scholarly journals DALY indicator as an assessment tool for indoor air quality impact on human health

2018 ◽  
Vol 49 ◽  
pp. 00133 ◽  
Author(s):  
Monika Wysocka

The quality of indoor environment is an extremely important issue, because people spend large parts of the day inside buildings. The quality of the indoor environment is largely dependent on the quality of indoor air. The parameters of the air we breathe affect our health and comfort of room use. Currently, when energy efficiency is a priority, it is difficult to maintain comfort and conditions appropriate for human health. The artificial environment in a room and related inadequate air quality cause many diseases, such as asthma, lung diseases, cardiovascular diseases, as well as poor well-being and reduced productivity. The Disability Adjusted Life Years (DALY) indicator means “loss of life corrected by disability” and is widely used by the World Health Organization to measure a disease burden on the population and identify the causes of a disease. The aim of the article is to present the structure of the DALY indicator and its suitability to assess the impact of indoor air quality on human health. The most frequent diseases caused by low quality of internal air were analysed based on statistical data. In addition, the possibilities of ventilation solutions have been presented, leading to the improvement of air quality in indoor environment.

Author(s):  
Shuo Zhang ◽  
D Mumovic ◽  
Samuel Stamp ◽  
Katherine Curran ◽  
Elizabeth Cooper

Considering the alarming rise in the rate of asthma and respiratory diseases among school children, it is of great importance to investigate all probable causes. Outside of the home, children spend most of their time in school. Many studies have researched the indoor environmental quality of primary and secondary school buildings to determine the exposure of school children to indoor air pollution. However, studies of very young children in nurseries are scarce. Unlike at elementary schools or universities, children in nurseries are more vulnerable due to their physiology, inability to articulate discomfort and to adapt their behaviour to avoid exposures. This article reviews current studies on the indoor environment in nurseries. It summarizes air pollution levels and related environmental and behavioural factors in nurseries that have been reported in the literature. Additionally, exposure to indoor air pollution and related potential health outcomes are examined. This review concludes that indoor air pollution in nurseries often exceeds current guidelines, and designers and policymakers should be made aware of the impact on the health and wellbeing of children in nurseries. Proper interventions and guidelines should be considered to create a healthy indoor environment for nursery children. Practical application: Previous IAQ assessments have mainly focused on indoor temperatures and CO2 levels. Data on comprehensive monitoring (including PMs, NO2, O3 and other pollutants) of indoor air quality of nurseries are scarce. Particularly in the UK, studies about indoor air quality in nurseries have not been founded. This paper categorized relevant articles according to the focus of the study, to provide evidence to a better understanding of current indoor air quality in nursery environments.


2016 ◽  
Vol 89-90 ◽  
pp. 138-146 ◽  
Author(s):  
Zheming Tong ◽  
Yujiao Chen ◽  
Ali Malkawi ◽  
Gary Adamkiewicz ◽  
John D. Spengler

2012 ◽  
Vol 518-523 ◽  
pp. 4435-4438
Author(s):  
Da Hua Jiang ◽  
Zhi Hua Wang ◽  
Fa En Shi ◽  
Ru Shan Ren

It is of great importance to study the impact of the cooking generated contaminants on the indoor air quality in the kitchen since cooking is regarded as the main source of indoor contaminants. This study aims investigate and analysis the indoor air quality of kitchen with using CFD numerical analysis method via the velocity, temperature, humidity CO2 concentration .It is concluded that The temperature distribution are large difference in the kitchen and the maximum value is up to 324K on the work area which near the cooking ,and the CO2 concentration which is close to the stove is 1420ppm,1370ppm, 1470ppm respectively, and it is more than the acceptance criteria (CO2<1000ppm) 42%,37% and 47% respectively. It is serious impact on the staff's physical health.


Author(s):  
Venu Shree ◽  
Bhanu M. Marwaha ◽  
Pamita Awasthi

The building provides shelter to live and most people spend their 85-90% time indoors. Therefore, it is quite important to ensure that the condition of the indoor environment is healthy for its living being. There are a number of methods to evaluate indoor air pollution of built spaces by performing experiments or doing it computationally. In this study, a review of computational studies carried out to evaluate the impact of different parameters like airflow pattern, indoor and outdoor contaminant concentrations etc., on indoor air quality (IAQ) of different type of buildings was done. Some commonly used software’s for the study of IAQ were also discussed.


2017 ◽  
Vol 12 (2) ◽  
pp. 129-137
Author(s):  
Petr Komínek ◽  
Jan Weyr ◽  
Jiří Hirš

Abstract Indoor environment has huge influence on person’s health and overall comfort. It is of great importance that we realize how essential indoor air quality is, considering we spend on average as much as 90% of our time indoors. There are many factors that affect indoor air quality: specifically, inside air temperature, relative humidity, and odors to name the most important factors. One of the key factors indicating indoor air quality is carbon dioxide (CO2) level. The CO2 levels, measured in prefab apartment buildings, indicates substantial indoor air quality issues. Therefore, a proper education of the occupants is of utmost importance. Also, great care should be directed towards technical and technological solutions that would ensure meeting the normative indoor environment criteria, especially indoor air CO2 levels. Thanks to the implementation of new emerging autonomous technologies, such as Internet of Things (IoT), monitoring in real-time is enhanced. An area where IoT plays a major role is in the monitoring of indoor environment. IoT technology (e.g. smart meters and sensors) provide awareness of information about the quality of indoor environment. There is a huge potential for influencing behaviour of the users. Through the web application, it is possible to educate people and ensure fresh air supply.


2017 ◽  
Vol 25 (2) ◽  
pp. 1-6
Author(s):  
Imrich Sánka ◽  
Veronika Földváry

Abstract This study investigates the impact of energy renovation on the indoor air quality of an apartment building during the heating season. The study was performed in one residential building before and after its renovation. An evaluation of the indoor air quality was performed using objective measurements and a subjective survey. The concentration of CO2 was measured in the bedrooms, and a sampling of the total volatile compounds (TVOC) was performed in the living rooms of the selected apartments. Higher concentrations of CO2 and TVOC were observed in the residential building after its renovation. The concentrations of CO2, and TVOC in some of the cases exceeded the recommended maximum limits, especially after implementing energy-saving measures on the building. The average air exchange rate was visibly higher before the renovation of the building. The current study indicates that large-scale renovations may reduce the quality of an indoor environment in many apartments, especially in the winter season.


2019 ◽  
Vol 68 (1-2) ◽  
pp. 12-16
Author(s):  
Martina Zorić ◽  
Mitar Simić ◽  
Saša Orlović ◽  
Emina Mladenović ◽  
Zdenka Babić

Summary Ecosystem services have been the focus of recent research on ecology, biodiversity and human health. As most of this research has placed emphasis on natural ecosystems, there is a lack of data on the effect of indoor and urban ecosystems on both human health and the quality of human life. One of the most common health issues associated with urban and indoor spaces is the quality of air. Considering that humans spend most of their time indoors, accompanied by a lack of fresh air due to industry growth and environmental degradation, there is an obvious need for a non-invasive and non-obtrusive air purification system. This paper presents the results of the indoor air quality monitoring under non-controlled conditions, i.e. the changes in air quality induced by the common indoor ornamental plant Sansevieria trifasciata ‘Laurentii’. The following air quality parameters were observed: the relative humidity and temperature of air, as well as the concentrations of carbon-dioxide, methane and overall VOCs. Measurements were performed using the commercial CO2 data logger Extech SD800 and the in-house developed Arduino Uno-based measuring device with different sensors. The results obtained show the changes in the indoor air quality relative to the presence or absence of the selected plants. A sudden increase in the overall VOC (NH3, NOx, benzene and smoke), methane and carbon-dioxide concentrations was recorded after the plants were removed from the indoor space. The purpose of this research is to form a basis for designing a biological purification system as a low-cost and environment-friendly method for the monitoring and purification of indoor air.


Climate ◽  
2021 ◽  
Vol 9 (2) ◽  
pp. 32
Author(s):  
Priyadarsini Rajagopalan ◽  
Nigel Goodman

Exposure to bushfire smoke is associated with acute and chronic health effects such as respiratory and cardiovascular disease. Residential buildings are important places of refuge from bushfire smoke, however the air quality within these locations can become heavily polluted by smoke infiltration. Consequently, some residential buildings may offer limited protection from exposure to poor air quality, especially during extended smoke events. This paper evaluates the impact of bushfire smoke on indoor air quality within residential buildings and proposes strategies and guidance to reduce indoor levels of particulates and other pollutants. The paper explores the different monitoring techniques used to measure air pollutants and assesses the influence of the building envelope, filtration technologies, and portable air cleaners used to improve indoor air quality. The evaluation found that bushfire smoke can substantially increase the levels of pollutants within residential buildings. Notably, some studies reported indoor levels of PM2.5 of approximately 500µg/m3 during bushfire smoke events. Many Australian homes are very leaky (i.e., >15 ACH) compared to those in countries such as the USA. Strategies such as improving the building envelope will help reduce smoke infiltration, however even in airtight homes pollutant levels will eventually increase over time. Therefore, the appropriate design, selection, and operation of household ventilation systems that include particle filtration will be critical to reduce indoor exposures during prolonged smoke events. Future studies of bushfire smoke intrusion in residences could also focus on filtration technologies that can remove gaseous pollutants.


2021 ◽  
Vol 13 (8) ◽  
pp. 4139
Author(s):  
Muriel Diaz ◽  
Mario Cools ◽  
Maureen Trebilcock ◽  
Beatriz Piderit-Moreno ◽  
Shady Attia

Between the ages of 6 and 18, children spend between 30 and 42 h a week at school, mostly indoors, where indoor environmental quality is usually deficient and does not favor learning. The difficulty of delivering indoor air quality (IAQ) in learning facilities is related to high occupancy rates and low interaction levels with windows. In non-industrialized countries, as in the cases presented, most classrooms have no mechanical ventilation, due to energy poverty and lack of normative requirements. This fact heavily impacts the indoor air quality and students’ learning outcomes. The aim of the paper is to identify the factors that determine acceptable CO2 concentrations. Therefore, it studies air quality in free-running and naturally ventilated primary schools in Chile, aiming to identify the impact of contextual, occupant, and building design factors, using CO2 concentration as a proxy for IAQ. The monitoring of CO2, temperature, and humidity revealed that indoor air CO2 concentration is above 1400 ppm most of the time, with peaks of 5000 ppm during the day, especially in winter. The statistical analysis indicates that CO2 is dependent on climate, seasonality, and indoor temperature, while it is independent of outside temperature in heated classrooms. The odds of having acceptable concentrations of CO2 are bigger when indoor temperatures are high, and there is a need to ventilate for cooling.


Sign in / Sign up

Export Citation Format

Share Document