Cadaveric Evaluation of Load to Failure in Canine Gingiva Apposed With Varied Suture Patterns Using Poliglecaprone 25

2021 ◽  
pp. 089875642110109
Author(s):  
Jane E. Pegg ◽  
Jennifer E. Rawlinson ◽  
Jennifer L Kelley ◽  
Eric Monnet

The purpose of the study was to determine the effect of suture pattern and repair length on the load to failure in an ex vivo canine gingival model. Healthy mandibular gingiva and mucosa were harvested from fresh cadavers euthanized for purposes unrelated to the study. Samples were randomly assigned by length and pattern. Lingual and buccal free gingival margins were apposed using a simple interrupted (SI), cruciate (XT), simple continuous (SC), or unidirectional knotless continuous barbed suture (SF) closure technique with USP 4-0 poliglecaprone 25i, ii applied over 2 lengths (3 cm and 6 cm). A custom template was used to ensure uniform suture bite application. Surgical time was recorded. Using a soft tissue mechanical testing frame, samples were tensioned to failure. Testing was video recorded and reviewed in conjunction with the tension trace data for tension at initial failure (Tfail) and maximum tension sustained (Tmax). Two factor ANOVA by length and pattern was performed followed by individual one way T-tests. Statistically significant findings were XT-SC-SF patterns were quicker to perform than SI. SF was more likely to fail by suture breakage than tissue tearing, and SF withstood less tension at the 3 cm length than SI-XT-SC. No significant difference was detected in Tmax or Tfail between SI and SC or XT. The study demonstrates that SC and XT are comparable to SI in tension resistance and faster to perform suggesting that SC and XT could replace SI for extraction site closure although further in vivo testing is required.

Author(s):  
Jessica L. Corrie ◽  
Daniel J. Duffy ◽  
Yi-Jen Chang ◽  
George E. Moore

Abstract OBJECTIVE To evaluate the effect of knot location on the biomechanical strength and gapping characteristics of ex vivo canine gastrocnemius tenorrhaphy constructs. SAMPLE 36 cadaveric gastrocnemius tendons from 18 adult dogs. PROCEDURES Tendons were randomly assigned to 3 groups (12 tendons/group) and sharply transected and repaired by means of a core locking-loop suture with the knot at 1 of 3 locations (exposed on the external surface of the tendon, buried just underneath the external surface of the tendon, or buried internally between the apposed tendon ends). All repairs were performed with size-0 polypropylene suture. All constructs underwent a single load-to-failure test. Yield, failure, and peak forces, mode of failure, and forces required for 1- and 3-mm gap formation were compared among the 3 knot-location groups. RESULTS Mean yield, failure, and peak forces and mean forces required for 1- and 3-mm gap formation did not differ significantly among the 3 groups. The mode of failure also did not differ significantly among the 3 groups, and the majority (33/36 [92%]) of constructs failed owing to the suture pulling through the tendinous substance. CONCLUSIONS AND CLINICAL RELEVANCE Final knot location did not significantly affect the biomechanical strength and gapping characteristics of canine gastrocnemius tenorrhaphy constructs. Therefore, all 3 evaluated knot locations may be acceptable for tendon repair in dogs. In vivo studies are necessary to further elucidate the effect of knot location in suture patterns commonly used for tenorrhaphy on tendinous healing and collagenous remodeling at the repair site.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Alan Feiveson ◽  
Kerry George ◽  
Mark Shavers ◽  
Maria Moreno-Villanueva ◽  
Ye Zhang ◽  
...  

AbstractSpace radiation consists of energetic protons and other heavier ions. During the International Space Station program, chromosome aberrations in lymphocytes of astronauts have been analyzed to estimate received biological doses of space radiation. More specifically, pre-flight blood samples were exposed ex vivo to varying doses of gamma rays, while post-flight blood samples were collected shortly and several months after landing. Here, in a study of 43 crew-missions, we investigated whether individual radiosensitivity, as determined by the ex vivo dose–response of the pre-flight chromosome aberration rate (CAR), contributes to the prediction of the post-flight CAR incurred from the radiation exposure during missions. Random-effects Poisson regression was used to estimate subject-specific radiosensitivities from the preflight dose–response data, which were in turn used to predict post-flight CAR and subject-specific relative biological effectiveness (RBEs) between space radiation and gamma radiation. Covariates age, gender were also considered. Results indicate that there is predictive value in background CAR as well as radiosensitivity determined preflight for explaining individual differences in post-flight CAR over and above that which could be explained by BFO dose alone. The in vivo RBE for space radiation was estimated to be approximately 3 relative to the ex vivo dose response to gamma irradiation. In addition, pre-flight radiosensitivity tended to be higher for individuals having a higher background CAR, suggesting that individuals with greater radiosensitivity can be more sensitive to other environmental stressors encountered in daily life. We also noted that both background CAR and radiosensitivity tend to increase with age, although both are highly variable. Finally, we observed no significant difference between the observed CAR shortly after mission and at > 6 months post-mission.


Micromachines ◽  
2020 ◽  
Vol 11 (9) ◽  
pp. 861
Author(s):  
Elizabeth E. Niedert ◽  
Chenghao Bi ◽  
Georges Adam ◽  
Elly Lambert ◽  
Luis Solorio ◽  
...  

A microrobot system comprising an untethered tumbling magnetic microrobot, a two-degree-of-freedom rotating permanent magnet, and an ultrasound imaging system has been developed for in vitro and in vivo biomedical applications. The microrobot tumbles end-over-end in a net forward motion due to applied magnetic torque from the rotating magnet. By turning the rotational axis of the magnet, two-dimensional directional control is possible and the microrobot was steered along various trajectories, including a circular path and P-shaped path. The microrobot is capable of moving over the unstructured terrain within a murine colon in in vitro, in situ, and in vivo conditions, as well as a porcine colon in ex vivo conditions. High-frequency ultrasound imaging allows for real-time determination of the microrobot’s position while it is optically occluded by animal tissue. When coated with a fluorescein payload, the microrobot was shown to release the majority of the payload over a 1-h time period in phosphate-buffered saline. Cytotoxicity tests demonstrated that the microrobot’s constituent materials, SU-8 and polydimethylsiloxane (PDMS), did not show a statistically significant difference in toxicity to murine fibroblasts from the negative control, even when the materials were doped with magnetic neodymium microparticles. The microrobot system’s capabilities make it promising for targeted drug delivery and other in vivo biomedical applications.


2013 ◽  
Vol 26 (05) ◽  
pp. 356-365 ◽  
Author(s):  
K. L. Wendelburg ◽  
S. Tepic ◽  
S. M. Stover ◽  
T. Garcia-Nolen ◽  
P. B. Stearns ◽  
...  

SummaryElbow dysplasia, primarily affecting the medial compartment, is the most common cause of lameness in the thoracic limb. Elbow arthroplasty is an option for end stage or severely affected patients. The purpose of this study was to compare ex vivo axial load to failure of an implanted novel elbow arthroplasty system to control limbs. The partial arthroplasty is a medial compartmental, unconstrained system, intended to allow conversion to total arthroplasty. We hypothesized that there would not be any significant difference between implanted and controlled limbs when loaded to failure. Six pairs of medium mixed breed canine cadaveric thoracic limbs were prepared for comparison of failure loading of control and implanted limbs. Axial compression was performed using a mechanical testing system. Failure loads were normalized to bodyweight. The mean normalized failure load (N/kg) for the implanted limbs and control limbs were 2.47 (range: 1.62-3.38) and 2.68 (range: 2.25-3.25), respectively. An implanted to control ratio of 0.93 ± 0.19 was calculated. The difference between paired control and implanted limbs in normalized failure loading was not significant (p = 0.38). There were not any differences noted in the yield load (p = 0.30), stiffness (p = 0.62), or energy (0.58). Failure modes were recorded. We concluded that the differences between implanted and control limbs in supra-physiologic axial load to failure were not significant.


Author(s):  
Shuo Sun ◽  
Xiaofang Zhou ◽  
Zhian Li ◽  
Ping Zhuang

A combination of an in vitro physiologically based extraction test (PBET) and an in vivo mouse model was used to determine Cd oral bioaccessibility and estimate bioavailability in Cd-contaminated rice. The PBET found lower Cd bioaccessibility in the intestinal stage (40–50%) than in the gastric stage (93–98%) for both rice and mouse chow. No significant difference was found in Cd bioaccessibility between contaminated rice and Cd-amended mouse chow in the gastric or gastrointestinal phase (except for rice 1). The result of the in vivo bioassay revealed that Cd absorption in the kidney or liver of mice fed with contaminated rice were significantly higher than in the mouse chow group containing an equal Cd concentration. Correlation analysis between concentrations of different elements in mouse chow or rice and Cd concentrations in mice kidney or liver showed that Fe, Ca, Cu, and Zn had significant negative correlation (r2 > 0.7, p < 0.01). These results suggest that nutritional elements in the diet could affect Cd absorption and distribution in organs and that different food matrices may result in unequal Cd health risks at an equal Cd concentration due to the specific mineral content of food.


2012 ◽  
Vol 37 (2) ◽  
pp. 101-108 ◽  
Author(s):  
T. H. Low ◽  
T. S. Ahmad ◽  
E. S. Ng

We have compared a simple four-strand flexor tendon repair, the single cross-stitch locked repair using a double-stranded suture (dsSCL) against two other four-strand repairs: the Pennington modified Kessler with double-stranded suture (dsPMK); and the cruciate cross-stitch locked repair with single-stranded suture (Modified Sandow). Thirty fresh frozen cadaveric flexor digitorum profundus tendons were transected and repaired with one of the core repair techniques using identical suture material and reinforced with identical peripheral sutures. Bulking at the repair site and tendon–suture junctions was measured. The tendons were subjected to linear load-to-failure testing. Results showed no significant difference in ultimate tensile strength between the Modified Sandow (36.8 N) and dsSCL (32.6 N) whereas the dsPMK was significantly weaker (26.8 N). There were no significant differences in 2 mm gap force, stiffness or bulk between the three repairs. We concluded that the simpler dsSCL repair is comparable to the modified Sandow repair in tensile strength, stiffness and bulking.


2017 ◽  
Vol 38 (6) ◽  
pp. 3647
Author(s):  
Claudia Lizandra Ricci ◽  
Rogério Giuffrida ◽  
Glaucia Prada Kanashiro ◽  
Hilidia Stephania Rufino Belezzi ◽  
Carolina De Carvalho Bacarin ◽  
...  

The objective of this study was to evaluate the use of the Kowa HA-2 applanation tonometer in measuring intraocular pressure (IOP) in cats. Ten healthy eyes were used in an ex vivo study in which the calibration curve for manometry vs. tonometry was determined by artificially raising the IOP in 5 mmHg increments up to 60 mmHg (10-60 mmHg). Both eyes of 10 anesthetized cats were studiedin vivo to compare manometry vs. tonometry. In the ambulatory study, 78 healthy eyes, 7 eyes with glaucoma and 20 eyes with uveitis were evaluated by tonometry, which was performed with topical anesthesia and 1% fluorescein eye drops for the formation of fluorescein semicircles. The correlation coefficient (r²) between the manometer and the Kowa HA-2 tonometer was 0.993 and the linear regression equation was y = 0.0915x + 0.0878 in the ex-vivo study. In the in vivo study, the IOP values (mean±SD, in mmHg) in manometry were 15.6 ± 1.1(14.0 – 17.5) and in tonometry were 15.5 ± 1.2(13.5 – 17.2), with no significant difference (P > 0.05) between manometry and tonometry. In ambulatory study, using the Kowa HA-2 tonometer, the IOP values (mean±SD, in mmHg) were 15.0 ± 1.5 (11.8 – 18.3) for the healthy eyes, 38.4 ± 8.1(29.6 – 53.7) for glaucomatous eyes and 10.4 ± 2.0(5.3 – 12.2) for eyes with uveitis. There was a strong correlation and accuracy between the IOP values with the manometry and the Kowa HA-2 tonometer. In the ambulatorystudy the IOP values obtained with the tonometer were compatible for animals with healthy eyes and with clinical signs of glaucoma and uveitis. We conclude that the Kowa HA-2 tonometer can be used in the measurement of IOP in cats, since it is a practical and accurate method in this species.


2021 ◽  
Vol 2021 ◽  
pp. 1-9
Author(s):  
Lisa C. Adams ◽  
Julia Brangsch ◽  
Jan O. Kaufmann ◽  
Dilyana B. Mangarova ◽  
Jana Moeckel ◽  
...  

Background. Currently, there is no reliable nonsurgical treatment for abdominal aortic aneurysm (AAA). This study, therefore, investigates if doxycycline reduces AAA growth and the number of rupture-related deaths in a murine ApoE−/− model of AAA and whether gadofosveset trisodium-based MRI differs between animals with and without doxycycline treatment. Methods. Nine ApoE−/− mice were implanted with osmotic minipumps continuously releasing angiotensin II and treated with doxycycline (30 mg/kg/d) in parallel. After four weeks, MRI was performed at 3T with a clinical dose of the albumin-binding probe gadofosveset (0.03 mmol/kg). Results were compared with previously published wild-type control animals and with previously studied ApoE−/− animals without doxycycline treatment. Differences in mortality were also investigated between these groups. Results. In a previous study, we found that approximately 25% of angiotensin II-infused ApoE−/− mice died, whereas in the present study, only one out of 9 angiotensin II-infused and doxycycline-treated ApoE−/− mice (11.1%) died within 4 weeks. Furthermore, doxycycline-treated ApoE−/− mice showed significantly lower contrast-to-noise (CNR) values ( p = 0.017 ) in MRI compared to ApoE−/− mice without doxycycline treatment. In vivo measurements of relative signal enhancement (CNR) correlated significantly with ex vivo measurements of albumin staining (R2 = 0.58). In addition, a strong visual colocalization of albumin-positive areas in the fluorescence albumin staining with gadolinium distribution in LA-ICP-MS was shown. However, no significant difference in aneurysm size was observed after doxycycline treatment. Conclusion. The present experimental in vivo study suggests that doxycycline treatment may reduce rupture-related deaths in AAA by slowing endothelial damage without reversing aneurysm growth.


2021 ◽  
Vol 10 (9) ◽  
Author(s):  
Laura R. Bear ◽  
Matthijs Cluitmans ◽  
Emma Abell ◽  
Julien Rogier ◽  
Louis Labrousse ◽  
...  

Background Dispersion and gradients in repolarization have been associated with life‐threatening arrhythmias, but are difficult to quantify precisely from surface electrocardiography. The objective of this study was to evaluate electrocardiographic imaging (ECGI) to noninvasively detect repolarization‐based abnormalities. Methods and Results Ex vivo data were obtained from Langendorff‐perfused pig hearts (n=8) and a human donor heart. Unipolar electrograms were recorded simultaneously during sinus rhythm from an epicardial sock and the torso‐shaped tank within which the heart was suspended. Regional repolarization heterogeneities were introduced through perfusion of dofetilide and pinacidil into separate perfusion beds. In vivo data included torso and epicardial potentials recorded simultaneously in anesthetized, closed‐chest pigs (n=5), during sinus rhythm, and ventricular pacing. For both data sets, ECGI accurately reconstructed T‐wave electrogram morphologies when compared with those recorded by the sock (ex vivo: correlation coefficient, 0.85 [0.52–0.96], in vivo: correlation coefficient, 0.86 [0.52–0.96]) and repolarization time maps (ex‐vivo: correlation coefficient, 0.73 [0.63–0.83], in vivo: correlation coefficient, 0.76 [0.67–0.82]). ECGI‐reconstructed repolarization time distributions were strongly correlated to those measured by the sock (both data sets, R 2 ≥0.92). Although the position of the gradient was slightly shifted by 8.3 (0–13.9) mm, the mean, max, and SD between ECGI and recorded gradient values were highly correlated ( R 2 =0.87, 0.75, and 0.86 respectively). There was no significant difference in ECGI accuracy between ex vivo and in vivo data. Conclusions ECGI reliably and accurately maps potentially critical repolarization abnormalities. This noninvasive approach allows imaging and quantifying individual parameters of abnormal repolarization‐based substrates in patients with arrhythmogenesis, to improve diagnosis and risk stratification.


2017 ◽  
Vol 35 (7_suppl) ◽  
pp. 10-10
Author(s):  
Régine Audran ◽  
Haithem Chtioui ◽  
Anne-Christine Thierry ◽  
Carole Mayor ◽  
Laure Vallotton ◽  
...  

10 Background: Trastuzumab is a humanized monoclonal antibody targeting breast cancer cells overexpressing the HER2-oncoprotein. During a Phase-I single centre, single dose, randomized, double-blind, cross-over study assessing the bioequivalence of a proposed trastuzumab biosimilar (MYL-1401O) versus the initially marketed drug (Herceptin), we investigated in addition a large panel of pharmacodynamics parameters comparing the immunomodulatory activity of both drugs. Methods: 22 healthy males were included, 19 subjects receiving randomly a single intravenous infusion of MYL-1401O and 22 of Herceptin, separated by 16 to 22 week wash-out. Blood samples drawn pre- and post- infusion were assessed for in vivo serum cytokines induction (IL-1β, IL-2, IL-6, IL-10, IL-12, TNF-α, GM-CSF and IFN-γ) whereas the impact of treatment on mononuclear cell subsets and their level of activation was tested ex vivo. Volunteers’ PBMC (peripheral blood monocnuclear cells) were stimulated in vitro with recall antigens and mitogen for cytokine production. At baseline, we performed in addition a cytokine release assay on PBMC upon stimulation with trastuzumab as a preclinical safety test. Results: Trastuzumab infusion induced a transient and weak peak of serum IL-6 at 6h, and a modulation of mononuclear cell subset profile and level of activation. Notably CD16+ cells frequency decreased at 3h and peaked at 48h. Except for CD8+ T cells, there were no significant differences between Herceptin and its proposed biosimilar ex vivo. PBMC stimulated in vitro with trastuzumab secreted IL-6, TNF-a, IL-1β, GM-CSF, IFN-γ, and IL-10, but no IL-2. There was no significant difference between the two mAbs. Conclusions: Based on these in vivo, ex vivo and in vitro experiments, there is a strong assumption that MYL-1401O is biosimilar to the reference drug Herceptin for its immunomodulation properties as already proven for its bioequivalence. Clinical trial information: 2011-001406-94.