Comparison of surfactant-mediated liquid chromatographic modes with sodium dodecyl sulphate for the analysis of basic drugs

2020 ◽  
Vol 12 (19) ◽  
pp. 2443-2452 ◽  
Author(s):  
N. Pankajkumar-Patel ◽  
E. Peris-García ◽  
M. J. Ruiz-Angel ◽  
M. C. García-Alvarez-Coque

A comprehensive overview of the performance of MLC, HSLC and MELC for the analysis of basic compounds.


2015 ◽  
Vol 17 (6) ◽  
pp. 3561-3570 ◽  
Author(s):  
M. J. Ruiz-Angel ◽  
E. Peris-García ◽  
M. C. García-Alvarez-Coque

Mixed micellar systems of Brij-35 and sodium dodecyl sulphate without an organic solvent allow the analysis of polar and moderately polar basic compounds, giving rise to a type of more sustainable RPLC.



2018 ◽  
Vol 26 (2) ◽  
pp. 058
Author(s):  
Anna P. Roswiem ◽  
Triayu Septiani

<em>Bahan<strong> </strong>baku untuk membuat baso adalah daging hewan, pada umumnya dari daging sapi, ayam, ikan dan babi. Di beberapa daerah di Indonesia terjadi kasus baso tikus. Tujuan penelitian ini adalah menguji ada tidaknya kandungan daging tikus pada produk baso yang dijual di pasar Cempaka Putih-Kecamatan Kramat Jakarta Pusat dan di pedagang baso atau mie baso di sekitar kampus Universitas YARSI Jakarta. Daging adalah protein salah satu metode untuk mengidentifikasi protein adalah metode Sodium Dodecyl Sulphate Polyacrylamide Gel Electrophoresis (SDS-PAGE).<strong> </strong>Hasil penelitian menunjukkan bahwa dari 6 sampel baso terindikasi ada 2 sampel baso dengan nomor 1 dan 5 yang dibuat dari campuran daging sapi dan tikus; ada 1 sampel baso dengan nomor 6 yang terbuat dari daging tikus; dan 2 sampel baso dengan nomor 2 dan 3 yang terbuat dari campuran sapi  dan babi, dan hanya 1 sampel baso dengan nomor sampel 4 yang benar-benar terbuat dari daging sapi.</em>



2018 ◽  
Vol 10 (6) ◽  
pp. 06013-1-06013-5 ◽  
Author(s):  
I. G. Vorobiova ◽  
◽  
Yu. A. Mirgorod ◽  
A. S. Chekadanov ◽  
◽  
...  


2020 ◽  
Vol 16 (3) ◽  
pp. 277-286
Author(s):  
Amal A. El-Masry ◽  
Mohammed E. A. Hammouda ◽  
Dalia R. El-Wasseef ◽  
Saadia M. El-Ashry

Background: The first highly sensitive, rapid and specific green microemulsion liquid chromatographic (MELC) method was established for the simultaneous estimation of fluticasone propionate (FLU) and azelastine HCl (AZL) in the presence of their pharmaceutical dosage form additives (phenylethyl alcohol (PEA) and benzalkonium chloride (BNZ)). Methods: The separation was performed on a C18 column using (o/w) microemulsion as a mobile phase which contains 0.2 M sodium dodecyl sulphate (SDS) as surfactant, 10% butanol as cosurfactant, 1% n-octanol as internal phase and 0.3% triethylamine (TEA) adjusted at pH 6 by 0.02 M phosphoric acid; with UV detection at 220 nm and programmed with flow rate of 1 mL/min. Results: The validation characteristics e.g. linearity, lower limit of quantification (LOQ), lower limit of detection (LOD), accuracy, precision, robustness and specificity were investigated. The proposed method showed linearity over the concentration range of (0.5-25 µg/mL) and (0.1-25 µg/mL) for FLU and AZL, respectively. Besides that, the method was adopted in a short chromatographic run with satisfactory resolution factors of (2.39, 3.78 and 6.74 between PEA/FLU, FLU/AZL and AZL/BNZ), respectively. The performed method was efficiently applied to pharmaceutical nasal spray with (mean recoveries ± SD) (99.80 ± 0.97) and (100.26 ± 0.96) for FLU and AZL, respectively. Conclusion: The suggested method was based on simultaneous determination of FLU and AZL in the presence of PEA and BNZ in pure form, laboratory synthetic mixture and its combined pharmaceutical dosage form using green MELC technique with UV detection. The proposed method appeared to be superior to the reported ones of being more sensitive and specific, as well as the separation was achieved with good performance in a relatively short analysis time (less than 7.5 min). Highly acceptable values of LOD and % RSD make this method superior to be used in quality control laboratories with of HPLC technique.



Author(s):  
Jonathan Welch ◽  
Joanne Wallace ◽  
Alison B. Lansley ◽  
Clive Roper


Author(s):  
B Saviana ◽  
L Pons ◽  
F Namour ◽  
D Quilliot ◽  
O Ziegler ◽  
...  


2012 ◽  
Vol 178-181 ◽  
pp. 609-612
Author(s):  
Hai Ke Feng ◽  
Hua Yu Qiu ◽  
Li Yuan Ding ◽  
Cun Jin Xu

In this paper, we followed the kinetics of methyl methacrylate (MMA) through a novel fluorescence method. The real-time measurement results show that in the regime of very low monomer contents, such as a solution containing 0.1 wt% of MMA with respect to water and with the anionic surfactant of sodium dodecyl sulphate (SDS), the kinetic of the miniemulsion could be followed by this embed fluorescence method. The processes of changing from emulsion to miniemulsion with different amount of surfactant and cosurfactant also have been monitored.



Sign in / Sign up

Export Citation Format

Share Document