scholarly journals Surface modifications of carbon nanodots reveal the chemical source of their bright fluorescence

2021 ◽  
Author(s):  
Asmita Dutta ◽  
Shimon T. Y. Trolles-Cavalcante ◽  
Annie Cleetus ◽  
Vered Marks ◽  
Alex Schechter ◽  
...  

Carbon nanodots were chemically modified to control the fluorescence and identify fluorophores.

Materials ◽  
2019 ◽  
Vol 12 (24) ◽  
pp. 4179
Author(s):  
Alexander V. Savin ◽  
Yuriy A. Kosevich

We model, with the use of the force field method, the dependence of mechanical conformations of graphene sheets, located on flat substrates, on the density of unilateral (one-side) attachment of hydrogen, fluorine or chlorine atoms to them. It is shown that a chemically-modified graphene sheet can take four main forms on a flat substrate: the form of a flat sheet located parallel to the surface of the substrate, the form of convex sheet partially detached from the substrate with bent edges adjacent to the substrate, and the form of a single and double roll on the substrate. On the surface of crystalline graphite, the flat form of the sheet is lowest in energy for hydrogenation density p < 0.21 , fluorination density p < 0.20 , and chlorination density p < 0.16 . For higher attachment densities, the flat form of the graphene sheet becomes unstable. The surface of crystalline nickel has higher adsorption energy for graphene monolayer and the flat form of a chemically modified sheet on such a substrate is lowest in energy for hydrogenation density p < 0.47 , fluorination density p < 0.30 and chlorination density p < 0.21 .


Author(s):  
George Price ◽  
Lizardo Cerezo

Ultrastructural defects of ciliary structure have been known to cause recurrent sino-respiratory infection concurrent with Kartagener's syndrome. (1,2,3) These defects are also known to cause infertility in both males and females. (4) Overall, the defects are defined as the Immotile, or Dyskinetic Cilia Syndrome (DCS). Several ultrastructural findings have been described, including decreased number of cilia, multidirection orientation, fused and compound cilia, membrane blebs, excess matrix in the axoneme, missing outer tubular doublets, translocated doublets, defective radial spokes and dynein arms. A rare but noteworthy ultrastructural finding in DCS is the predominance of microvilli-like structures on the luminal surface of the respiratory epithelium. (5,6) These permanent surface modifications of the apical respiratory epithelium no longer resemble cilia but reflect the ultrastructure of stereocilia, similar to that found in the epidydimal epithelium. Like microvilli, stereocilia are devoid of microtubular ultrastructure in comparison with true cilia.


1989 ◽  
Vol 61 (01) ◽  
pp. 131-136 ◽  
Author(s):  
Richard A Harvey ◽  
Hugh C Kim ◽  
Jonathan Pincus ◽  
Stanley Z Trooskin ◽  
Josiah N Wilcox ◽  
...  

SummaryTissue plasminogen activator labeled with radioactive iodine (125I-tPA) was immobilized on vascular prostheses chemically modified with a thin coating of water-insoluble surfactant, tridodecylmethylammonium chloride (TDM AC). Surfactant- treated Dacron, polytetrafluoroethylene (PTFE), silastic, polyethylene and polyurethane bound appreciable amounts of 125I- tPA (5-30 μg 125I-tPA/cm2). Upon exposure to human plasma, the amount of 125I-tPA bound to the surface shows an initial drop during the first hour of incubation, followed by a slower, roughly exponential release with a t½ of appoximately 75 hours. Prostheses containing bound tPA show fibrinolytic activity as measured both by lysis of clots formed in vitro, and by hydrolysis of a synthetic polypeptide substrate. Prior to incubation in plasma, tPA bound to a polymer surface has an enzymic activity similar, if not identical to that of the native enzyme in buffered solution. However, exposure to plasma causes a decrease in the fibrinolytic activity of both bound tPA and enzyme released from the surface of the polymer. These data demonstrate that surfactant-treated prostheses can bind tPA, and that these chemically modified devices can act as a slow-release drug delivery system with the potential for reducing prosthesis-induced thromboembolism.


1991 ◽  
Vol 223 ◽  
Author(s):  
Neeta Agrawal ◽  
R. D. Tarey ◽  
K. L. Chopra

ABSTRACTArgon plasma exposure has been used to induce surface chemical modification of aluminium thin films, causing a drastic change in etch rate in standard HNO3/CH3COOH/H3PO4 etchant. The inhibition period was found to increase with power and Ar plasma exposure time. Auger electron and x-ray photoelectron spectroscopies have indicated formation of an aluminium fluoride (AlF3) surface layer due to fluorine contamination originating from the residue left in the plasma chamber during CF4 processing. The high etch selectivity between unexposed and argon plasma exposed regions has been exploited as a new technique for resistless patterning of aluminium.


2012 ◽  
pp. 141208072802005
Author(s):  
Fabiano Ribeiro Cirano ◽  
ADRIANE TOGASHI ◽  
MARCIA MARQUES ◽  
FRANCISCO PUSTIGLIONI ◽  
LUIZ LIMA

Sign in / Sign up

Export Citation Format

Share Document