scholarly journals Research and Application of Air Source Heat Pump Technology at Rd. 60-10 Oil Delivery Site

2020 ◽  
Vol 218 ◽  
pp. 01005
Author(s):  
Shiyao He ◽  
Yuxi Ji ◽  
Wenhong Feng ◽  
Liling Wang ◽  
Tao Yang ◽  
...  

The heating methods currently used at oil delivery sites and transfer stations on North China Oilfield include electric bar heating, fuel oil heating, gas heating, etc. The traditional heating methods have adverse effect on energy conservation and environmental protection. They have low energy efficiency of heating and produces great pollution to the environment. The air source heat pump technology uses the heat in the air as the low-temperature heat source and transforms it to the high-temperature hot water, which will later serve as a heat tracing for crude oil gathering and transportation. No combustion effluent is produced in operation and the energy-saving effect is outstanding with high social-benefit.

2012 ◽  
Vol 482-484 ◽  
pp. 758-762
Author(s):  
Xing Wang Zhu ◽  
Chun Xia Hu ◽  
Yan Li Lv ◽  
Chao Xin Wang ◽  
Yu Gui Su

In this paper the system of air-source heat pump water heater(ASHPWH) using R134A to get 75°C hot water is proposed. The experiments on the performance of ASHPWH are conducted in two typical conditions, one for 7°C dry bulb temperature and 6°C wet bulb temperature, the other for 20°C dry bulb temperature and 15°C wet bulb temperature. In addition the variations of the suction temperature, the exhaust temperature, the suction pressure, the exhaust pressure, the transient heat capacity, the input power and COPs with the changing of the hot water tank temperature are analyzed. The results show that 75°C hot water can be produced steadily and the COPs are 2.84 and 3.68 respectively in two different conditions, therefore the ASHPWH has good energy saving effect.


2014 ◽  
Vol 587-589 ◽  
pp. 243-246
Author(s):  
Chu Ping Lu ◽  
Kai Ji

This paper is as an example of the hot water supply of the hotel in the city,The design of the hot water system is the solar energy and the air source heat pump,includes:the selection calculation of the air source heat pump of the water heater , the selection and calculation of the solar collector,the determination of the thermal storage tank and the determination of the circulating water pump of heat collecting .


2011 ◽  
Vol 383-390 ◽  
pp. 1933-1937
Author(s):  
Wei Xiu Shi ◽  
Wei Yi Li ◽  
Li Sheng Pan ◽  
Zhi Hua Zhou

Under the situation of energy crisis, air source heat pumps are paid more attention recently. In terms of energy saving, the feasibility and performance of boiled water machine with air source heat pump are studied by experiment in this paper. The results are as follows: the best outlet temperature of heat pump is 55°C in winter, and that is 65°C in other seasons correspondingly. Electromagnetic heater is used as the accessorial heating method, which can heat water to 95°C so as to be fit to drinking. Moreover, the energy saving effect of the unit is remarkable. At the end of the paper, the preliminary conception of structure and automatic control is proposed.


2012 ◽  
Vol 238 ◽  
pp. 478-481
Author(s):  
Zhen Qing Wang ◽  
Yan Chen ◽  
Hai Xia Wang

An air source heat pump system (ASHPS) was set up, which provided space heating and cooling, as well as hot water for an office building in Tianjin. Its operating performance in winter was evaluated based on test data. Considering the local abundant solar radiation and the way to provide energy in an office building, a simulation study was carried out on the combsystem of ASHP and flat plate air collector (FPAC). The effects of collector area and its outlet parameters on the heating performance of ASHP were studied, and the favorable operating and matching mode were recommended. The results indicate that ASHPS is a technically viable method in Tianjin in winter, but not economically, and the air-solar combsystem should be taken into account for its massive replacement for conventional energy.


2014 ◽  
Vol 541-542 ◽  
pp. 942-948
Author(s):  
Xian Peng Sun ◽  
Zhi Rong Zou ◽  
Yue Zhang

Based on the finite-time thermodynamic theory, an operation optimization, of water source heat pump in the combined solar with a dual heat source heat pump which is applied in a greenhouse heating system, is made. According to the ε-NTU method and entropy theory, heat exchange and balance equations are obtained. The function relationship between COP and the indoor temperature Tn, the ambient temperature Ta, low temperature heat source inlet temperature Tie and high temperature heat source inlet temperature Tic is also obtained. By means of programming, the impact of parameters on the COP and the way of regulating this water source heat pump system are presented in this article. The results show that: when a separate water source heat pump is running, by adjusting the hot water temperature and the match status of each indoor heating system, the energy-saving operation can be realized.


2015 ◽  
Vol 797 ◽  
pp. 185-191
Author(s):  
Arkadiusz Gużda ◽  
Norbert Szmolke

The article compares two means for domestic hot water production (DHW) for a detached house that is using gas boiler with a closed combustion chamber and air source heat pump water heater (ASHPWH). An analysis of domestic hot water production using an air source heat pump was made taking into account coefficient of performance listed according to the new BS EN 16147 standard. The analysis of outlay related to the investment and operating costs was also performed. Ultimately, the more profitable choice for domestic hot water production was made.


2014 ◽  
Vol 953-954 ◽  
pp. 136-143
Author(s):  
Jin Shun Wu ◽  
Yue Bo Hu ◽  
De Zhi Hu ◽  
Hong Wei Liu

In winter,Many families use air source heat pump because of the low evaporation temperature of the system, resulting in lower heating efficiency of system. To solve this problem, the low temperature solar assisted hot water was added to the project which is on the basis of air source heat pump, and the system has been tested. After analysis of the collection efficiency of solar collectors at low temperatures and comparative analysis of the temperature cycle, pressure, energy consumption of the low-temperature solar-assisted systems and air source heat pump system, the optimal collector temperature and law of heat pump refrigerant cycle changes of the system were obtained. Theoretically, comparative analysis of low temperature air source heat pumps and solar hot water secondary air source heat pump compression ratio and COP. It gives the key parameters affecting the compression ratio and COP, pointing out ways to improve the heat pump COP. Finally, a key measure to improve the thermal performance of the unit system is proposed, to provide a reference for future practical applications and research. Foreword Air source heat pump in ambient air contains rich low grade solar potential as a source of heat, it has inexhaustible characteristics [1] . The main reason for restricting the use of air source heat pump in northern area of our country is when the outdoor air temperature is low in winter, the outdoor coil frost severe heating efficiency air source heat pump is greatly reduced. Martinez suggested experimental study on the application of solar radiant floor heating systems , solar water temperature is 50-60°C, low efficiency, especially when overcast snow lower system efficiency [2] .In view of the outdoor coil frosting problem, direct expansion solar assisted heat pump water heater system using the proposed by Li Yuwu, from a certain extent alleviated the problem of heat in winter for coil winter fros, improving the heating coefficient and improved the operating characteristics of the unit. However, this system requires the direct absorption of heat in air tube, and the specific heat of air is small, difficult to heat storage, illumination by solar radiation impact, unstable system operation [3]. Based on the above issues, for the low-level office building , the new rural residential , this study presents low temperature solar auxiliary air source heat pump system , the device uses low-temperature solar hot water heat pump system as low , both full use of solar energy , but also eliminates the original system frost problems and improve the efficiency of solar collectors and heat set to improve the evaporation temperature of the evaporator , thereby increasing the compression ratio of the heat pump unit .


Sign in / Sign up

Export Citation Format

Share Document