Discrimination of cysteamine from mercapto amino acids through isoelectric point-mediated surface ligand exchange of β-cyclodextrin-modified gold nanoparticles

2020 ◽  
Vol 8 (18) ◽  
pp. 4039-4045
Author(s):  
Quanbao Ma ◽  
Xun Fang ◽  
Junting Zhang ◽  
Lili Zhu ◽  
Xiabing Rao ◽  
...  

A pI-mediated R6G-β-CD@AuNPs system was designed for the first time for the discrimination of CA from GSH/Cys/Hcy in human serum samples.

Langmuir ◽  
2015 ◽  
Vol 31 (14) ◽  
pp. 4054-4062 ◽  
Author(s):  
Ryo Iida ◽  
Hitoshi Kawamura ◽  
Kenichi Niikura ◽  
Takashi Kimura ◽  
Shota Sekiguchi ◽  
...  

2006 ◽  
Vol 52 (7) ◽  
pp. 1389-1394 ◽  
Author(s):  
Zhiliang Jiang ◽  
Shuangjiao Sun ◽  
Aihui Liang ◽  
Wenxin Huang ◽  
Aimiao Qin

Abstract Background: Apolipoprotein AI (ApoAI) and ApoB are risk indicators of cardiovascular disease. We describe the use of immunoresonance scattering to measure the ApoAI and ApoB in serum. Methods: We used a trisodium citrate method to prepare 9.0-nm gold nanoparticles labeled with goat anti-human ApoAI and ApoB antibodies. The immune reaction between gold-labeled antibodies and antigens took place in Na2HPO4-NaH2PO4 buffer solution (pH 6.4 for ApoAI and pH 6.0 for ApoB) in the presence of 75 g/L polyethylene glycol (PEG). We used a transmission electron microscope to observe the shape of the gold nanoparticles. Results were compared with those obtained by immunoturbidimetric methods. Twenty-five human serum samples were assayed by the immunoresonance scattering assay preset with the data indicated and by an immunoturbidimetric assay. Results: The presence of PEG greatly enhanced the intensity of resonance-scattering peaks at 560 nm. The intensity (ΔI) was proportional to concentration at 0.00833–0.3333 mg/L ApoAI and 0.00197–0.1972 mg/L ApoB. The detection limits were 2.04 and 0.96 μg/L for ApoAI and ApoB, respectively. The results for human serum samples were in agreement with those obtained with an immunoturbidimetric method. Linear regression analysis revealed a correlation coefficient, slope, and intercept of 0.915, 0.966, and 68.53 mg/L, respectively, for ApoAI and 0.919, 0.996, and 15.46 mg/L for ApoB. Conclusion: This method showed high sensitivity and good selectivity for quantitative determination of ApoAI and ApoB in human serum, with satisfactory results.


2019 ◽  
Vol 15 (6) ◽  
pp. 678-684
Author(s):  
Biljana Nigović ◽  
Jakov Vlak

Background: High uric acid serum level, hyperuricemia, is now associated with many diseases such as gout, chronic kidney disease, hypertension, coronary artery disease and diabetes. Febuxostat is a novel selective xanthine oxidase inhibitor approved for the treatment of hyperuricemia. Objective: The aim of this study was to develop a first analytical method for the simultaneous determination of febuxostat and uric acid. Methods: An unmodified boron-doped diamond electrode provided concurrent quantitation of drug at low levels and uric acid, which has clinical significance in the diagnosis and therapy of hyperuricemia, at relatively high concentrations. The direct square-wave voltammetric method was applied to the analysis of both analytes in human serum samples. Results: Under the optimized conditions, the linear response of peak current on febuxostat concentration was achieved in the range from 7.5 × 10-7 to 3 × 10-5 M, while uric acid showed two linear ranges of 5 × 10-6 - 5 × 10-5 M and 5 × 10-5 - 2 × 10-4 M. The method was successfully utilised for quantification of both analytes in human serum samples. Good recoveries were obtained without interference from common inorganic cations and anions as well as glucose, dopamine, ascorbic and folic acids at concentrations expected in physiological conditions. Conclusion: The great benefits of developed method are fast analysis (only 7.5 s for run), low cost and simplicity of performance.


1990 ◽  
Vol 126 (1) ◽  
pp. 159-168 ◽  
Author(s):  
A. N. Thakur ◽  
R. Coles ◽  
A. Sesay ◽  
B. Earley ◽  
H. S. Jacobs ◽  
...  

ABSTRACT A previously described in-vitro rat granulosa cell plasminogen activator bioassay for FSH has been modified and applied in the assay of human serum. This modified method consists of exposing the diethylstilboestrol-stimulated granulosa cells from 25- to 26-day-old rats to FSH or test substance for 3·5 h in wells coated with 125I-labelled fibrinogen and treated with thrombin. Following stimulation with FSH, the dose-related production of plasminogen activator was measured as the degree of 125I-labelled fibrinolysis in the presence of added plasminogen. Using the urinary FSH/LH bioassay reference preparation as the assay standard, the useful range of the assay was 0·3–15IU/l, with an assay sensitivity of 0·3 IU/l. As determined using purified glycoprotein hormone preparations, the assay was highly specific for FSH. The minor degree of FSH bioactivity measured in some of the hormone preparations was accounted for by the amount of FSH contamination in these preparations. To abolish interference caused by unknown serum factors, we heat-treated the serum samples for 15 min at 56 °C before the assay. The results indicated that neither immunoreactivity nor bioactivity was affected by this treatment. Furthermore, heat-treated human sera gave responses parallel to the standard curve at the three dose levels (2, 4 and 8 μl) studied. We used this bioassay to estimate the FSH-like bioactivity in 15 human serum samples. The estimates of immunoreactive FSH in these samples correlated well with the corresponding FSH bioactivity (r = 0·745, n = 15 and P < 0·05). The results indicate that with this sensitive and rapid (completed within 24 h) bioassay, it should be possible to measure FSH bioactivity in heat-treated human serum samples. Journal of Endocrinology (1990) 126, 159–168


2009 ◽  
Vol 15 ◽  
pp. 232-234 ◽  
Author(s):  
E.M Mendes do Nascimento ◽  
S. Colombo ◽  
T.K. Nagasse-Sugahara ◽  
R.N. Angerami ◽  
M.R. Resende ◽  
...  

2016 ◽  
Vol 129 ◽  
pp. 205-212 ◽  
Author(s):  
Adrian Marcelo Granero ◽  
Gastón Darío Pierini ◽  
Sebastián Noel Robledo ◽  
María Susana Di Nezio ◽  
Héctor Fernández ◽  
...  

mSphere ◽  
2018 ◽  
Vol 3 (6) ◽  
Author(s):  
Gregory R. Wiedman ◽  
Yanan Zhao ◽  
David S. Perlin

ABSTRACT Clinicians need a better way to accurately monitor the concentration of antimicrobials in patient samples. In this report, we describe a novel, low-sample-volume method to monitor the azole-class antifungal drug posaconazole, as well as certain other long-chain azole-class antifungal drugs in human serum samples. Posaconazole represents an important target for therapeutic drug monitoring (TDM) due to its widespread use in treating invasive fungal infections and well-recognized variability of pharmacokinetics. The current “gold standard” requires trough and peak monitoring through high-pressure liquid chromatography (HPLC) or liquid chromatography-tandem mass spectroscopy (LC-MS/MS). Other methods include bioassays that use highly susceptible strains of fungi in culture plates or 96-well formats to monitor concentrations. Currently, no method exists that is both highly accurate in detecting free drug concentrations and is also rapid. Herein, we describe a new method using reduced graphene oxide (rGO) and a fluorescently labeled aptamer, which can accurately assess clinically relevant concentrations of posaconazole and other long-chain azole-class drugs in little more than 1 h in a total volume of 100 µl. IMPORTANCE This work describes an effective assay for TDM of long-chain azole-class antifungal drugs that can be used in diluted human serum samples. This assay will provide a quick, cost-effective method for monitoring concentrations of drugs such as posaconazole that exhibit well-documented pharmacokinetic variability. Our rGO-aptamer assay has the potential to improve health care for those struggling to treat fungal infections in rural or resource-limited setting.


2016 ◽  
Vol 8 (2) ◽  
pp. 249-255 ◽  
Author(s):  
B. L'Homme ◽  
J.-F. Focant

Human exposure to POPs is of concern and typical biomonitoring studies require large amounts of blood (5–75 mL) from participants. As a proof of concept, we developed a miniaturized method based on MEPS and CZC applied to GC-HRTOFMS for the measurement of markers of exposure (PCB-153, DDE) in 20 μL human serum samples.


Sign in / Sign up

Export Citation Format

Share Document