Colorimetric and Fluorescent Probe for Hypochlorite with High Selectivity

2013 ◽  
Vol 295-298 ◽  
pp. 475-478 ◽  
Author(s):  
Zhi Xiang Han ◽  
Ming Hui Du ◽  
Guo Xi Liang ◽  
Xiang Yang Wu

Rhodamine B thiohydrazide (RBS) was firstly employed as turn-on fluorescent probe for hypochlorite in aqueous solution and living cells. It exhibits a stable response to hypochlorite from 1.0×10-6to 1.0×10-5M with a detection limit of 3.3×10-7M. The response of this probe to hypochlorite is fast and highly selective compared with other reactive oxygen species (such as.OH,1O2, H2O2) and other common anions (such as X-, ClO2-, ClO4-, NO3-, NO2-, OH-, Ac-, CO32-, SO42-).

2018 ◽  
Vol 2018 ◽  
pp. 1-8 ◽  
Author(s):  
Xiaohua Ma ◽  
Guoguang Wu ◽  
Yuehua Zhao ◽  
Zibo Yuan ◽  
Yu Zhang ◽  
...  

We reported here a turn-on fluorescent probe (1) for the detection of cysteine (Cys) by incorporating the recognition unit of 2,4-dinitrobenzenesulfonyl ester (DNBS) to a coumarin derivative. The structure of the obtained probe was confirmed by NMR and HRMS techniques. The probe shows a remarkable fluorescence off-on response (∼52-fold) by the reaction with Cys in 100% aqueous buffer. The sensing mechanism was verified by the HPLC test. Probe 1 also displays high selectivity towards Cys. The detection limit was calculated to be 23 nM. Moreover, cellular experiments demonstrated that the probe is highly biocompatible and can be used for monitoring intracellular Cys.


The Analyst ◽  
2021 ◽  
Author(s):  
Fangyun Xin ◽  
Jiwei Zhao ◽  
Wei Shu ◽  
Xiaoling Zhang ◽  
Xixian Luo ◽  
...  

Peroxynitrite (ONOO‒), a highly reactive oxygen species (ROS), is implicated with many physiological and pathological processes including cancer, neurodegenerative diseases and inflammation. In this regard, developing effective tools for highly...


2020 ◽  
Vol 44 (5-6) ◽  
pp. 349-353
Author(s):  
Xue-Tao Pan ◽  
Qiao Li ◽  
Yuan-Yuan Xu ◽  
Sheng-Li Hu

A new 3-hydroxyphthalimide-based turn-on fluorescent probe is designed and synthesized. This probe can be used to determine the presence of Hg2+ ions by fluorescence spectroscope with high selectivity over other metal ions in aqueous solution. The analytical detection limit for Hg2+ is as low as 6.5 × 10−7 M. The recognition mechanism is attributed to Hg2+-promoted carbonothioate group cleavage and a subsequent excited-state intramolecular proton transfer mechanisms.


RSC Advances ◽  
2016 ◽  
Vol 6 (57) ◽  
pp. 52004-52008 ◽  
Author(s):  
Xiaofeng Yang ◽  
Yan Zhang ◽  
Yexin Li ◽  
Xiaolei Liu ◽  
Jiaxin Mao ◽  
...  

A diketopyrrolopyrrole-based fluorescent probeDPP-HBTbearing a benzothiazole hydrazone motif exhibited an obvious fluorescent turn-on response toward Pb2+ions with a low detection limit of 2.3 × 10−10M in aqueous solution.


2014 ◽  
Vol 50 (19) ◽  
pp. 2498-2501 ◽  
Author(s):  
Qiaoling Liu ◽  
Lixia Feng ◽  
Caixia Yuan ◽  
Lin Zhang ◽  
Shaomin Shuang ◽  
...  

A bifluorophoric probe displays high selectivity for Cd2+ and a low detection limit of 20 nM Cd2+ in aqueous solution.


RSC Advances ◽  
2021 ◽  
Vol 11 (39) ◽  
pp. 24032-24037
Author(s):  
Rongrong Zhou ◽  
Qiyao Peng ◽  
Dan Wan ◽  
Chao Yu ◽  
Yuan Zhang ◽  
...  

Hydrogen peroxide (H2O2), an important reactive oxygen species (ROS) with unique destructive oxidation properties, can be produced in lysosomes to fight off pathogens.


Sign in / Sign up

Export Citation Format

Share Document