scholarly journals Measuring relative abundances in the solar corona with optimised linear combinations of spectral lines

2019 ◽  
Vol 632 ◽  
pp. A20
Author(s):  
Natalia Zambrana Prado ◽  
Éric Buchlin

Context. Elemental abundances in some coronal structures differ significantly from photospheric abundances, with a dependence on the first ionization potential (FIP) of the element. Measuring these FIP-dependent abundance biases is important for coronal and heliospheric physics. Aims. We aim to build a method for optimal determination of FIP biases in the corona from spectroscopic observations in a way that is in practice independent from differential emission measure (DEM) inversions. Methods. We optimised linear combinations of spectroscopic lines of low-FIP and high-FIP elements so that the ratio of the corresponding radiances yields the relative FIP bias with good accuracy for any DEM in a small set of typical DEMs. Results. These optimised linear combinations of lines allow retrieval of a test FIP bias map with good accuracy for all DEMs in the map. The results also compare well with a FIP bias map obtained from observations using a DEM-dependent method. Conclusions. The method provides a convenient, fast, and accurate way of computing relative FIP bias maps. It can be used to optimise the use of existing observations and the design of new observations and instruments.

2020 ◽  
Author(s):  
Natalia Zambrana Prado ◽  
Eric Buchlin ◽  
Hardi Peter

<p>With the launches of Parker Solar Probe and Solar Orbiter, we are closer than ever to linking solar activity on the surface and in the corona to the inner heliosphere. In this quest, relative abundance measurements will be key as different structures on the Sun have different abundances as a consequence of the FIP (First Ionization Potential) effect.</p><p>Comparing in-situ and remote sensing composition data, coupled with modeling, will allow us to trace back the source of heliospheric plasma. Solar Orbiter has a unique combination of in-situ and remote sensing instruments that will hopefully allow us to make such comparisons.</p><p>High telemetry will not always be available with SPICE (SPectral Imaging of the Coronal Environment), the EUV spectrometer on board Solar Orbiter. We have therefore developed a method for measuring relative abundances that is both telemetry efficient and reliable. Unlike methods based on Differential Emission Measure (DEM) inversion, the Linear Combination Ratio (LCR) method does not require a large number of spectral lines. This new method is based on optimized linear combinations of only a few UV spectral lines. We present some abundance diagnostics applied to synthesized radiances of spectral lines observable by SPICE.</p>


Atoms ◽  
2021 ◽  
Vol 9 (2) ◽  
pp. 29
Author(s):  
Sylvie Sahal-Bréchot

The present paper revisits the determination of the semi-classical limit of the Feshbach resonances which play a role in electron impact broadening (the so-called “Stark“ broadening) of isolated spectral lines of ionized atoms. The Gailitis approximation will be used. A few examples of results will be provided, showing the importance of the role of the Feshbach resonances.


1996 ◽  
Vol 175 ◽  
pp. 363-366
Author(s):  
Koujun Yamashita

X-ray emissions from clusters are most likely originated from a thin hot plasma in a collisional ionization equilibrium. The optical depth of continuum component is order of 10–3, whereas that of emission lines is around unity. Present emission models used for spectral fitting can not estimate this effect, so that the determination of elemental abundances seems to include large uncertainty. The high resolution spectroscopy with ASCA gives a clue to investigate the physical state of hot intracluster gas and a impact to reconsider the basic atomic processes. This is important issue to deeply understand the structure, formation and evolution of clusters, and the origin of intracluster gas.


Author(s):  
Junxiao Wang ◽  
Shuqing Wang ◽  
Lei Zhang ◽  
Maogen Su ◽  
Duixiong Sun ◽  
...  

Abstract We proposed a theoretical spatio-temporal imaging method, which was based on the thermal model of laser ablation and the two-dimensional axisymmetric multi-species hydrodynamics model. By using the intensity formula, the integral intensity of spectral lines could be calculated and the corresponding images of intensity distribution could be drawn. Through further image processing such as normalization, determination of minimum intensity, combination and color filtering, a relatively clear species distribution image in the plasma could be obtained. Using the above method, we simulated the plasma ablated from Al-Mg alloy by different laser energies under 1 atm argon, and obtained the theoretical spatio-temporal distributions of Mg I, Mg II, Al I, Al II and Ar I species, which are almost consistent with the experimental results by differential imaging. Compared with the experimental decay time constants, the consistency is higher at low laser energy, indicating that our theoretical model is more suitable for the plasma dominated by laser-supported combustion wave.


INDIAN DRUGS ◽  
2017 ◽  
Vol 54 (03) ◽  
pp. 44-51
Author(s):  
B. Sabbagh ◽  
B. V. S. Lokesh ◽  
G. A. Akouwah ◽  

Two methods were developed for the determination of dapagliflozin (DAPA) in pure form and in tablets. The procedure utilized was UV-Visible Spectroscopy and RP-HPLC with PDA detector to quantify DAPA in bulk and tablets. The sensitive linear range was identified for both methods within 0.5-5.0μg/mL. The linear regression analysis was identified for both methods with correlation coefficient(r)>0.99. The LOD and LOQ values were found to be 0.05 μg/mL and 0.5 μg/mL for the method by UV-Spectroscopy. The molar absorptivity (ε) was calculated as 1.27 X 105 L.mol-1cm-1. The RP-HPLC method produced LOD and LOQ values of 1.0 ng/mL and 0.5 μg/mL. Both methods were simple, precise, reproducible to quantify the amount of unknown in bulk as well as in tablets and estimated accurately within the range of 100.0±0.5%. Statistical analysis was performed on the data obtained. There was no significant difference between the developed and reported methods with p>0.05. Both methods can be applied for routine analysis of DAPA in bulk and tablets with good accuracy and precision.


2015 ◽  
Vol 1095 ◽  
pp. 218-221
Author(s):  
Lan Ma ◽  
Guang He Qin ◽  
Qiong Yu ◽  
Jing Zhou

A Method was studied for the determination of Al、Cu、Ni in Zr-based amorphous alloy by inductively coupled plasma atomic emission spectrometry (ICP-AES). Samples were dissolved by hydrochloric acid,nitric acid and hydrofluoric acid,analytical spectral lines for aluminum,copper,nickle are 308.215nm,327.396nm and 231.604nm.Interference of zinc was eliminated by the matrix-matching method, the experiments were done with optimized Operating Parameters. The correlation coefficients of the calibration curve are all 0.999,detection limits are 0.0010%,0.005% and 0.0006% respectively,and the range of recovery is 98%-104%.


2003 ◽  
pp. 69-74 ◽  
Author(s):  
Oliver Vince ◽  
Istvan Vince

By using the Blackwell program package by R.O. Gray, the metallicity of the HR7914 solar-like star was determined. The program package utilizes measured equivalent widths of several chosen neutral iron spectral lines from the observed spectra, appropriate atomic and spectral line parameters and adequate Kurucz?s stellar atmosphere models. The method is based on determination of the minimum dispersion of the iron abundance versus microturbulent velocity functions for the selected neutral iron spectral lines. The spectra were observed at National Astronomical Observatory Rozhen (NAO Rozhen), Bulgaria, using the 2m-telescope and Coude spectrograph. They were reduced with the IRAF program package. The measurement of the spectral line parameters was done with the SPE program package. The metallicity of the HR7914 solar-like star was determined to be 0.02.


2021 ◽  
pp. 171-175
Author(s):  
A. Murmantsev ◽  
A. Veklich ◽  
V. Boretskij

This work is devoted to spectroscopy peculiarities of electric arc discharge plasma with iron vapours. The solution of the main issue of optical emission spectroscopy, namely, selection of iron spectral lines, to study the parameters of non-uniform and non-steady-state plasma source, was considered within this paper. Specifically, the Boltzmann plots technique was used for detailed analysing of application possibility of Fe I spectral lines as well as for determination of plasma temperature. The spatial profiles of selected spectral line emission intensities were used to measure the radial distributions of plasma temperature of free-burning arc discharge between consumable electrodes at 3.5 A.


Author(s):  
Zeinab Adel Nasr ◽  
Noha S. Said ◽  
Sawsan A. Abdel-Razeq

Aims: Two spectrophotometric methods were developed and validated for the determination of sofosbuvir in presence of its alkaline degradate. Study Design: Ratio difference and ratio derivative methods were assisted for determination of sofosbuvir in presence of its alkaline degradate, laboratory-prepared mixtures and in tablet dosage forms. Place and Duration of Study: Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy (Girls), Al - Azhar University, between December 2019 and January 2020. Methodology: Two analytical methods were achieved and validated for the quantitative determination of Sofosbuvir in presence of its alkaline degradate. The first method was ratio difference (RD) method, where the UV absorption spectra of different concentrations of sofosbuvir were divided by the spectrum of a certain concentration (15 µg mL-1) as a devisor of its alkaline degradate to get the ratio difference spectra. Afterwards, the peak amplitudes difference between 253.7 and 243.5 nm were measured. The second method was the ratio derivative (1DR) method, where the first derivative of the ratio spectra (1DR) was obtained and its amplitude was measured at 247 and 268 nm. Good linearity was obtained over the concentration range of 3-15 µg mL-1 for the proposed methods. The proposed procedures were adopted for the selective determination of intact Sofosbuvir in presence of up to 80% of its degradation product. Sofosbuvir was exposed to different conditions as alkaline, acidic and oxidative degradation. Results: The proposed methods were developed and validated with good linearity range of 3-15 µg mL-1 for both methods, and also with good accuracy and precision. And the obtained results were statistically compared to those obtained by the reported method. Conclusion: Sofosbuvir was successfully determined by the proposed ratio difference and ratio derivative methods in bulk powder, laboratory prepared mixtures and tablet dosage form with good accuracy and precision. The methods were validated according to ICH guidelines. The results obtained were compared with those of the reported method and were found to be in good agreement.


Sign in / Sign up

Export Citation Format

Share Document