Detection of cyanide by a novel probe with a V-shaped structure based on aggregation of the probe adduct

RSC Advances ◽  
2016 ◽  
Vol 6 (89) ◽  
pp. 85787-85794 ◽  
Author(s):  
Xiao-Lin Lu ◽  
Min Xia

A novel V-shaped probe is reported with extremely rapid response, high selectivity and very low detection limit to cyanide anions in aqueous solution based on the intensely emissive aggregates of the probe adduct.

2018 ◽  
Vol 42 (24) ◽  
pp. 19450-19457 ◽  
Author(s):  
Nannan Jian ◽  
Kaiwen Lin ◽  
Bin Guo ◽  
Ge Zhang ◽  
Ximei Liu ◽  
...  

Electrosynthesized oligo(1-pyrenesulfonic acid) displays high selectivity, low detection limit and outstanding reversibility in the detection of Fe3+ in aqueous solution.


2014 ◽  
Vol 50 (19) ◽  
pp. 2498-2501 ◽  
Author(s):  
Qiaoling Liu ◽  
Lixia Feng ◽  
Caixia Yuan ◽  
Lin Zhang ◽  
Shaomin Shuang ◽  
...  

A bifluorophoric probe displays high selectivity for Cd2+ and a low detection limit of 20 nM Cd2+ in aqueous solution.


Author(s):  
Ziyu Wang ◽  
Meiyun Xu ◽  
Nan Zhang ◽  
Jian-Bin Pan ◽  
Xinqi Wu ◽  
...  

A mechanism of co-reactive group poisoning (CGP) was discovered for designing efficient I2 vapor sensors for early warning of a nuclear emergency, which give an ultra-low detection limit of 0.13 ppt as well as high selectivity.


2013 ◽  
Vol 295-298 ◽  
pp. 475-478 ◽  
Author(s):  
Zhi Xiang Han ◽  
Ming Hui Du ◽  
Guo Xi Liang ◽  
Xiang Yang Wu

Rhodamine B thiohydrazide (RBS) was firstly employed as turn-on fluorescent probe for hypochlorite in aqueous solution and living cells. It exhibits a stable response to hypochlorite from 1.0×10-6to 1.0×10-5M with a detection limit of 3.3×10-7M. The response of this probe to hypochlorite is fast and highly selective compared with other reactive oxygen species (such as.OH,1O2, H2O2) and other common anions (such as X-, ClO2-, ClO4-, NO3-, NO2-, OH-, Ac-, CO32-, SO42-).


2016 ◽  
Vol 40 (3) ◽  
pp. 1930-1934 ◽  
Author(s):  
M. Raju ◽  
Tapasya J. Patel ◽  
Ratish R. Nair ◽  
Pabitra B. Chatterjee

Synopsis: A well-known tryptophan metabolite, xanthurenic acid, a natural non-fluorescent intermediate siderophore, showed a very selective turn-on response to K+ over other competing metal ions and the detection limit of this natural ionophore was found to be 53 nM at physiological pH.


RSC Advances ◽  
2016 ◽  
Vol 6 (90) ◽  
pp. 87110-87114 ◽  
Author(s):  
Dongjian Zhu ◽  
Yanghe Luo ◽  
Xiaowei Yan ◽  
Wei Xie ◽  
Wen Cai ◽  
...  

FP can detect Cu2+ in complete aqueous solution with a rapid response time, high sensitivity, and high selectivity.


RSC Advances ◽  
2014 ◽  
Vol 4 (81) ◽  
pp. 43110-43113 ◽  
Author(s):  
Jiayu Zha ◽  
Boqiao Fu ◽  
Caiqin Qin ◽  
Lintao Zeng ◽  
Xichao Hu

A novel fluorescent probe displayed a colorimetric response to ClO− with high selectivity, fast response and a low detection limit (0.08 μM).


The Analyst ◽  
2015 ◽  
Vol 140 (9) ◽  
pp. 3285-3289 ◽  
Author(s):  
Fang Liu ◽  
Changqin Ding ◽  
Ming Jin ◽  
Yang Tian

A two-photon fluorescent sensor ATD was developed for Hg2+ determination with high selectivity and low detection limit, in which two-photon fluorophore TD was designed and synthesized with a specific recognition molecule for Hg2+ – PT.


2019 ◽  
Vol 43 (14) ◽  
pp. 5525-5530 ◽  
Author(s):  
Gurjaspreet Singh ◽  
Akshpreet Singh ◽  
Pinky Satija ◽  
Geetika Sharma ◽  
Shilpy Shilpy ◽  
...  

This study involves the synthesis of a silatrane-based receptor using Knoevenagel condensation and click chemistry approach for the recognition of silver ions in aqueous solution.


Sign in / Sign up

Export Citation Format

Share Document