An International Standard for Low Molecular Weight Heparin

1988 ◽  
Vol 60 (01) ◽  
pp. 001-007 ◽  
Author(s):  
T W Barrowcliffe ◽  
A D Curtis ◽  
E A Johnson ◽  
D P Thomas

SummaryAn international collaborative study has been carried out with the aim of establishing an international standard for low molecular weight (LMW) heparin. Three preparations of LMW heparin were assayed against the International Standard for unfractionated heparin (UFH) by 25 laboratories in 13 countries, using nine different assay methods. The results confirmed previous findings of non-parallel assays, wide interlaboratory variability and differences between methods when LMW heparins are assayed against a UFH standard. Use of one of the LMW heparins as a standard for the other two gave parallel assays and much closer agreement between laboratories. The preparation in ampoules coded 85/600 was selected as likely to give the best agreement with the largest number of LMW heparins; potencies were assigned by taking the mean of all the anti-Xa assays, and the mean of the thrombin and APTT assays, to represent the two major groups of activities. Preparation 85/600 has been established by WHO as the 1st International Standard for LMW heparin, with potencies of 1,680 iu/ampoule by anti-Xa assays and 665 iu/ampoule by thrombin inhibition and APTT assays.

1984 ◽  
Vol 52 (02) ◽  
pp. 148-153 ◽  
Author(s):  
D P Thomas ◽  
A D Curtis ◽  
T W Barrowcliffe

SummaryAn international collaborative study, in which 22 laboratories participated, was carried out to establish a replacement for the International Standard for Heparin. A total of 248 assays were analyzed, including APTT, thrombin inhibition and anti-Xa assays, as well as pharmacopoeial assays. Overall, there was less than 5% difference in the mean potency estimates of the candidate preparations, by all assay methods. The freeze-dried preparation 82/502 demonstrated the closest parallelism by bioassay to the existing standard and was established by WHO as the 4th International Standard for Heparin, with an assigned unitage of 1780 i.u. per ampoule.


1985 ◽  
Vol 54 (03) ◽  
pp. 675-679 ◽  
Author(s):  
T W Barrowcliffe ◽  
A D Curtis ◽  
T P Tomlinson ◽  
A R Hubbard ◽  
E A Johnson ◽  
...  

SummaryA collaborative study was carried out, in which eight laboratories each assayed eight low molecular weight (LMW) heparins against the International Standard (IS) for heparin. APTT assays and three types of anti-Xa method were used. The results of this study showed that:1. LMW heparins cannot be validly assayed against the IS by APTT or anti-Xa methods.2. Potencies of LMW heparins vs. the IS differed considerably between the four types of assay method used and also between different laboratories using the same type of method.3. Adoption of a single LMW heparin standard would improve validity, improve inter-laboratory variation, and largely abolish the differences between the three types of anti-Xa method. However, since calibration of a LMW heparin standard against the IS would give potencies that differ widely by the different assay methods, a single assay method such as the anti-Xa amidolytic, plasma, would need to be chosen for this calibration.


1987 ◽  
Vol 58 (03) ◽  
pp. 879-883 ◽  
Author(s):  
P Sié ◽  
M F Aillaud ◽  
D de Prost ◽  
C Droullé ◽  
F Forestier ◽  
...  

SummaryThe only sensitive and convenient assay to assess the biological activity of low molecular weight heparins (LMWHs) is based on the potentiation of activated factor Xa inhibition. Several procedures for measuring the socalled anti Xa activity have been proposed. In this collaborative study including eight laboratories, we have used four different assays (three amidolytic and one clotting based methods) for measuring the anti Xa activity of ex vivo samples obtained after injecting three different LMWHs. The dispersion of the results obtained by calibration against standard heparin could be reduced by using any of the three LMWHs for calibration. A coefficient of variation less than 0.20 between values obtained in different laboratories using a variety of methods seems acceptable. However it is necessary to refer to a common international standard for expressing the results in units and to define, for each of the three products, the therapeutic range.


Author(s):  
Erdem Fadiloglu ◽  
Atakan Tanacan ◽  
Canan Unal ◽  
Mehmet Sinan Beksac

<p><strong>Objective:</strong> To evaluate the subsequent pregnancy outcomes of women who have experienced unexplained stillbirth in their previous gestations.</p><p><strong>Study Design:</strong> This retrospective cohort consisted of 14 pregnancies who had stillbirth (without known risk factors) in their previous pregnancies. These patients had been included in a special preconceptional care program to be evaluated in terms of etiological risk factors for stillbirth. At least one of the risk factors, such as methylenetetrahydrofolate reductase (MTHFR) polymorphisms, hereditary thrombophilias and autoimmune problems, were defined in this study population. After detection of pregnancy, the patients were administered low-dose low-molecular-weight heparin (LMWH) (enoxaparin, 1×2000 Anti-XA IU/0.2 mL/day), low-dose salicylic acid (100 mg/day) and low-dose corticosteroid (methylprednisolone, 1×4 mg/day orally) in necessary cases.</p><p><strong>Results:</strong> Out of 14 pregnancies, 4 (28.5%) ended up with miscarriages at 9, 11, 11 and 15 gestational weeks, respectively. The remaining 10 pregnancies ended up with alive deliveries. The mean gestational week at birth was 36.4±0.51, while the mean birthweight was 2882±381.01 g. Out of 10 pregnancies, only one was diagnosed as IUGR. Only two newborn necessitated hospitalization in the neonatal intensive care unit (NICU) due to respiratory problems. Both newborns were discharged from the NICU without any further complication at the post-partum 5th day. </p><p><strong>Conclusion:</strong> Patients with a prior stillbirth should be screened for MTHFR polymorphisms, autoimmune problems and hereditary thrombophilias, especially in case of absence of any etiological factor. Management of these patients with low-dose aspirin, low-dose low molecular weight heparin and corticosteroids seemed to be beneficial for increasing live birth rates and avoiding obstetric complications.</p>


Blood ◽  
2015 ◽  
Vol 126 (23) ◽  
pp. 746-746 ◽  
Author(s):  
Nathan T. Connell ◽  
Gregory A. Abel ◽  
Jean M. Connors

Introduction: Patients with active malignancy who develop venous thromboembolism (VTE) have historically been anticoagulated with a vitamin K antagonist (VKA) such as warfarin. The CLOT study (Lee et al., NEJM, 2003) demonstrated that injection with the low-molecular weight heparin (LMWH) dalteparin was better than warfarin at preventing recurrence of VTE in cancer patients, which changed clinical practice in the United States; however, a subsequent competing risks analysis (Parpia et al., Contemp Clin Trials, 2011) suggested the magnitude of this benefit may be less than previously believed. Neither patient-focused measures of utility nor the cost of each strategy have been evaluated in the current treatment era. We aimed to characterize the effectiveness and costs associated with these two management strategies for malignancy-associated VTE. Methods: We constructed a Markov state transition model to compare the cost-effectiveness of LMWH to VKA therapy for treatment of malignancy-associated thrombosis from a societal perspective. The model had 4 health states: initial anticoagulation, extended anticoagulation, no anticoagulation, and deceased. Cycle-length was 6 months with a lifetime horizon. Potential events in each cycle included recurrent VTE and death from recurrent VTE, major bleeding and death from major bleeding, minor bleeding, and death from other causes. Model inputs for event probabilities, costs, and utility were obtained from previously published literature (e.g., the ONCENOX, Main-LITE, CLOT, CANTHANOX, and CATCH trials); while no specific data exist for the utility of each strategy for treatment of malignancy-associated VTE, we assumed they would be similar to utilities previously published for non-malignant VTE, and performed sensitivity analysis to assess the robustness of our results. Microsimulation of 1000 trials was performed to calculate mean quality-adjusted life-years (QALYs) and costs associated with the two anticoagulation strategies. Results: Using a fixed effects model, the meta-analytic estimates of the odds ratio for major bleeding from LMWH as compared to VKA therapy was 0.99 (95% CI 0.65 - 1.50). The odds ratio for recurrent VTE while on LMWH as compared to VKA was 0.55 (95% CI 0.40 - 0.75) in favor of LMWH. The mean cost of the VKA strategy was $6,383.39 (±$5174.56) and for the LMWH strategy it was $64,975.83 (±$3,4743.63). The mean effectiveness of the VKA strategy was 1.19 QALYs (range 0.20 - 7.51); for the LMWH strategy it was 1.46 QALYs (range 0.20 - 9.03), resulting in a mean increase of 0.27 QALYs (Figure). The incremental cost-effectiveness ratio (ICER) was thus $221,281.83 per QALY. One-way sensitivity analysis evaluating the utility of the LMWH strategy from 0 - 1 revealed that VKA was always the preferred strategy at a willingness to pay (WTP) threshold of $100,000 per QALY. Conclusions: While LMWH is an effective treatment for malignancy-associated VTE, we found that it offers only a small gain in QALYs compared to VKAs, and that this gain is associated with a significant increase in cost. Our data suggest that LMWH is not a cost-effective strategy when applied to all patients with malignancy-associated VTE and that VKAs may be a reasonable alternative to LMWH. Figure 1. Figure 1. Disclosures No relevant conflicts of interest to declare.


Author(s):  
Cyntia Kornelius ◽  
Darwati Muhadi ◽  
Mansyur Arif

Heparin and Low molecular weight heparin (LMWH) had been used widely for prevention and treatment of thrombosis in the patients with acute coronary syndrome (ACS). Actually, the administration of heparin may caused some adverse effect, such as heparin inducedthrombocytopenia (HIT). This study was aimed to reveal thrombocytes count in patients with ACS who underwent LMWH therapy. An observational study with cohort prospective design was performed in 30 patients with ACS. The thrombocytes count was obtained from complete blood count (CBC) by using haematology analyzer (Sysmex XT 2000i) that performed at Clinical Pathology Laboratory, Dr. Wahidin Sudirohusodo Hospital, Makassar. The obtained data was analyzed with Wilcoxon test. The mean thrombocytes count before the administration of LMWH was 236.800/μL, while mean thrombocytes count after the administration of LMWH was 280.270/μL. Suprisingly this data showed that in general thrombocytes count was increased significantly (P=0.004) five day after starting LMWH therapy. In this study only one (3.3%) of 30 patients who received LMWH had trombocytes count less than 150.000/μL. Based on this study an antibody test to PF4-heparin complex was needed to determined occurance of HIT in this patient. The thrombocytes count was increased significantly (P=0.004) in patients with ACS who had given LMWH therapy.


1995 ◽  
Vol 74 (03) ◽  
pp. 893-899 ◽  
Author(s):  
E Gray ◽  
A B Heath ◽  
B Mulloy ◽  
J-M Spiese ◽  
T W Barrowcliffe

SummaryA European collaborative study, in which 16 laboratories participated, was carried out to assess the performance of the European Pharmacopoeia (EP) monograph methods for anticoagulant activities (anti-Xa and anti-IIa assays) of low molecular mass (EMM) heparin and to assess the suitability of six candidate materials as the EP working standard for LMM heparin. There was good interlaboratory agreement for both types of assays as indicated by most gcv’s being less than 10%, indicating acceptable performance of the EP assay methods. All the candidate preparations gave dose-response curves parallel to the 1st International Standard for Low Molecular Weight heparin and to each other. All preparations, possibly with the exception of E and F, gave similar performance as measured by interlaboratory agreement and would be suitable as working standards. Based on these data, preparations A, B, C and D have been established by the EP as official EP Biological Reference Preparations and they will be issued as successive batches.


Blood ◽  
2005 ◽  
Vol 106 (11) ◽  
pp. 4147-4147
Author(s):  
D. Hoppensteadt ◽  
W. Jeske ◽  
D. Fareed ◽  
F. Baltasar ◽  
J. M. Walenga ◽  
...  

Abstract Background: Because of the relative insensitivity of the global clot based assays such as the activated partial thromboplastin time (APTT), the low molecular weight heparins (LMWHs) are potency evaluated/optimized in the anti-Xa (AXa) and heptest. A new clot based assay namely, prothrombin induced clotting time (PiCT) is sensitive to the anticoagulant effects of LMWHs and related drugs. As the LMWHs are standardized using the anti-Xa methods, using the International Standards, this study was designed to cross validate the 2nd International Standard for LMWHs(NIBSC 01/608) in various assay methods. Methods: Commercially available LMWHs, Dalteparin (D), Enoxaparin (E), Tinzaparin (T) and the 1st International Standard (85/600) were crossed referenced against the 2nd International Standard (NIBSC 01/608) using an amidolytic AXa method. Each of these LMWHs were compared in the AXa, adjusted concentration range of 0–1.0 U/ml using the Heptest, AXa, AIIa and PiCT. In addition plasma samples from patients receiving a LMWH, E for therapeutic and interventional purposes were measured using various tests. Results: The AXa potency adjusted LMWHs (D, E, and T) and 1st International Standard provided superimposable concentration curves in the amidolytic AXa assays. However marked differences in the heptest and PiCT were noted. Major differences were noted in the AIIA levels, even between the two International standards. When patients samples (n=75) from a therapeutic trial (1.0 mg/kg BID/SC) were evaluated, assay based differences were further amplified. The amidolytic AXa assay consistently measured higher AXa levels. When the two standards were cross-referenced with one another in different assays, major differences were noted in the clot-based assays. Even in the AXa assay at equivalent AXa levels, differences were obvious. Conclusions: These results suggest that both of the International Standards of LMWH are valid for only the cross standardization of the AXa activities of LMWHs. If any of the other methods were used, significantly different results were obtained with each of the individual LMWHs. Thus, the 2nd International Standard should only be used for amidolytic AXa assay for potency referencing purposes. Moreover, the stated potency of the 2nd Internation Standard may need to be readjusted against the 1st Standard to obtain valid results. These standards are of limited value in the clinical monitoring of LMWHs. It is therefore proposed that each of the LMWHs should be cross referenced by its own standard and the clinical monitoring of these drugs should only be carried out utilizing the specific drug used in a given patient. The PiCT test offers a global test which is capable of monitoring the effects of all components of heparins regardless of their affinity to serpines. Moreover, the effect of TFPI released on clotting processes is also measured. Thus, the PiCT test provides a physiologically relevant anticoagulant index.


Sign in / Sign up

Export Citation Format

Share Document