scholarly journals Patient-specific computational simulation of coronary artery bifurcation stenting

2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Shijia Zhao ◽  
Wei Wu ◽  
Saurabhi Samant ◽  
Behram Khan ◽  
Ghassan S. Kassab ◽  
...  

AbstractPatient-specific and lesion-specific computational simulation of bifurcation stenting is an attractive approach to achieve individualized pre-procedural planning that could improve outcomes. The objectives of this work were to describe and validate a novel platform for fully computational patient-specific coronary bifurcation stenting. Our computational stent simulation platform was trained using n = 4 patient-specific bench bifurcation models (n = 17 simulations), and n = 5 clinical bifurcation cases (training group, n = 23 simulations). The platform was blindly tested in n = 5 clinical bifurcation cases (testing group, n = 29 simulations). A variety of stent platforms and stent techniques with 1- or 2-stents was used. Post-stenting imaging with micro-computed tomography (μCT) for bench group and optical coherence tomography (OCT) for clinical groups were used as reference for the training and testing of computational coronary bifurcation stenting. There was a very high agreement for mean lumen diameter (MLD) between stent simulations and post-stenting μCT in bench cases yielding an overall bias of 0.03 (− 0.28 to 0.34) mm. Similarly, there was a high agreement for MLD between stent simulation and OCT in clinical training group [bias 0.08 (− 0.24 to 0.41) mm], and clinical testing group [bias 0.08 (− 0.29 to 0.46) mm]. Quantitatively and qualitatively stent size and shape in computational stenting was in high agreement with clinical cases, yielding an overall bias of < 0.15 mm. Patient-specific computational stenting of coronary bifurcations is a feasible and accurate approach. Future clinical studies are warranted to investigate the ability of computational stenting simulations to guide decision-making in the cardiac catheterization laboratory and improve clinical outcomes.

Author(s):  
Thomas F. Valenzuela ◽  
Francesco Burzotta ◽  
Tinen L. Iles ◽  
Jens F. Lassen ◽  
Paul A. Iaizzo

AbstractStent implantation in bifurcated coronary lesions is technically challenging so that procedural refinements are continuously investigated. Novel procedure modeling and intracoronary imaging techniques may offer critical insights on stent deformations and stent-wall interactions during bifurcation stenting procedures. Thus, we assessed coronary bifurcation stenting techniques using multimodal imaging and 3D modeling in reanimated swine hearts. Harvested swine hearts were reanimated using Visible Heart® methodologies and (under standard fluoroscopic guidance) used to test 1-stent (provisional and inverted provisional) and 2-stent (culotte, TAP and DK-crush) techniques on bifurcations within various coronary vessels using commercially available devices. Intracoronary angioscopy and frequency-domain optical-coherence-tomography (OCT) were obtained during the procedures. 3D OCT reconstruction and micro-computed tomography 3D modeling (post heart fixations) were used to assess stent deformations and stent-wall interactions. We conducted multiple stenting procedures and collected unique endoscopic and OCT images (and subsequent computational models from micro-CT) to assess stent deformations and device/wall interactions during different steps of bifurcation stenting procedures. Endoscopy, micro-CT and virtual reality processing documented that different 1- and 2-stent techniques, practiced according to experts’ recommended steps, achieve optimal post-intervention stent conformation. As compared with intra-procedural endoscopy, software-generated 3D OCT images accurately depicted stent deformations during 1-stent techniques. On the opposite, during more complex 2-stent techniques, some defects were appreciated at 3D OCT reconstruction despite optimal 2D OCT images. This study provided unique insights regarding both stent deformations occurring in the course of bifurcation stenting and the efficacy of OCT to visualize them.


2018 ◽  
Vol 8 (9) ◽  
pp. 1510 ◽  
Author(s):  
Susanna Migliori ◽  
Rajiv Rampat ◽  
Marco Bologna ◽  
Eros Montin ◽  
Francesco Burzotta ◽  
...  

We present an application of a validated reconstruction methodology for the comparison between patient-specific hemodynamics and neo-intimal thickening at nine months from the intervention. (1) Background: Coronary bifurcation stenting alters the vessel geometry, influencing the local hemodynamics. The evaluation of wall shear stress (WSS) relies on the application of computational fluid dynamics to model its distribution along the coronary tree. The endothelium actively responds to WSS, which triggers eventual cell proliferation to cover the stent struts. (2) Methods: Baseline optical coherence tomography and angiographic data were combined to reconstruct a patient-specific coronary bifurcation with an implanted bioresorbable scaffold and to simulate the hemodynamics. Results were linked with the neo-intimal thickening after nine months from the intervention. (3) Results: Blood velocity patterns were disrupted at the bifurcation due to the presence of the stent. It was observed that 55.6% of the scaffolded lumen surface was exposed to values of time-averaged WSS lower than 0.4 Pa. Follow-up images showed a luminal narrowing of 19% in the main branch. There was also a complete coverage in 99% of struts. (4) Conclusions: This approach provided valuable complementary information that might improve the clinical outcomes in this subset of coronary diseases.


2015 ◽  
Vol 11 (V) ◽  
pp. V35-V39 ◽  
Author(s):  
Peter Mortier ◽  
Jolanda J. Wentzel ◽  
Gianluca De Santis ◽  
Claudio Chiastra ◽  
Francesco Migliavacca ◽  
...  

2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Angad Malhotra ◽  
Matthias Walle ◽  
Graeme R. Paul ◽  
Gisela A. Kuhn ◽  
Ralph Müller

AbstractMethods to repair bone defects arising from trauma, resection, or disease, continue to be sought after. Cyclic mechanical loading is well established to influence bone (re)modelling activity, in which bone formation and resorption are correlated to micro-scale strain. Based on this, the application of mechanical stimulation across a bone defect could improve healing. However, if ignoring the mechanical integrity of defected bone, loading regimes have a high potential to either cause damage or be ineffective. This study explores real-time finite element (rtFE) methods that use three-dimensional structural analyses from micro-computed tomography images to estimate effective peak cyclic loads in a subject-specific and time-dependent manner. It demonstrates the concept in a cyclically loaded mouse caudal vertebral bone defect model. Using rtFE analysis combined with adaptive mechanical loading, mouse bone healing was significantly improved over non-loaded controls, with no incidence of vertebral fractures. Such rtFE-driven adaptive loading regimes demonstrated here could be relevant to clinical bone defect healing scenarios, where mechanical loading can become patient-specific and more efficacious. This is achieved by accounting for initial bone defect conditions and spatio-temporal healing, both being factors that are always unique to the patient.


Author(s):  
Mohammed Osman ◽  
Yasir Abdul Ghaffar ◽  
Khansa Osman ◽  
Babikir Kheiri ◽  
Mohamed M. G. Mohamed ◽  
...  

2016 ◽  
Vol 8 (1) ◽  
pp. 11-12
Author(s):  
Julien Adjedj ◽  
Gabor Toth ◽  
Mariano Pellicano ◽  
Angela Ferrara ◽  
Vincent Flore ◽  
...  

Author(s):  
Paul N. Watton ◽  
Marc Homer ◽  
Justin Penrose ◽  
Harry Thompson ◽  
Haoyu Chen ◽  
...  

Intracranial aneurysms appear as sac-like outpouchings of the cerebral vasculature wall; inflated by the pressure of the blood that fills them. They are relatively common and affect up to 5% of the adult population. Fortunately, most remain asymptomatic. However, there is a small but inherent risk of rupture: 0.1% to 1% of detected aneurysms rupture every year. If rupture does occur there is a 30% to 50% chance of fatality. Consequently, if an aneurysm is detected, clinical intervention may be deemed appropriate. Therapy is currently aimed at pre-rupture detection and preventative treatment. However, interventional procedures are not without risk to the patient. The improvement and optimization of interventional techniques is an important concern for patient welfare and is necessary for rationalisation of healthcare priorities. Hence there is a need to develop methodologies to assist in identifying those ICAs most at risk of rupture. We focus on the mathematical modelling and computational simulation of ICA evolution. Models must take into consideration: (i) the biomechanics of the arterial wall; (ii) the biology of the arterial wall and (iii) the complex interplay between (i) and (ii), i.e. the mechanobiology of the arterial wall. The ultimate ambition of such models is to aid clinical diagnosis on a patient-specific basis. However, due to the significant biological complexity coupled with limited histological information such models are still in their relative infancy. Current research focuses on simulating the evolution of an ICA with an aim to yield insight into the growth and remodelling (G&R) processes that give rise to inception, enlargement, stabilisation and rupture. We present a novel Fluid-Structure-Growth computational framework for modelling aneurysm evolution.


2009 ◽  
Vol 2 (1) ◽  
pp. 27-34 ◽  
Author(s):  
Andrejs Erglis ◽  
Indulis Kumsars ◽  
Matti Niemelä ◽  
Kari Kervinen ◽  
Michael Maeng ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document