scholarly journals On the assessment of a tunable auxiliary mass damper with a friction damper in its suspension: numerical study

2016 ◽  
Vol 83 ◽  
pp. 01005 ◽  
Author(s):  
E.L.C. Guerineau ◽  
H.T. Coelho ◽  
F.P. Lepore Neto ◽  
M.B. Santos ◽  
J. Mahfoud
2021 ◽  
Vol 242 ◽  
pp. 110129
Author(s):  
Meng-Chang Hsieh ◽  
Guan-Lee Huang ◽  
Haijun Liu ◽  
Shih-Jiun Chen ◽  
Bang-Fuh Chen

Structures ◽  
2022 ◽  
Vol 35 ◽  
pp. 968-989
Author(s):  
Ai Qi ◽  
Xuhong Liu ◽  
Rongjian Xu ◽  
Xueyuan Yan

Author(s):  
Masanori Imazeki ◽  
Koji Tanida ◽  
Masao Mutaguchi ◽  
Yuji Koike ◽  
Tamotsu Murata ◽  
...  

Abstract A hybrid mass damper system has been developed with a view to counteracting wind- and earthquake-excited vibrations of large high-rise building structures. In order to eliminate the large space needed to accommodate a pendulum-type mass damper adapted to the long period of high-rise building, mechanism has been devised for suspending the auxiliary mass on a V-shaped rail sliding on rollers. The base angle of the V-shaped rail is varied for adjusting the natural period of the mass damper system. A suboptimal algorithm based on the minimum norm method has been adopted for designing the auxiliary mass driving system. Three units of this damper system, each equipped with auxiliary mass weighing 110 tons, have been installed on a 52-story building. Satisfactory performance conforming in all practical aspects with design has been verified from vibration test on actual building after installation. As sequel, the functioning of the system during the first year of service is also reported.


2019 ◽  
Vol 452 ◽  
pp. 97-111 ◽  
Author(s):  
Weixing Shi ◽  
Liangkun Wang ◽  
Zheng Lu ◽  
Hongtao Wang

2019 ◽  
Vol 81 (6) ◽  
Author(s):  
Afham Zulhusmi Ahmad ◽  
Aminudin Abu ◽  
Lee Kee Quen ◽  
Nor A’zizi Othman ◽  
Faridah Che In

The Tuned Mass Damper (TMD) is generally as a passive vibration control device consisting of added auxiliary mass with functioning spring and damping elements. TMD is basically designed to be tuned to the dominant frequency of a structure which the excitation of frequency will resonate the structural motion out of phase to reduce unwanted vibration. However, a single unit TMD is only capable of suppressing the fundamental structural mode. In order to control multimode vibrations and to cater wide band seismic frequency, more than one TMD is required to improve the effectiveness of a control mechanism. For the purpose of this study, a 3-storey benchmark reinforced structural building subjected to El Centro seismic ground motion is modelled as uncontrolled Primary Structure (PS) by considering appropriate structural properties such as stiffness and damping. Mathematical modelling of uncontrolled PS is developed and further evaluated numerically by assuming the PS as an equivalent lumped system. For the case of controlled PS which the passive mechanism is included to the system, optimum parameters of both TMD and Multiple TMD (MTMD) are designed to be tuned to the dedicated structural modes where the performance is dependent on specified parameters such as auxiliary mass ratio, optimum damping ratio, and optimum frequency ratio. The eigen value analysis is carried out by assuming that the structure is a linear time-invariant system. The input and output components of structural system arrangements are then characterized in the transfer function manner and then converted into state space function. To enhance structural control effectiveness, the adaptive system is incorporated by the attachment of Magneto-Rheological (MR) damper to both single TMD and MTMD passive system. The response analysis of the control system arrangements is executed using both time history and frequency response analysis. The main objectives of the design are to minimize both structural peak and Root Mean Square (RMS) displacements. From the analysis, the designed control mechanisms are concluded as highly effective in reducing all structural floor displacements for the semi-active cases with 99% displacement reduction for the third and second floors, and 98% for the first floor, compared to the uncontrolled case. It is concluded that the MR damper significantly contributed to the enhancement of the passive system to mitigate structural seismic vibration.


2022 ◽  
pp. 136943322110509
Author(s):  
Xuan Zhang ◽  
Qiang Han ◽  
Kaiming Bi ◽  
Xiuli Du

Multiple vibration modes of an engineering structure might be excited by earthquake ground motions. Multiple tuned mass dampers (MTMDs) are widely used to control these multi-mode vibrations. However, in the commonly used MTMD system, the mass element in each tuned mass damper (TMD) is normally assumed to be the same. To improve the performance of MTMDs for seismic-induced vibration control, non-uniform MTMD masses are adopted in the present study to improve the mass utilization of TMD, and a location factor is proposed to determine the best location of each TMD in the MTMD system. The effectiveness of the proposed method is validated through numerical study. The results show that the proposed method effectively reduces the seismic responses of the structure induced by multiple vibration modes.


2021 ◽  
Vol 230 ◽  
pp. 111701
Author(s):  
Jianyang Xue ◽  
Chenwei Wu ◽  
Xicheng Zhang ◽  
Zhendong Qi

Sign in / Sign up

Export Citation Format

Share Document