Development and validation of a robust analytical method to quantify both etoposide and prodigiosin in polymeric nanoparticles by reverse-phase high-performance liquid chromatography

2018 ◽  
Vol 10 (19) ◽  
pp. 2272-2280 ◽  
Author(s):  
M. M. Agwa ◽  
F. M. Elessawy ◽  
A. Hussein ◽  
M. A. El Demellawy ◽  
A. O. Elzoghby ◽  
...  

Preparation of the ETP-PRO loaded B-CN nanocarrier (1) and analysis of the % of ETP and PRO released (2) using the validated HPLC method (3).

2020 ◽  
Vol 11 (02) ◽  
pp. 296-302
Author(s):  
Aseem Kumar ◽  
Anil Kumar Sharma ◽  
Rohit Dutt

The present work demonstrates a simple, rapid, precise, specific, and sensitive reverse-phase high-performance liquid chromatography (RP-HPLC) method for analyzing glimepiride in pure and tablet forms. The present method was developed using a C18 column 150 × 4.6 mm, with 5 μm, and packing L1 maintained at a temperature of 30°C. The mobile phase was prepared by dissolving 0.5 gram of monobasic sodium phosphate in 500 mL of distilled water, pH of the solution adjusted to 2.1 to 2.7 with 10% phosphoric acid, and added 500 mL of acetonitrile. The mobile phase was pumped in the highperformance liquid chromatography (HPLC) system at a flow rate of 1 mL/min, and separation was carried out at 228 nm, using an ultraviolet (UV) detector. The chromatographic separation was achieved with peak retention time (RT) at about 9.30 minutes, and the method was found to be linear over a concentration range of 40 to 140 μg/mL. The specificity of the method represented no interference of the excipients during the analysis, and stability testing after 24 hours also showed that the method is suitable and specific. The accuracy was between 99.93 to 99.96%, with limit of detection (LOD) and limit of quantitation (LOQ) being 0.354 μg/mL, 1.18 μg/mL, respectively. Satisfactory results were found for precision and robustness parameters during the development and validation stage for the analytical method. The proposed method was also adopted for the analysis of glimepiride tablets to improve the overall quality control. Using this method, symmetric peak shape was obtained with reasonable retention time. The retention time of glimepiride for six repetitions is 9.3 ± 0.1 minutes; the run time is 21 minutes. The proposed RP-HPLC method is a modification of the United States Pharmacopeia (USP) method, and it was found to be valid for glimepiride within concentration ranges 40 to 140 μg/mL, using C18 analytical columns, and isocratic elution with UV detection, and at 1 mL/min of flow rate.


Author(s):  
SAILAJA B ◽  
SRAVANA KUMARI K

Objective: The present work was focused on the development and validation of reverse-phase high-performance liquid chromatography (RP-HPLC) method which is simple, rapid, precise, accurate, sensitive, economical, and stability indicating for the quantitation of rosuvastatin calcium in bulk and tablet formulation. Methods: The separation was attained on Waters Symmetry C18 column with dimensions 150×4.6 mm, 5 mm particle size employing 0.1% orthophosphoric acid buffer:acetonitrile in the ratio of 55:45% v/v as mobile phase, which was pumped at a rate of 1.0 ml/min and detected at a wavelength of 241 nm. Results: The linearity of the method was demonstrated in the concentration range of 2–12 μg/ml for rosuvastatin calcium with a correlation coefficient (r2) of 0.999, percentage drug recovery was found to be 100.22–101.16%, and percentage relative standard deviation <2. Limit of detection and limit of quantitation values were found to be 0.013 μg/ml and 0.042 μg/ml, respectively, and assay of marketed tablet formulation was found to be 99.76%. Conclusion: The developed RP-HPLC method was found to be simple, specific, sensitive, rapid, linear, accurate, precise, and economical and could be used for regular quality control of rosuvastatin calcium in bulk and tablet formulation.


2020 ◽  
Vol 16 ◽  
Author(s):  
Kemal Hussien Seid ◽  
Tarekegn Berhanu ◽  
Kaleab Asres ◽  
Ayenew Ashenef

Introduction: A reverse-phase high performance liquid chromatography (RP-HPLC) method was developed and validated for the simultaneous analysis of two drugs, levamisole hydrochloride(LH) and oxyclozanide(OX), in co-formulations for veterinary use. Materials and Methods: The new HPLC method was validated per ICH and other guidelines. A C18 column was used with agradient program; eluent A was an equal mixture of methanol and acetonitrile, and eluent B a 25 mM phosphate buffer at pH 7.0 containing 30 mM sodium decanesulfonate andtriethylamine(50:50:1 v/v)then pH adjusted to 7.0 with H3PO4 [51:49 v/v] .The detection wavelength was set at 220 nm.For the final gradient program, the retention times were 8.2(for LH)and 13.6(for OX) minutes respectively at flow rate of 1 ml/min over 20 minute run time. Results: The method wasprecise, specific and robust.The correlation coefficients, R2 were 0.9998 and 0.9999 for LH and OX respectively in the ranges of 5 – 280 µg / mL.The percent y-intercepts and percent residual standard deviations were 1.6%/0.4% and 1.4%/1.0% for LH and OX, respectively. The LOD and LOQ of the method were 0.21 µg / mL and 0.62 µg / mL for LHand 0.06 µg / mL and 0.18 µg / mL for OX. The method has average accuracy of 100.5% for LH and 101.1% for OX when tested on veterinary bolus formulations, and the samples couldbe stored under typical lab conditions for about 7 days without significant degradation. Conclusion: This HPLC method is suitable forassayinglevamisole hydrochloride and oxyclozanide simultaneously from veterinary formulations.


2021 ◽  
Vol 0 (0) ◽  
Author(s):  
Katso Binang ◽  
David T. Takuwa

Abstract The aim of the study was to develop a rapid, efficient, and cheap chromatographic method for determining four selected antihypertensive active flavonoid compounds in medicinal plants in Botswana. The determination of rutin, quercetin, and kaempferol in selected medicinal plants was conducted in less than 6 min using the developed reverse phase-high performance liquid chromatography (RP-HPLC) method with a 2.7 µm Ascentis C18 express column (150 × 4.60 mm i.d) at 340, 360, and 368 nm detection wavelengths and mobile phase of methanol and 0.068% of formic acid solution in isocratic elution. Validation results showed good selectivity, linearity (r 2 > 0.99), high percentage recoveries (90.2–104.7%), and precision (% RSD < 2) for n = 3, confirming suitability of the method for determination of the investigated flavonoids in Zingiber officinale (ginger). Application of the developed RP-HPLC method was performed in selected medicinal plants (Lippia javanica ) (mosukujane), Myrothanmus flabellious (galalatshwene), and Elephantorrhiza elephantina (mositsana) used to manage hypertension by herbalists in Botswana. M. flabellious a very commonly used plant for managing hypertension was found to contain highest amounts of rutin and myricetin, whereas nothing was detected for E. elephantina.


2021 ◽  
pp. 1-11
Author(s):  
Sultan M. Alshahrani ◽  
John Mark Christensen

This study was designed to develop and validate a simple and efficient high performance liquid chromatography (HPLC) method to determine flunixin concentrations in Asian elephant’s (Elephas maximus) plasma. Flunixin was administered orally at a dose of 0.8 mg/kg, and blood samples were collected. Flunixin extraction was performed by adding an equal amount of acetonitrile to plasma and centrifuging at 4500 rpm for 25 minutes. The supernatant was removed, and flunixin was analyzed using HPLC-UV detection. Two methods were developed and tested utilizing two different mobile phases either with or without adding methanol (ACN: H2O vs. ACN: H2O: MeOH). Both methods showed excellent linearity and reproducibility. The limit of detection was 0.05 ug/ml and limit of quantification was 0.1 ug/ml. the efficiency of flunixin recovery was maximized by the addition of methanol to mobile phase (ACN: H2O: MeOH as 50:30:20) at 95% in comparison to 23% without methanol. In conclusion, adding methanol to HPLC methods for extraction of flunixin from elephants’ plasma yielded higher recovery rate than without methanol.


INDIAN DRUGS ◽  
2017 ◽  
Vol 54 (01) ◽  
pp. 35-40
Author(s):  
A. S. Bagde ◽  
V. V. Khanvilkar ◽  

The present work describes a validated reverse phase high performance liquid chromatography (RPHPLC) method for simultaneous estimation of dextromethorphan hydrobromide and quinidine sulphate in pharmaceutical dosage from. The drugs were resolved using Hemochrom Intsil C18-5U column (250×4.6) mm in isocratic mode with mobile phase methanol: water (0.08% diethylamine, 0.02% of glacial acetic acid and pH 4.4 adjusted with orthophosphoric acid) in the ratio of 70:30 V/V at a flow rate of 1.0 mL/min. Retention time of dextromethorphan hydrobromide and quinidine sulphate were 4.9±0.2 and 3.6±0.2, respectively, at 292nm. The above mentioned method was validated as per International Conference on Harmonization (ICH) guidelines. Linear responses were obtained in concentration ranges of 5-35 μg/mL for dextromethorphan hydrobromide and 4-16 μg/mL for quinidine sulphate, with correlation coefficient (r2) of 0.999 for both the drugs. A simple, selective, accurate, precise, robust and reliable RP-HPLC method thus developed and validated for simultaneous estimation of dextromethorphan hydrobromide and quinidine sulphate.


2015 ◽  
Vol 51 (4) ◽  
pp. 823-832 ◽  
Author(s):  
Francine Rodrigues Ianiski ◽  
Luciane Varini Laporta ◽  
Alexandre Machado Rubim ◽  
Cristiane Luchese

abstract A method to ensure that an analytical method will produce reliable and interpretable information about the sample must first be validated, making sure that the results can be trusted and traced. In this study, we propose to validate an analytical high performance liquid chromatography (HPLC) method for the quantitation of meloxicam loaded PEGylated nanocapsules(M-PEGNC). We performed a validation study, evaluated parameters including specificity, linearity, quantification limit, detection limit, accuracy, precision and robustness. PEGylated nanocapsules were prepared by interfacial deposition of preformed polymer, and the particle size, polydispersity index, zeta potential, pH value and encapsulation efficiency were characterized. The proposed HPLC method provides selective, linear results in the range of 1.0-40.0 μg/mL; quantification and detection limits were 1.78 μg/mL and 0.59 μg/mL, respectively; relative standard deviation for repeatability was 1.35% and intermediate precision was 0.41% and 0.61% for analyst 1 and analyst 2, respectively; accuracy between 99.23 and 101.79%; robustness between 97.13 and 98.45% for the quantification of M-PEGNC. Mean particle diameters were 261 ± 13 nm and 249 ± 20 nm, polydispersity index was 0.15 ± 0.07 and 0.17 ± 0.06, pH values were 5.0 ± 0.2 and 5.2 ± 0.1, and zeta-potential values were -37.9 ± 3.2 mV e -31.8 ± 2.8 mV for M-PEGNC and placebo(B-PEGNC), respectively. In conclusion, the proposed analytical method is suitable for the quality control of M-PEGNC. Moreover, suspensions showed monomodal size distributions and low polydispersity index indicating high homogeneity of formulations with narrow size distributions, and appropriate pH and zeta potential. The extraction process was efficient for release of meloxicam from nanostructured systems.


Sign in / Sign up

Export Citation Format

Share Document