undergoing total knee arthroplasty seems essential for a successful surgery. In the present study, we investigated the relationship among the coronal alignment and the rotational profile of the lower extremities in the Caucasian population with end-stage knee osteoarthritis. We conducted a prospective study of 385 knees that underwent a pre-operative three-dimensional computed tomography-based model. The lower extremity alignment was determined (mechanical tibiofemoral or hip-knee-ankle angle, supplementary angle of the femoral lateral distal angle, and proximal medial tibial angle). For each case, the femoral distal rotation (condylar twist angle), the femoral proximal version, and the tibial torsion were determined. As the coronal alignment changed from varus to valgus, the femoral external rotation increased (r = 0.217; p < 0.0005). As the coronal alignment changed from varus to valgus, the external tibial torsion increased (r = 0.248; p < 0.0005). No correlation was found between the global coronal alignment and the femoral version. The present study demonstrates a linear relationship between the coronal alignment and the rotational geometry of the distal femur. This correlation also occurs with the tibial torsion. Perhaps outcomes of total knee arthroplasty surgery might be improved by addressing these deformities as well.

2021 ◽  
pp. 46-48
Author(s):  
Pooyan Jalalpour ◽  
Mohammadreza Minator Sajadi ◽  
Seyed Amirali Matini ◽  
Kamyar Makvandi

Background and Aims: Achieving proper axial rotational alignment of the femoral component for varus knees is a critical step in total knee arthroplasty (TKA). Trans epicondylar axis (TEA) is the most reliable reference for alignment of femoral component. Yet, nding the exact location is sometimes difcult and time consuming. The aim of this study was to determine the correlation between the TEA and posterior condylar line reference (PCL) in varus knees. Besides, the other aim of this study was to nd the relationship between lateral distal femoral angle (LDFA) and femoral component external rotation (ER) measured intraoperatively. Material and Methods: This retrospective study was conducted on patients who were candidates for total knee arthroplasty from May 2016 to December 2019. LDFA, VA were calculated based on hip-to-ankle (HTA) radiographs before the surgery. All patients underwent TKA through an anterior midline incision. ER was calculated by determining TEA intraoperatively. All data were entered into SPSS software for data analysis. Results: One hundred and four patients were included in the nal analysis. Nineteen patients (18.3%) were male and 85 out of 104 (81.7%) were female. (P value = 0.001). No signicant relationship between the amount of ER measured during surgery and the amount of varus angle in varus knees was observed. Furthermore, there were no correlations between ER and LDFA in varus knees. Conclusion: Adjusting femoral component in 3 degrees external rotation relative to posterior condylar line reference achieves proper rotational alignment of the femoral component in the axial plane in varus knees. Also, the lateral distal femoral angle measured preoperatively from knee radiographs is not a predictor of ER in varus knees


Author(s):  
Mehmet Emin Simsek ◽  
Mustafa Akkaya ◽  
Safa Gursoy ◽  
Özgür Kaya ◽  
Murat Bozkurt

AbstractThis study aimed to investigate whether overhang or underhang around the tibial component that occurs during the placement of tibial baseplates was affected by different slope angles of the tibial plateau and determine the changes in the lateral and medial plateau diameters while changing the slope angle in total knee arthroplasty. Three-dimensional tibia models were reconstructed using the computed tomography scans of 120 tibial dry bones. Tibial plateau slope cuts were performed with 9, 7, 5, 3, and 0 degrees of slope angles 2-mm below the subchondral bone in the deepest point of the medial plateau. Total, lateral, and medial tibial plateau areas and overhang/underhang rates were measured at each cut level. Digital implantations of the asymmetric and symmetric tibial baseplates were made on the tibial plateau with each slope angles. Following the implantations, the slope angle that prevents overhang or underhang at the bone border and the slope angle that has more surface area was identified. A significant increase was noted in the total tibial surface area, lateral plateau surface area, and lateral anteroposterior distance, whereas the slope cut angles were changed from 9 to 0 degrees in both gender groups. It was found that the amount of posteromedial underhang and posterolateral overhang increased in both the asymmetric and symmetric tibial baseplates when the slope angle was changed from 0 to 9 degrees. Although the mediolateral diameter did not change after the proximal tibia cuts at different slope angles, the surface area and anteroposterior diameter of the lateral plateau could change, leading to increased lateral plateau area. Although prosthesis designs are highly compatible with the tibial surface area, it should be noted that the component overhangs, especially beyond the posterolateral edge, it can be prevented by changing the slope cut angle in males and females.


2020 ◽  
Vol 79 (Suppl 1) ◽  
pp. 807.3-807
Author(s):  
I. Moriyama

Background:No widely accepted view or criteria currently exist concerning whether or not patellar replacement (resurfacing) should accompany total knee arthroplasty for osteoarthritis of the knee.1)2)3)Objectives:We recently devised our own criteria for application of patellar replacement and performed selective patellar replacement in accordance with this set of criteria. The clinical outcome was analyzed.Methods:The study involved 1150 knees on which total knee arthroplasty was performed between 2005 and 2019 because of osteoarthritis of the knee. The mean age at operation was 73, and the mean postoperative follow-up period was 91 months. Our criteria for application of patellar replacement are given below. Criterion A pertains to evaluation of preoperative clinical symptoms related to the patellofemoral joint: (a) interview regarding presence/absence of pain around the patella, (b) cracking or pain heard or felt when standing up from a low chair, (c) pain when going upstairs/downstairs. Because it is difficult for individual patients to identify the origin of pain (patellofemoral joint or femorotibial joint), the examiner advised each patient about the location of the patellofemoral joint when checking for these symptoms. Criterion B pertains to intense narrowing or disappearance of the patellofemoral joint space on preoperative X-ray of the knee. Criterion C pertains to the intraoperatively assessed extent of patellar cartilage degeneration corresponding to class 4 of the Outerbridge classification. Patellar replacement was applied to cases satisfying at least one of these sets of criteria (A-a,-b,-c, B and C). Postoperatively, pain of the patellofemoral joint was evaluated again at the time of the last observation, using Criterion A-a,-b,-c.Results:Patellar replacement was applied to 110 knees in accordance with the criteria mentioned above. There were 82 knees satisfying at least one of the Criterion sets A-a,-b,-c, 39 knees satisfying Criterion B and 70 knees satisfying Criterion C. (Some knees satisfied 2 or 3 of Criteria A, B and C).When the pain originating from patellofemoral joint (Criterion A) was clinically assessed at the time of last observation, pain was not seen in any knee of the replacement group and the non-replacement group.Conclusion:Whether or not patellar replacement is needed should be determined on the basis of the symptoms or findings related to the patellofemoral joint, and we see no necessity of patellar replacement in cases free of such symptoms/findings. When surgery was performed in accordance with the criteria on patellar replacement as devised by us, the clinical outcome of the operated patellofemoral joint was favorable, although the follow-up period was not long. Although further follow-up is needed, the results obtained indicate that selective patellar replacement yields favorable outcome if applied to cases judged indicated with appropriate criteria.References:[1]The Effect of Surgeon Preference for Selective Patellar Resurfacing on Revision Risk in Total Knee Replacement: An Instrumental Variable Analysis of 136,116 Procedures from the Australian Orthopaedic Association National Joint Replacement Registry.Vertullo CJ, Graves SE, Cuthbert AR, Lewis PL J Bone Joint Surg Am. 2019 Jul 17;101(14):1261-1270[2]Resurfaced versus Non-Resurfaced Patella in Total Knee Arthroplasty.Allen W1, Eichinger J, Friedman R. Indian J Orthop. 2018 Jul-Aug;52(4):393-398.[3]Is Selectively Not Resurfacing the Patella an Acceptable Practice in Primary Total Knee Arthroplasty?Maradit-Kremers H, Haque OJ, Kremers WK, Berry DJ, Lewallen DG, Trousdale RT, Sierra RJ. J Arthroplasty. 2017 Apr;32(4):1143-1147.Disclosure of Interests:None declared


Author(s):  
Hideki Mizu-uchi ◽  
Hidehiko Kido ◽  
Tomonao Chikama ◽  
Kenta Kamo ◽  
Satoshi Kido ◽  
...  

AbstractThe optimal placement within 3 degrees in coronal alignment was reportedly achieved in only 60 to 80% of patients when using an extramedullary alignment guide for the tibial side in total knee arthroplasty (TKA). This probably occurs because the extramedullary alignment guide is easily affected by the position of the ankle joint which is difficult to define by tibial torsion. Rotational direction of distal end of the extramedullary guide should be aligned to the anteroposterior (AP) axis of the proximal tibia to acquire optimal coronal alignment in the computer simulation studies; however, its efficacy has not been proven in a clinical setting. The distal end of the guide can be overly displaced from the ideal position when using a conventional guide system despite the alignment of the AP axis to the proximal tibia. This study investigated the effect of displacement of the distal end of extramedullary guide relative to the tibial coronal alignment while adjusting the rotational alignment of the distal end to the AP axis of the proximal tibia in TKA. A total of 50 TKAs performed in 50 varus osteoarthritic knees using an image-free navigation system were included in this study. The rotational alignment of the proximal side of the guide was adjusted to the AP axis of the proximal tibia. The position of the distal end of the guide was aligned to the center of the ankle joint as viewed from the proximal AP axis (ideal position) and as determined by the navigation system. The tibial intraoperative coronal alignments were recorded as the distal end was moved from the ideal position at 3-mm intervals. The intraoperative alignments were 0.5, 0.9, and 1.4 degrees in valgus alignment with 3-, 6-, and 9-mm medial displacements, respectively. The intraoperative alignments were 0.7, 1.2, and 1.7 degrees in varus alignment with 3-, 6-, and 9-mm lateral displacements, respectively. In conclusion, the acceptable tibial coronal alignment (within 2 degrees from the optimal alignment) can be achieved, although some displacement of the distal end from the ideal position can occur after the rotational alignment of the distal end of the guide is adjusted to the AP axis of the proximal tibia.


Author(s):  
Pablo Besa ◽  
Rafael Vega ◽  
Gerardo Ledermann ◽  
Claudio Calvo ◽  
Manuela Angulo ◽  
...  

AbstractThis study aimed to determine the tibial cut (TC) accuracy using extensor hallucis longus (EHL) tendon as an anatomical landmark to position the total knee arthroplasty (TKA) extramedullary tibial guide (EMTG), and its impact on the TKA mechanical alignment (MA). We retrospectively studied 96 TKA, performed by a single surgeon, using a femoral tailored intramedullary guide technique. Seventeen were prior to the use of the EHL and 79 used the EHL tendon to position the EMTG. We analyzed preoperative and postoperative standing total lower extremity radiographs to determine the tibial component angle (TCA) and the correction in MA, comparing pre-EHL use and post-EHL technique incorporation. Mean TCA was 88.89 degrees and postoperative MA was neutral in 81% of patients. Pre- and postoperative MAs were not correlated. As a conclusion of this study, using the EHL provides a safe and easy way to determine the position of EMTG.


2020 ◽  
Vol 79 (Suppl 1) ◽  
pp. 1932.1-1933
Author(s):  
M. Eymir ◽  
E. Yuksel ◽  
B. Unver ◽  
K. Sevik ◽  
V. Karatosun

Background:Patients with TKA show impairments in standing balance up to 1 year after surgery. The impaired standing balance in TKA patients was found to be associated with falls risk and decreased functional level. Assessing of standing balance with objective and reliable assessments tools would therefore be extremely useful for determining accurate exercise program, and risks of falling, especially during the rehabilitative period when ambulation is at its most unsteady (1, 2). The stepping maneuver requires adequate strength and motor control to stabilize the body over the stance limb while the other leg is stepping, therefore the Step Test (ST) provides significant information for dynamic standing balance and lower limb motor control (3). The reliability of ST is reported in patient groups such as stroke, however, there is not any study that investigates the reliability of ST in patients with TKA in the current literature.Objectives:The purposes of this study were to determine the test-retest reliability and the minimal detectable change (MDC) of the ST in patients with TKA.Methods:40 patients with TKA due to knee osteoarthritis, operated by the same surgeon, were included in this study. Patients performed trials for ST twice on the same day. Between the first and second trials, patients waited for an hour on sitting position to prevent fatigue. The ST assesses an individual’s ability to place one foot onto a 7.5-cm-high step and then back down to the floor repeatedly as fast as possible for 15 seconds. The score is the number of steps completed in the 15-second period for each lower extremity. Scores for each lower extremity were recorded separately. Prior to the testing, the ST was demonstrated by the tester and all participants were allowed to a practice trial.Results:The ST showed an excellent test-retest reliability (ICC2,1=0.95) in this study. Standard error of measurement (SEM) and MDC95for ST were 0.37 and 1.02, respectively.Conclusion:This study found that the ST has an excellent test–retest reliability in patients with TKA. It is an effective and reliable tool for measuring dynamic standing balance and participant falls. As a performance-based clinical test, the ST is easy to score, can be applied in a short time as part of the routine medical examination. Therefore, inclusion of ST into a more comprehensive battery of performance-based measures of standing balance and lower limb motor control function in subjects with TKA should be considered.References:[1]Si, H. B., Zeng, Y., Zhong, J., et al. (2017). The effect of primary total knee arthroplasty on the incidence of falls and balance-related functions in patients with osteoarthritis. Scientific reports, 7(1), 1-9.[2]Moutzouri, M., Gleeson, N., Billis, E., et al. (2017). The effect of total knee arthroplasty on patients’ balance and incidence of falls: a systematic review. Knee Surgery, Sports Traumatology, Arthroscopy, 25(11), 3439-3451.[3]Hill, K. D., Bernhardt, J., McGann, A. M., et al. (1996). A new test of dynamic standing balance for stroke patients: reliability, validity and comparison with healthy elderly. Physiotherapy Canada, 48(4), 257-262.Disclosure of Interests:None declared


2019 ◽  
Vol 20 (1) ◽  
Author(s):  
Ye-Ran Li ◽  
Yu-Hang Gao ◽  
Chen Yang ◽  
Lu Ding ◽  
Xuebo Zhang ◽  
...  

Abstract Background Despite potential for improving patient outcomes, studies using three-dimensional measurements to quantify proximal tibial sclerotic bone and its effects on prosthesis stability after total knee arthroplasty (TKA) are lacking. Therefore, this study aimed to determine: (1) the distribution range of tibial sclerotic bone in patients with severe genu varum using three-dimensional measurements, (2) the effect of the proximal tibial sclerotic bone thickness on prosthesis stability according to finite-element modelling of TKA with kinematic alignment (KA), mechanical alignment (MA), and 3° valgus alignment, and (3) the effect of short extension stem augment utilization on prosthesis stability. Methods The sclerotic bone in the medial tibial plateau of 116 patients with severe genu varum was measured and classified according to its position and thickness. Based on these cases, finite-element models were established to simulate 3 different tibial cut alignments with 4 different thicknesses of the sclerotic bone to measure the stress distribution of the tibia and tibial prosthesis, the relative micromotion beneath the stem, and the influence of the short extension stem on stability. Results The distribution range of proximal tibial sclerotic bone was at the anteromedial tibial plateau. The models were divided into four types according to the thickness of the sclerotic bone: 15 mm, 10 mm, 5 mm, and 0 mm. The relative micromotion under maximum stress was smallest after MA with no sclerotic bone (3241 μm) and largest after KA with 15 mm sclerotic bone (4467 μm). Relative micromotion was largest with KA and smallest with MA in sclerotic models with the same thickness. Relative micromotion increased as thickness of the sclerotic bone increased with KA and MA (R = 0.937, P = 0.03 and R = 0.756, P = 0.07, respectively). Relative micromotion decreased with short extension stem augment in the KA model when there was proximal tibial sclerotic bone. Conclusions The influence of proximal tibial sclerotic bone on prosthesis’s stability is significant, especially with KA tibial cut. Tibial component’s short extension stem augment can improve stability.


Sign in / Sign up

Export Citation Format

Share Document