scholarly journals Evaluation and Determination of Heavy Metals (Mercury, Lead and Cadmium) in Human Breast Milk

2013 ◽  
Vol 1 ◽  
pp. 41037 ◽  
Author(s):  
Atousa Abdollahi ◽  
Fariba Tadayon ◽  
Mooud Amirkavei
1989 ◽  
Vol 35 (10) ◽  
pp. 2127-2129 ◽  
Author(s):  
Y Bergqvist ◽  
L Karlsson ◽  
L Fohlin

Abstract This simple method of centrifugal analysis for total protein in human breast milk is based on the change in the wavelength of the absorbance maximum of Coomassie Brilliant Blue G-250 when the dye is bound to protein. Within-run and between-day CVs were 3.8% and 4.8%, respectively. Compared with a micro-Kjeldahl method for determination of total nitrogen, the coefficient of correlation was 0.99.


2020 ◽  
Vol 321 ◽  
pp. 126692
Author(s):  
A. Arias-Borrego ◽  
B. Callejón-Leblic ◽  
G. Rodríguez-Moro ◽  
I. Velasco ◽  
J.L. Gómez-Ariza ◽  
...  

2004 ◽  
Vol 18 (8) ◽  
pp. 501-507 ◽  
Author(s):  
Yen Sun ◽  
Miki Irie ◽  
Naoya Kishikawa ◽  
Mitsuhiro Wada ◽  
Naotaka Kuroda ◽  
...  

2020 ◽  
Vol 103 (4) ◽  
pp. 1029-1042
Author(s):  
Tomasz Tuzimski ◽  
Szymon Szubartowski ◽  
Renata Gadzała-Kopciuch ◽  
Andrzej Miturski ◽  
Monika Wójtowicz-Marzec ◽  
...  

Abstract Background Determination of bisphenols released from packaging material is undoubtedly a difficult and tricky task, requiring the chemical analyst to develop an individual approach to obtain reliable analytical information. Objective QuECHERS (Quick, Easy, Cheap, Effective, Rugged, and Safe)/dispersive solid-phase extraction (d-SPE) technique and high performance liquid chromatography (HPLC) coupled with modern detection techniques such as diode-array detector (DAD), fluorescence detector (FLD) or tandem mass spectrometry (MS/MS) for the determination of bisphenols such as bisphenol A (BPA), bisphenol S (BPS), bisphenol F (BPF), bisphenol B (BPB), 2-[[4-[2-[4-(Oxiran-2-ylmethoxy)phenyl]propan-2yl]phenoxy] methyl]oxirane (BADGE), 3-[4-[2-[4-(Oxiran-2-ylmethoxy)phenyl]propan-2-yl]phenoxy]propane-1,2-diol (BADGE*H2O), 3-[4-[2-[4-(2,3-Dihydroxypropoxy)phenyl]propan-2-yl]phenoxy]propane-1,2-diol (BADGE*2H2O), 1-Chloro-3-[4-[2-[4-(3-chloro-2-hydroxypropoxy)phenyl] propan-2-yl]phenoxy]propan-2-ol (BADGE*2HCl) in human breast milk samples have been performed. Methods For the analysis of total analytes, prior to the extraction with acetonitrile, a deconjugation step was implemented in a tube by adding 1 mL of the enzymatic solution with the β-Glucuronidase to 5 mL of sample. The mix was homogenized and incubated for 17 h at 37°C. Ten milliliters of acetonitrile, and a QuEChERS salt packet with 4 g anhydrous MgSO4 and 1 g NaCl were added. During the d-SPE step the extract was transferred into tube with 30 mg Z-Sep and 50 mg PSA (and also 150 mg MgSO4 for LC-MS/MS analysis). MeOH–water (20:80, v/v) were added to the dry residue and the extract was reconstituted in 150 µL (25-fold analytes pre-concentration is achieved). Next bisphenols were identified by HPLC-DAD-FLD and quantified by LC-MS/MS equipment. Conclusions During the bisphenols HPLC-DAD-FLD analysis, from 6 min a reinforcement of 15 was used, which allowed analytes to be identified at 750 pg/mL. Application of LC-MS/MS allowed quantification of bisphenols in the range from 2.12 to 116.22 ng/mL in a total 27 human breast milk samples. Highlights First QuEChERS/d-SPE coupled with HPLC-DAD-FLD or LC-MS/MS method for the quantification of bisphenols and its analogues in breast milk Faster and cheaper alternative to traditional extraction methods The method was applied for the first biomonitoring of bisphenols and its analogues in breast milk.


Bioanalysis ◽  
2021 ◽  
Author(s):  
Sıdıka Ertürk Toker ◽  
Gamze Ergin Kızılçay ◽  
Olcay Sagirli

Aim: A new HPLC method with fluorescence detection has been developed and validated for the determination of levofloxacin, one of the fluoroquinolone class antibiotics, in breast milk. Materials & methods: Chromatographic separation was carried out on a reversed phase C18 column with acetonitrile and 10 mM o-phosphoric acid (25:75,v/v) mobile phase composition. Moxifloxacin was used as internal standard and the peaks were detected by fluorescence detection. Results & conclusion: Calibration graph was found linearly within the range of 2.5–500 ng/ml. Limit of detection and limit of quantification were found to be 0.63 and 2.11 ng/ml, respectively. Mean absolute recovery was 96.18%. The developed method has been successfully applied to the determination of levofloxacin in human breast milk taken from two healthy volunteers.


2017 ◽  
Vol 45 (4) ◽  
pp. 593-600 ◽  
Author(s):  
Xiao-Mei HUANG ◽  
Sheng-Tao MA ◽  
Jun-Tao CUI ◽  
Pei LI ◽  
Xiang-Ying ZENG ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document