Ex vivo Mechanical Testing of Various Suture Patterns for Use in Plating as a Repair Method for Tendon Rupture

2019 ◽  
Author(s):  
M.J. Hale ◽  
E.M. Zellner ◽  
J. Naiman ◽  
K. Kraus
2021 ◽  
Author(s):  
Michael J. Hale ◽  
Eric M. Zellner ◽  
Jaron H. Naiman ◽  
Karl H. Kraus

Author(s):  
Logan M. Scheuermann ◽  
Michael G. Conzemius

Abstract Objective The aim of this study was to investigate the effects of an induced incomplete ossification of the humeral condyle (IOHC) lesion on ex vivo canine humeral condylar biomechanics. Study Design Nine paired cadaveric elbows were collected from mature dogs weighing between 20 and 25 kg. Left and right limbs were randomized to IOHC or normal groups. Limbs were prepared for mechanical testing; ligaments were preserved and an IOHC lesion was created. Elbows were potted, positioned into a biomaterials testing system at an angle of 135 degrees and axially loaded to failure at a rate of 30 mm/minute. Results Induced IOHC lesions reduced peak load (p = 0.02) when compared with an intact humerus. There was no difference between stiffness (p = 0.36) of intact humeri or humeri with an induced IOHC lesion. An induced IOHC lesion increased (p = 0.012) the probability of intracondylar fracture under load. Conclusion Cadaveric humeri are weakened by the creation of an intracondylar osteotomy and fractures secondary to induced IOHC are similar to spontaneous humeral condylar fractures. These findings support the hypothesis that naturally occurring IOHC weakens the humeral condyle and may predispose to humeral condylar fracture.


Author(s):  
Remigiusz M. Grzeskowiak ◽  
James Schumacher ◽  
Pierre-Yves Mulon ◽  
Richard C. Steiner ◽  
Lynne Cassone ◽  
...  
Keyword(s):  

2011 ◽  
Vol 25 (8) ◽  
pp. 459-461 ◽  
Author(s):  
Jacob L Cartner ◽  
Zane M Hartsell ◽  
William M Ricci ◽  
Paul Tornetta

2019 ◽  
Vol 141 (11) ◽  
Author(s):  
Amy A. Claeson ◽  
Edward J. Vresilovic ◽  
Brent L. Showalter ◽  
Alexander C. Wright ◽  
James C. Gee ◽  
...  

Nucleotomy is a common surgical procedure and is also performed in ex vivo mechanical testing to model decreased nucleus pulposus (NP) pressurization that occurs with degeneration. Here, we implement novel and noninvasive methods using magnetic resonance imaging (MRI) to study internal 3D annulus fibrosus (AF) deformations after partial nucleotomy and during axial compression by evaluating changes in internal AF deformation at reference loads (50 N) and physiological compressive loads (∼10% strain). One particular advantage of this methodology is that the full 3D disc deformation state, inclusive of both in-plane and out-of-plane deformations, can be quantified through the use of a high-resolution volumetric MR scan sequence and advanced image registration. Intact grade II L3-L4 cadaveric human discs before and after nucleotomy were subjected to identical mechanical testing and imaging protocols. Internal disc deformation fields were calculated by registering MR images captured in each loading state (reference and compressed) and each condition (intact and nucleotomy). Comparisons were drawn between the resulting three deformation states (intact at compressed load, nucleotomy at reference load, nucleotomy at compressed load) with regard to the magnitude of internal strain and direction of internal displacements. Under compressed load, internal AF axial strains averaged −18.5% when intact and −22.5% after nucleotomy. Deformation orientations were significantly altered by nucleotomy and load magnitude. For example, deformations of intact discs oriented in-plane, whereas deformations after nucleotomy oriented axially. For intact discs, in-plane components of displacements under compressive loads oriented radially outward and circumferentially. After nucleotomy, in-plane displacements were oriented radially inward under reference load and were not significantly different from the intact state at compressed loads. Re-establishment of outward displacements after nucleotomy indicates increased axial loading restores the characteristics of internal pressurization. Results may have implications for the recurrence of pain, design of novel therapeutics, or progression of disc degeneration.


2018 ◽  
Vol 46 (12) ◽  
pp. 2981-2989 ◽  
Author(s):  
Zili Wang ◽  
Xuhui Liu ◽  
Michael R. Davies ◽  
Devante Horne ◽  
Hubert Kim ◽  
...  

Background: Rotator cuff (RC) tears are common tendon injuries seen in orthopaedic patients. Successful repair of large and massive RC tears remains a challenge due to our limited understanding of the pathophysiological features of this injury. Clinically relevant small animal models that can be used to study the pathophysiological response to repair are limited by the lack of chronic repair models. Purpose: To develop a highly clinically relevant mouse model of delayed RC repair. Study Design: Controlled laboratory study. Methods: Three-month-old C57BL/6J mice underwent unilateral supraspinatus (SS) and infraspinatus (IS) tendon tear with immediate, 2-week delayed, or 6-week delayed tendon repair. Animals with no repair or sham surgery served as controls. Gait analysis was conducted to measure shoulder function at 2 weeks and 6 weeks after surgery. Animals were sacrificed 6 weeks after the last surgery. Shoulder joint, SS, and IS muscles were harvested and analyzed histologically. Ex vivo mechanical testing of intact and repaired SS and IS tendons was conducted. Reverse-transcriptase polymerase chain reaction was performed on SS and IS muscles to quantify atrophy, fibrosis, and fatty infiltration–related gene expression. Results: Histological and tendon mechanical testing showed that torn tendons could be successfully repaired as late as 6 weeks after transection. However, significant atrophy and fatty infiltration of muscle, with impaired shoulder function, were persistent in the 6-week delayed repair group. Shoulder function correlated with the severity of RC muscle weight loss and fatty infiltration. Conclusion: We successfully developed a clinically relevant mouse model of delayed RC repair. Six-week delayed RC repair resulted in persistent muscle atrophy and fatty infiltration with inferior shoulder function compared with acute repair. Clinical Relevance: Our novel mouse model could serve as a powerful tool to understand the pathophysiological and cellular/molecular mechanisms of RC muscle and tendon degeneration, eventually improving our strategies for treating and repairing RC tears.


2021 ◽  
pp. 089875642110109
Author(s):  
Jane E. Pegg ◽  
Jennifer E. Rawlinson ◽  
Jennifer L Kelley ◽  
Eric Monnet

The purpose of the study was to determine the effect of suture pattern and repair length on the load to failure in an ex vivo canine gingival model. Healthy mandibular gingiva and mucosa were harvested from fresh cadavers euthanized for purposes unrelated to the study. Samples were randomly assigned by length and pattern. Lingual and buccal free gingival margins were apposed using a simple interrupted (SI), cruciate (XT), simple continuous (SC), or unidirectional knotless continuous barbed suture (SF) closure technique with USP 4-0 poliglecaprone 25i, ii applied over 2 lengths (3 cm and 6 cm). A custom template was used to ensure uniform suture bite application. Surgical time was recorded. Using a soft tissue mechanical testing frame, samples were tensioned to failure. Testing was video recorded and reviewed in conjunction with the tension trace data for tension at initial failure (Tfail) and maximum tension sustained (Tmax). Two factor ANOVA by length and pattern was performed followed by individual one way T-tests. Statistically significant findings were XT-SC-SF patterns were quicker to perform than SI. SF was more likely to fail by suture breakage than tissue tearing, and SF withstood less tension at the 3 cm length than SI-XT-SC. No significant difference was detected in Tmax or Tfail between SI and SC or XT. The study demonstrates that SC and XT are comparable to SI in tension resistance and faster to perform suggesting that SC and XT could replace SI for extraction site closure although further in vivo testing is required.


2012 ◽  
Vol 81 (2) ◽  
pp. 211-215
Author(s):  
Lucie Urbanová ◽  
Iva Blažek-Fialová ◽  
Robert Srnec ◽  
Jan Pěnčík ◽  
Přemysl Kršek ◽  
...  

The study deals with the possibility of substituting time- and material-demanding mechanical testing of a bone defect fixation by mathematical modelling. Based on the mechanical model, a mathematical model of bone-implant construct stabilizing experimental segmental femoral bone defect (segmental ostectomy) in a miniature pig ex vivo model using 4.5 mm titanium LCP was created. It was subsequently computer-loaded by forces acting parallel to the long axis of the construct. By the effect of the acting forces the displacement vector sum of individual construct points occurred. The greatest displacement was noted in the end segments of the bone in close proximity to ostectomy and in the area of the empty central plate hole (without screw) at the level of the segmental bone defect. By studying the equivalent von Mises stress σEQV on LCP as part of the tested construct we found that the greatest changes of stress occur in the place of the empty central plate hole. The distribution of this strain was relatively symmetrical along both sides of the hole. The exceeding of the yield stress value and irreversible plastic deformations in this segment of LCP occurred at the acting of the force of 360 N. These findings are in line with the character of damage of the same construct loaded during its mechanic testing. We succeeded in creating a mathematical model of the bone-implant construct which may be further used for computer modelling of real loading of similar constructs chosen for fixation of bone defects in both experimental and clinical practice.


Sign in / Sign up

Export Citation Format

Share Document