Signifikante Differenzierung von Mammaläsionen durch den Einsatz der Strain ratio

Author(s):  
A Thomas ◽  
T Slowinski ◽  
T Fischer
Keyword(s):  
2018 ◽  
Author(s):  
D Vasile Balaban ◽  
C Marina ◽  
A Zoican ◽  
G Robu ◽  
I Enache ◽  
...  

Alloy Digest ◽  
1997 ◽  
Vol 46 (9) ◽  

Abstract Sandvik Ti-3Al-2.5V Grade 9 titanium-aluminum alloy offers excellent corrosion resistance, especially to chloride media, and has a high strength-to-weight ratio, which is especially suitable for use in aerospace applications. Tubing can be produced having a CSR (contractile strain ratio) that enhances the fatigue endurance limit. This datasheet provides information on composition, physical properties, elasticity, tensile properties, and bend strength as well as fatigue. It also includes information on corrosion resistance as well as forming, machining, and joining. Filing Code: TI-109. Producer or source: Sandvik.


2020 ◽  
Vol 08 (11) ◽  
pp. E1623-E1632
Author(s):  
Carlos Robles-Medranda ◽  
Roberto Oleas ◽  
Miguel Puga-Tejada ◽  
Manuel Valero ◽  
Raquel Del Valle ◽  
...  

Abstract Background and study aims Assessment of endoscopic ultrasonography (EUS)-elastography of the liver and spleen may identify patients with portal hypertension secondary to chronic liver disease. We aimed to evaluate use of EUS-elastography of the liver and spleen in identification of portal hypertension in patients with chronic liver disease. Patients and methods This was a single-center, diagnostic cohort study. Consecutive patients with liver cirrhosis and portal hypertension underwent EUS-elastography of the liver and spleen. Patients without a history of liver disease were enrolled as controls. The primary outcome was diagnostic yield of liver and spleen stiffness measurement via EUS-elastography in prediction of portal hypertension secondary to chronic liver cirrhosis. Cutoff values were defined through Youden’s index. Overall accuracy was calculated for parameters with an area under the receiver operating characteristic (AUROC) curve ≥ 80 %. Results Among the 61 patients included, 32 had cirrhosis of the liver. Liver and spleen stiffness was measured by the strain ratio and strain histogram, with sensitivity/(1 − specificity) AUROC values ≥ 80 %. For identification of patients with cirrhosis and portal hypertension, the liver strain ratio (SR) had a sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of 84.3 %, 82.8 %, 84.4 %, and 82.8 %, respectively; the liver strain histogram (SH) had values of 87.5 %, 69.0 %, 75.7 %, and 83.3 %, respectively. EUS elastography of the spleen via the SR reached a sensitivity, specificity, PPV, and NPV of 87.5 %, 69.0 %, 75.7 %, and 83.3 %, respectively, whereas the values of SH were 56.3 %, 89.7 %, 85.7 %, and 65.0 %, respectively. Conclusion Endoscopic ultrasonographic elastography of the liver and spleen is useful for diagnosis of portal hypertension in patients with cirrhosis.


2020 ◽  
Vol 0 (0) ◽  
Author(s):  
Marlit Karen Strobel ◽  
Maria Eveslage ◽  
Helen Ann Köster ◽  
Mareike Möllers ◽  
Janina Braun ◽  
...  

AbstractObjectivesThe aim of this study was to introduce cervical strain elastography to objectively assess the cervical tissue transformation process during induction of labour (IOL) and to evaluate the potential of cervical elastography as a predictor of successful IOL.MethodsA total of 41 patients with full-term pregnancies elected for an IOL were included. Vaginal ultrasound with measurement of cervical length and elastography and assessment of the Bishop Score were performed before and 3 h after IOL. The measured parameters were correlated to the outcome of IOL and the time until delivery.ResultsWe observed an association between the strain pattern and the value of the strain ratio 3 h after IOL and a successful IOL (p=0.0343 and p=0.0342, respectively) which can be well demonstrated by the results after 48 h. In our study population the cervical length and the Bishop Score did not prove to be relevant parameters for the prediction of a successful IOL.ConclusionsWe demonstrated for the first time that the cervical elastography pattern after the first prostaglandine application can help predict the outcome of IOL.


Author(s):  
Ilaria Celletti ◽  
Daniele Fresilli ◽  
Corrado De Vito ◽  
Marco Bononi ◽  
Sara Cardaccio ◽  
...  

Abstract Purpose To assess Strain Ratio (SRE) and Shear Wave Elastography (SWE) accuracy alone and with TIRADS classification, for the risk stratification of indeterminate thyroid nodules. Materials and methods 128 Patients with 128 indeterminate nodules candidates for thyroidectomy underwent preoperative staging neck ultrasound and were classified according to K-TIRADS score. After TIRADS evaluation, semi-quantitative (SRE) and quantitative (SWE expressed in kPa) elastosonography were performed and relative diagnostic performances, alone and in combination, were compared through ROC curves analysis. In order to maximize the SRE and SWE sensitivity and specificity, their cut-off values were calculated using the Liu test. Bonferroni test was used to evaluate statistically significant differences with a p value < 0.05. Results Sensitivity, specificity, PPV and NPV were, respectively, 71.4%, 82.4%, 62.5%, 87.5% for K-TIRADS baseline US, 85.7%, 94.1%, 85.7%, 94.1% for SRE and 57.1%, 79.4%, 53.3%, 81.8% for SWE (kPa expressed). SRE evaluation showed the best diagnostic accuracy compared to the SWE (kPa expressed) (p < 0.05) and to the K-TIRADS (p > 0.05). The association of SRE with conventional ultrasound with K-TIRADS score increased sensitivity (92.9% vs 71.4%) but decreased the specificity than conventional US alone (76.5% vs 82.4%). Conclusion Strain Elastosonography can be associated with K-TIRADS US examination in the thyroid nodule characterization with indeterminate cytology; in fact, adding the SRE to K-TIRADS assessment significantly increases its sensitivity and negative predictive value. However, further multicenter studies on larger population are warranted.


2021 ◽  
Vol 22 (Supplement_1) ◽  
Author(s):  
V Kaur ◽  
A Manouras ◽  
A Venkateshvaran

Abstract Funding Acknowledgements Type of funding sources: None. Background. Symptomatic rheumatic mitral stenosis (MS) results in elevation in left atrial (LA) pressure that is passively transmitted to derange pulmonary hemodynamics and subsequently elevate right ventricular afterload. We studied associations between LA to right atrial reservoir strain ratio (LA-RAs) and invasive pulmonary hemodynamics in addition to the ratio’s ability to identify subjects with elevated pulmonary vascular resistance (PVR). Methods.  Consecutive MS subjects undergoing right heart catheterization (RHC) and percutaneous transvenous mitral commissurotomy (PTMC) were enrolled. Subjects with atrial fibrillation, &gt;mild mitral regurgitation, concomitant aortic valve or ischemic heart disease were excluded. LA-RAs was assessed by speckle-tracking echocardiography and stratified into high or low LA-RAs subgroups based on mean value. Correlations with invasive pulmonary hemodynamics was studied. ROC analysis was performed to identify pulmonary hypertension (PH) and PVR &gt; 3 Wood Units. Results. 110 subjects were analysed (age: 32 ± 8; 72% female). LA and RA reservoir strain was feasible in 88 (80%) and 83 (75%) subjects respectively. Patients with low LA-RAs demonstrated more severe MS (0.8 ± 0.1 vs. 1.0 ± 0.2cm2), higher mean pulmonary artery (43 ± 13 vs. 33 ± 13mmHg) and capillary wedge pressure (28 ± 6 vs.23 ± 16mmHg) as compared with high LA-RAs (p &lt; 0.001 for all). LA-RAs was associated with invasive PA systolic (r=-0.30;p = 0.05), diastolic (r=-0.28;p = 0.02) and mean (r=-0.33; p = 0.002) pressures, demonstrated modest ability to identify elevated PVR (AUC = 0.65;p = 0.03) and strong ability to identify PH (AUC = 0.75; p &lt; 0.001). LA-RAs significantly increased after PTMC (0.43 ± 0.1 to 0.52 ± 0.1;p &lt; 0.001). Conclusions. The novel atrial strain ratio is associated with measures of invasive pulmonary hemodynamics and demonstrates ability to identify PH and elevated PVR in MS.


2012 ◽  
Vol 81 (2) ◽  
pp. 286-291 ◽  
Author(s):  
Chun-Ping Ning ◽  
Shuang-Quan Jiang ◽  
Tao Zhang ◽  
Li-tao Sun ◽  
Yu-Jie Liu ◽  
...  

2011 ◽  
Vol 295-297 ◽  
pp. 2227-2230
Author(s):  
Cong Ling Zhou

In this study, fatigue tests have been performed using two kinds of specimens made of 25 steel. One is pre-strained specimen with pre-strain ratio changing from 2% to 8% by tension, the other is roller worked with deformation of 0.5 mm and 1.0 mm in diameter direction. In the case of pre-strained specimen, the fatigue limit increases according to increase of tensile pre-strain, the fatigue limit of 8% pre-strained specimen is 25% higher than that of non-pre-strained one; in the case of roller worked specimen, the fatigue limit of R05 and R10 is 126% and 143% to that of non-roller worked specimen, respectively. These remarkable improvements of fatigue limit would be caused by the existence of compressive residual stress, work-hardening and the elongated microscopic structures.


1960 ◽  
Vol 26 (170) ◽  
pp. 1327-1332
Author(s):  
Fujio NAKANISHI ◽  
Yasuo SATO

Sign in / Sign up

Export Citation Format

Share Document