scholarly journals TIRADS, SRE and SWE in INDETERMINATE thyroid nodule characterization: Which has better diagnostic performance?

Author(s):  
Ilaria Celletti ◽  
Daniele Fresilli ◽  
Corrado De Vito ◽  
Marco Bononi ◽  
Sara Cardaccio ◽  
...  

Abstract Purpose To assess Strain Ratio (SRE) and Shear Wave Elastography (SWE) accuracy alone and with TIRADS classification, for the risk stratification of indeterminate thyroid nodules. Materials and methods 128 Patients with 128 indeterminate nodules candidates for thyroidectomy underwent preoperative staging neck ultrasound and were classified according to K-TIRADS score. After TIRADS evaluation, semi-quantitative (SRE) and quantitative (SWE expressed in kPa) elastosonography were performed and relative diagnostic performances, alone and in combination, were compared through ROC curves analysis. In order to maximize the SRE and SWE sensitivity and specificity, their cut-off values were calculated using the Liu test. Bonferroni test was used to evaluate statistically significant differences with a p value < 0.05. Results Sensitivity, specificity, PPV and NPV were, respectively, 71.4%, 82.4%, 62.5%, 87.5% for K-TIRADS baseline US, 85.7%, 94.1%, 85.7%, 94.1% for SRE and 57.1%, 79.4%, 53.3%, 81.8% for SWE (kPa expressed). SRE evaluation showed the best diagnostic accuracy compared to the SWE (kPa expressed) (p < 0.05) and to the K-TIRADS (p > 0.05). The association of SRE with conventional ultrasound with K-TIRADS score increased sensitivity (92.9% vs 71.4%) but decreased the specificity than conventional US alone (76.5% vs 82.4%). Conclusion Strain Elastosonography can be associated with K-TIRADS US examination in the thyroid nodule characterization with indeterminate cytology; in fact, adding the SRE to K-TIRADS assessment significantly increases its sensitivity and negative predictive value. However, further multicenter studies on larger population are warranted.

2019 ◽  
Vol 40 (04) ◽  
pp. 495-503 ◽  
Author(s):  
Vito Cantisani ◽  
Emanuele David ◽  
Hektor Grazhdani ◽  
Antonello Rubini ◽  
Maija Radzina ◽  
...  

Abstract Purpose To evaluate the diagnostic performance of strain ratio elastography (SRE) and shear wave elastography (SWE) alone and in combination with Thyroid Imaging Reporting and Data System (TIRADS) classification parameters to improve differentiation between benign and malignant thyroid nodules. Materials and Methods In this prospective study benign (n = 191) and malignant (n = 52) thyroid nodules were examined with high-resolution ultrasound (US) features using the TIRADS lexicon and SRE semiquantitative and SWE quantitative findings using histology or cytology as the gold standard with a 12-month follow-up. Sensitivity (Se), specificity (Sp) and the area under the ROC curve (AUROC) were used to evaluate the diagnostic performance of each feature and combinations of the methods. Results TIRADS score showed a sensitivity of 59.6 %, a specificity of 83.8 % with an AUROC of 0.717, a PPV of 50.0 % and an NPV of 88.4 %. SRE yielded the highest performance with a sensitivity of 82.7 %, a specificity of 92.7 % with AUROC of 0.877, a PPV 75.4 % and an NPV of 95.2 %. SWE (kPa) had a sensitivity and specificity of 67.3 % and 82.7 %, respectively, with an AUROC of 0.750, a PPV of 51.5 % and an NPV of 90.3 %. Differences were significant for SRE only but not for SWE. Conclusion Ultrasound elastography may improve thyroid nodule discrimination. In particular, SRE has a better performance than TIRADS classification, while their combination improves sensitivity.


2019 ◽  
Vol 9 (2) ◽  
pp. 334-338
Author(s):  
Qing Yang ◽  
Wenhong Zhou ◽  
Jiyu Li ◽  
Guojun Wu ◽  
Feng Ding ◽  
...  

Objective: To compare the diagnostic value of shear wave elastography (SWE) and real-time elastography (RTE) in the diagnosis of benign and malignant thyroid nodules. Methods: A total of 34 patients who ever received thyroidectomy in our hospital from January 2016 to January 2018 were identified. Meanwhile, all the patients received SWE and RTE before surgery, and all the diagnoses were confirmed by pathological examinations. With respect to SWE technique, the Subject Operating Characteristics (ROC) curves were drawn, in order to obtain the optimal threshold and then make differential diagnoses of benign and malignant thyroid nodules. In terms of RTE, the Rago 5 scoring method was utilized to make differential diagnoses of benign and malignant thyroid nodules. Besides, the pathological examinations after surgery could be considered as the golden standard. At last, the sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of SWE and RTE were calculated, respectively. Results: A total of 51 thyroid nodules were identified, and 41 nodules were benign, 10 nodules were malignant. On the basis of ROC curves, with respect to SWE, the best threshold for differential diagnosis of benign and malignant thyroid nodules is 38.3 kPa. The sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of SWE were 72.7% (8/11), 85% (34/40), 82.4% (42/51), 68.4% (13/19), and 87.5% (35/40), respectively. And the diagnostic indicators of RTE were 81.8% (9/11), 87.5% (35/40), 84.3% (43/51), 73.7% (14/19), and 90.0% (36/40). The sensitivity of quasi-static elastography in differential diagnosis of benign and malignant thyroid nodules with diameter ≤1 cm was 87.5% (7/8), and the sensitivity of SWE was 50.0% (5/10). In addition, the accuracy of SWE in differential diagnosis of benign and malignant thyroid nodules with diameter ≥3 cm was 100% (6/6), and the accuracy of RTE for this kind of thyroid nodules was 66.7% (4/6). Conclusion: Both SWE and RTE technology have good application value in differential diagnosis of benign and malignant thyroid nodules. But, SWE is preferable when making diagnosis of benign and malignant thyroid nodules with diameter ≥3 cm, and RTE was superior in detecting benign and malignant thyroid nodules with diameter ≤1 cm.


2019 ◽  
Author(s):  
Hairu Li ◽  
Yulan Peng ◽  
Yan Wang ◽  
Hong Ai ◽  
Xiaodong Zhou ◽  
...  

Abstract Background: Accurate diagnosis of high-risk nodules of 2015 American thyroid association(ATA) would reduce invasive testing. Elastography is useful for identifying benign and malignant thyroid nodules. Aims: To investigate the diagnostic efficiency of elastography for high-suspicion thyroid nodules based on the 2015 guidelines in the Chinese population. Materials and Methods: A total of 1445 thyroid nodules were subjected to conventional ultrasound and strain elastography examinations. Receiver operating characteristic(ROC) curves were plotted to evaluate the diagnostic performance of elasticity score(ES) and strain ratio(SR). Logistic regression analysis was used to determine the predictors of malignancy. Results: The areas under the curve of ES and SR were 0.828 and 0.732. The sensitivity, specificity, accuracy, positive predictive value(PPV) and negative predictive value(NPV) of ES were 92.4%, 60.7%, 79.0%, 76.3% and 85.5% , and those of the SR were 81.1%, 50.1%, 68.9%, 65.9% and 67.9%. Logistic regression analysis showed that microcalcification (OR=5.290), taller than wide (OR=12.710), irregular margin (OR=10.117), extrathyroidal extension (OR=6.412), ES (OR=3.741) and SR (OR=1.083) were independent predictors of malignant thyroid nodules. Sensitivity, specificity, accuracy, PPV and NPV of ES were all superior in nodules ≥1 cm than in those <1 cm (95.0% vs 90.4%, 68.8% vs 56.8%, 85.9% vs 74.4%, 85.2% vs 69.9%, 87.8% vs 84.2%, respectively). Conclusions: Elastography with ES is valuable for assessment of high-suspicion thyroid nodules based on the 2015 ATA guidelines, especially in nodules ≥1 cm.


Author(s):  
Vito Cantisani ◽  
Emanuele David ◽  
Richard G. Barr ◽  
Maija Radzina ◽  
Valeria de Soccio ◽  
...  

Abstract Purpose To evaluate the diagnostic performance of strain elastography (SE) and 2 D shear wave elastography (SWE) and SE/SWE combination in comparison with conventional multiparametric ultrasound (US) with respect to improving BI-RADS classification results and differentiating benign and malignant breast lesions using a qualitative and quantitative assessment. Materials and Methods In this prospective study, 130 histologically proven breast masses were evaluated with baseline US, color Doppler ultrasound (CDUS), SE and SWE (Toshiba Aplio 500 with a 7–15 MHz wide-band linear transducer). Each lesion was classified according to the BIRADS lexicon by evaluating the size, the B-mode and color Doppler features, the SE qualitative (point color scale) and SE semi-quantitative (strain ratio) methods, and quantitative SWE. Histological results were compared with BIRADS, strain ratio (SR) and shear wave elastography (SWE) all performed by one investigator blinded to the clinical examination and mammographic results at the time of the US examination. The area under the ROC curve (AUC) was calculated to evaluate the diagnostic performance of B-mode US, SE, SWE, and their combination. Results Histological examination revealed 47 benign and 83 malignant breast lesions. The accuracy of SR was statistically significantly higher than SWE (sensitivity, specificity and AUC were 89.2 %, 76.6 % and 0.83 for SR and 72.3 %, 66.0 % and 0.69 for SWE, respectively, p = 0.003) but not higher than B-mode US (B-mode US sensitivity, specificity and AUC were 85.5 %, 78.8 %, 0.821, respectively, p = 1.000). Conclusion Our experience suggests that conventional US in combination with both SE and SWE is a valid tool that can be useful in the clinical setting, can improve BIRADS category assessment and may help in the differentiation of benign from malignant breast lesions, with SE having higher accuracy than SWE.


2020 ◽  
Vol 76 (3) ◽  
pp. 381-390 ◽  
Author(s):  
Wei-Bing Zhang ◽  
Jing-Jing Li ◽  
Xiang-Yong Chen ◽  
Bei-Li He ◽  
Rong-Hua Shen ◽  
...  

OBJECTIVES: To compare the diagnostic efficacy of shear wave elastography (SWE) comnined with ACR TI-RADS categories for malignancy risk stratification of thyroid nodules with interminate FNA cytology. METHODS: The clinical data, sonographic features, ACR TI-RADS grading and shear wave elastography images of 193 patients of surgical pathologically proven thyroid nodules with interminate FNA cytology were retrospectively analyzed. The diagnostic efficacy of ACR TI-RADS categories, the maximum Young’s modulus (Emax) of SWE and the combination of the two were calculated respectively. RESULTS: The ROC curves were drawn using surgical pathology results as the gold standard. The ROC curves indicated that the cut-off value of ACR TI-RADS and Emax of SWE was TR5 and 41.2 kPa respectively, and the area under the ROC curve (AUC) was 0.864 (95% CI: 0.879–0.934) and 0.858 (95% CI: 0.796–0.920) respectively. The diagnostic sensitivity, specificity and accuracy of ACR TI-RADS was 81.4% (127/156), 84.8% (31/37), and 81.9% (158/193), respectively. That of SWE Emax was 80.8% (126/156), 78.4% (29/37), and 80.3% (155/193), respectively. After SWE combined with ACR TI-RADS, the sensitivity, specificity and accuracy was 94.2% (147/156), 75.7% (28/37), and 90.7% (175/193), respectively. CONCLUSIONS: ACR TI-RADS classification system and shear wave elastography had high diagnostic efficacy for thyroid nodules with interminate FNA cytology. The combination of the two could improve diagnostic sensitivity and accuracy, and could help to differentiate benign and malignant thyroid nodules with interminate FNA cytology.


2020 ◽  
Vol 08 (11) ◽  
pp. E1623-E1632
Author(s):  
Carlos Robles-Medranda ◽  
Roberto Oleas ◽  
Miguel Puga-Tejada ◽  
Manuel Valero ◽  
Raquel Del Valle ◽  
...  

Abstract Background and study aims Assessment of endoscopic ultrasonography (EUS)-elastography of the liver and spleen may identify patients with portal hypertension secondary to chronic liver disease. We aimed to evaluate use of EUS-elastography of the liver and spleen in identification of portal hypertension in patients with chronic liver disease. Patients and methods This was a single-center, diagnostic cohort study. Consecutive patients with liver cirrhosis and portal hypertension underwent EUS-elastography of the liver and spleen. Patients without a history of liver disease were enrolled as controls. The primary outcome was diagnostic yield of liver and spleen stiffness measurement via EUS-elastography in prediction of portal hypertension secondary to chronic liver cirrhosis. Cutoff values were defined through Youden’s index. Overall accuracy was calculated for parameters with an area under the receiver operating characteristic (AUROC) curve ≥ 80 %. Results Among the 61 patients included, 32 had cirrhosis of the liver. Liver and spleen stiffness was measured by the strain ratio and strain histogram, with sensitivity/(1 − specificity) AUROC values ≥ 80 %. For identification of patients with cirrhosis and portal hypertension, the liver strain ratio (SR) had a sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of 84.3 %, 82.8 %, 84.4 %, and 82.8 %, respectively; the liver strain histogram (SH) had values of 87.5 %, 69.0 %, 75.7 %, and 83.3 %, respectively. EUS elastography of the spleen via the SR reached a sensitivity, specificity, PPV, and NPV of 87.5 %, 69.0 %, 75.7 %, and 83.3 %, respectively, whereas the values of SH were 56.3 %, 89.7 %, 85.7 %, and 65.0 %, respectively. Conclusion Endoscopic ultrasonographic elastography of the liver and spleen is useful for diagnosis of portal hypertension in patients with cirrhosis.


Author(s):  
Anna Lentzsch ◽  
Laura Schöllhorn ◽  
Christel Schnorr ◽  
Robert Siggel ◽  
Sandra Liakopoulos

Abstract Purpose To compare swept-source (SS) versus spectral-domain (SD) optical coherence tomography angiography (OCTA) for the detection of macular neovascularization (MNV). Methods In this prospective cohort study, 72 eyes of 54 patients with subretinal hyperreflective material (SHRM) and/or pigment epithelial detachment (PED) on OCT possibly corresponding to MNV in at least one eye were included. OCTA scans were acquired using two devices, the PLEX Elite 9000 SS-OCTA and the Spectralis SD-OCTA. Fluorescein angiography (FA) was used as reference. Two graders independently evaluated en face OCTA images using a preset slab as well as a manually modified slab, followed by a combination of en face and cross-sectional OCTA. Results Sensitivity (specificity) for the automated slabs was 51.7% (93.0%) for SS-OCTA versus 58.6% (95.3%) for SD-OCTA. Manual modification of segmentation increased sensitivity to 79.3% for SS-OCTA but not for SD-OCTA (58.6%). The combination of en face OCTA with cross-sectional OCTA reached highest sensitivity values (SS-OCTA: 82.8%, SD-OCTA: 86.2%), and lowest number of cases with discrepancies between SS-OCTA and SD-OCTA (4.2%). Fleiss kappa as measure of concordance between FA, SS-OCTA, and SD-OCTA was 0.56 for the automated slabs, 0.60 for the manual slabs, and 0.73 (good agreement) for the combination of en face OCTA with cross-sectional OCTA. Concordance to FA was moderate for the automated slabs and good for manual slabs and combination with cross-sectional OCTA of both devices. Conclusion Both devices reached comparable results regarding the detection of MNV on OCTA. Sensitivity for MNV detection and agreement between devices was best when evaluating a combination of en face and cross-sectional OCTA.


Children ◽  
2021 ◽  
Vol 8 (6) ◽  
pp. 521
Author(s):  
Ina Nehring ◽  
Heribert Sattel ◽  
Maesa Al-Hallak ◽  
Martin Sack ◽  
Peter Henningsen ◽  
...  

Thousands of refugees who have entered Europe experienced threatening conditions, potentially leading to post traumatic stress disorder (PTSD), which has to be detected and treated early to avoid chronic manifestation, especially in children. We aimed to evaluate and test suitable screening tools to detect PTSD in children. Syrian refugee children aged 4–14 years were examined using the PTSD-semi-structured interview, the Kinder-DIPS, and the Child Behavior Checklist (CBCL). The latter was evaluated as a potential screening tool for PTSD using (i) the CBCL-PTSD subscale and (ii) an alternative subscale consisting of a psychometrically guided selection of items with an appropriate correlation to PTSD and a sufficient prevalence (presence in more than 20% of the cases with PTSD). For both tools we calculated sensitivity, specificity, and a receiver operating characteristic (ROC) curve. Depending on the sum score of the items, the 20-item CBCL-PTSD subscale as used in previous studies yielded a maximal sensitivity of 85% and specificity of 76%. The psychometrically guided item selection resulted in a sensitivity of 85% and a specificity of 83%. The areas under the ROC curves were the same for both tools (0.9). Both subscales may be suitable as screening instrument for PTSD in refugee children, as they reveal a high sensitivity and specificity.


2021 ◽  
Vol 22 (1) ◽  
Author(s):  
Ning An ◽  
Ji Sheng Lin ◽  
Qi Fei

Abstract Background To compare the validation of four tools for identifying painful new osteoporotic vertebral compression fractures (PNOVCFs) in older Chinese men: bone mineral density (BMD), Asian osteoporosis self-assessment tool (OSTA), World Health Organization fracture risk assessment tool (FRAX) (without BMD) and Beijing Friendship Hospital Osteoporosis Self-Assessment Tool (BFH-OSTM). Methods A cross sectional study was conducted from 2013 to 2019. A total of 846 men aged ≥50 were included and were divided into two groups: Fracture Group (patients with PNOVCFs underwent percutaneous vertebroplasty surgery) and Non-Fracture Group (community dwelled subjects for healthy examination). All subjects accepted a dual-energy X-ray BMD test and a structured questionnaire. The results of BMD, OSTA, FRAX and BFH-OSTM scores were assessed and receiver-operating characteristic (ROC) curves were generated to compare the validity of four tools for identifying PNOVCFs. Optimal cutoff points, sensitivity, specificity, and areas under the ROC curves (AUCs) were determined. Results There were significant differences including BMD T score (femoral neck, total hip and L1-L4), OSTA, FRAX and BFH-OSTM scores between Fracture group and Non-fracture group. Compared to BMD and OSTA, BFH-OSTM and FRAX had better predictive value, the sensitivity, specificity and AUC value are 0.841, 81.29%, 70.67% and 0.796, 74.85%, 78.52%, respectively. Compared with FRAX, the BFH-OSTM has a better AUC value. Conclusions Both BFH-OSTM and FRAX can be used to identify POVCFs, However, BFH-OSTM model may be a more simple and effective tool to identify the risk of POVCFs in Chinese elderly men.