scholarly journals Application of Polydioxanone Sutures in the Nuss Procedure

Author(s):  
Yimin Xie ◽  
Jinbo Ning

Abstract Background/Purpose The Nuss procedure is the most common surgical repair for pectus excavatum (PE). Surgical steel wires are used in some modifications of the Nuss procedure to attach one or both ends of a support bar to the ribs. During follow-up, wire breakage was found in some cases. Patients with wire breakage may undergo prolonged bar removal surgery and may be exposed to excessive radiation.In this study, we had a series of patients who received polydioxanone suture (PDS) fixations instead of steel wires. This retrospective study was conducted to explore the differences between these two fixation materials in the incidence of related complications and efficacies. Furthermore, we attempted to observe whether the two materials lead to similar surgical efficacy in the Nuss procedure, whether they have divergent effects on the bar removal surgery, and whether PDS can reduce the risks due to steel wire breakage as expected. Methods We retrospectively studied PDS and surgical steel wires as fixation materials for the Nuss procedure in children with congenital PE and reviewed the outcomes and complications. A total of 75 children who had undergone Nuss procedure repairs and bar removals from January 2013 to December 2019 were recruited to participate in this study. They were divided into three groups: the PDS group, the unbroken wire (UBW) group, and the broken wire (BW) group, according to the fixation materials and whether the wires had broken or not. Moreover, we selected the duration of operation (DO), intraoperative blood loss (BL), bar displacement (BD), postoperative pain score (PPS), and incision infection as the risk indicators and the postrepair Haller index (HI) as the effectiveness indicator. These indicators were statistically compared to determine whether there were differences among the three groups. Results One BD occurred in the PDS and BW groups while none took place in the UBW group. No incision infection was found in any of the groups. The PDS group had the shortest DO, while the DO in the UBW group was shorter than that in the BW group (p < 0.05). BL in the PDS group was less than that in the other two groups (p < 0.05). Additionally, no difference was observed in BL between the BW and UBW groups (p > 0.05). The PPS of the PDS group was less than that of the BW group (p < 0.05), whereas no differences were found between the other two groups. No statistical difference emerged in HI among the groups (p > 0.05). Conclusion PDS fixation results in a similar repair outcome and shows certain advantages in the DO, BL, and PPS; also, PDSs are safe and effective in the Nuss procedure. Level of evidence Level III.

2019 ◽  
Vol 7 (2) ◽  
pp. 232596711982731 ◽  
Author(s):  
Graham D. Pallante ◽  
Shawn W. O’Driscoll

Background: The hook test is a sensitive and specific tool that has been previously described for diagnosing distal biceps tendon ruptures in an efficient, cost-effective manner. However, its application in postoperative evaluations after surgical repair of distal biceps tendon ruptures is not documented. Hypothesis/Purpose: We hypothesized that the hook test result returns to normal at some point postoperatively after distal biceps repair. This information could be used in decision making during follow-up examinations with both normal and abnormal findings. Study Design: Cohort study (diagnosis); Level of evidence, 3. Methods: We retrospectively reviewed records of distal biceps repair. Between July 1, 2003, and July 1, 2016, a total of 56 patients underwent distal biceps repair and also had clear documentation of the results of the hook test during the postoperative period. Hook test results consisted of “intact,” “abnormal,” or “absent.” The timing of the return to a normal hook test result was recorded. Results: Overall, 51 of 57 (89%) repairs were documented to have the hook test result return to “intact.” The test result returned to intact by a mean of 10 weeks after surgery (range, 2 weeks to 15 months). The biceps tendon was intact according to the hook test at the 4-month follow-up in 45 of the 51 patients (88%) in whom it ultimately returned. The hook test result was abnormal in 5 repairs in 5 patients with only a short-term follow-up, ranging from 2 to 7 weeks postoperatively. One patient with an abnormal hook test result at 2 weeks postoperatively underwent revision and was confirmed to have a partial tear of the biceps insertion. His hook test result returned to intact 3 months after revision repair. Conclusion: The hook test result returns to normal in patients who undergo distal biceps repair in the primary and revision settings with adequate follow-up. The vast majority of patients have a normal hook test result by 4 months postoperatively. An abnormal hook test result at 4 months postoperatively may indicate a failed repair and should prompt further investigation.


2000 ◽  
Vol 10 (5) ◽  
pp. 519-526 ◽  
Author(s):  
M. Carminati ◽  
S. Giusti ◽  
G. Hausdorf ◽  
S. Qureshi ◽  
M. Tynan ◽  
...  

AbstractIn this review, we describe the experience from 13 European centres using the CardioSEAL and Starflex double umbrella devices to close interatrial communications within the oval fossa (so-called ‘stcundum’ defects). Between October 1996 and April 1999, the procedure was attempted in 334 patients with a mean age of 12 years and a mean weight of 44kg. The mean measured stretched diameter of the defect was 15 mm. In the overall group, the defect was solitary in 245 patients (73%), multiple in 21 (6%), associated with an aneurysm of the flap valve in 15 (5%), was represented by patency of the oval foramen in 44 (13%), and was a fenestration in a Fontan repair in 9 (3%). In all patients, the devices were inserted under general anesthesia, using fluoroscopic and transesophageal echocardiographic control. Implantation was achieved in 325 (97,3%). The device embolized within either a few minutes or a few hours in 13 patients (4%). Of these, uncomplicated surgical repair was undertaken in 10, while the device was retrieved in 3 using catheters and a second device was successfully implanted. Residual shunting was detected immediately after the procedure in 41% of the patients, with the incidence decreasing to 31% at discharge, 24% at 1 month, 21% at 6 months, and 20.5% at one year. During the period of follow-up, elective surgical repair became necessary in two patients, due to malposition of the device in one, and late embolization in the other. Fractures of arms were seen in 6.1%, most commonly with the largest devices. All those with fractured arms of the device were asymptomatic, and no clinical complications related to the fractures were observed. There were no arrythmias, endocarditis, valvar distortion, thromboembolic events, or other complications. After one year of follow-up, clinical success, defined as complete closure of the defect or presence of only a trivial leak, had been obtained in 92.5% of the patients. We conclude, therefore, that these devices produce excellent results when used to close defects of small to moderate size. Results are less than optimal, or else complications ensure, when attempts are made to close very large defects.


2015 ◽  
Vol 100 (3) ◽  
pp. 540-546
Author(s):  
Qingmin Zeng ◽  
Guoping Cai ◽  
Dechang Liu ◽  
Kun Wang ◽  
Xinchao Zhang

Emergency treatment of amputation is one of the most frequently used therapeutic methods for patients with severe upper limb crush injury with a mangled extremity severity score (MESS) of more than 7. With the development of advanced surgical repair techniques and reconstructive technology, cases that once required amputation can now be salvaged with appropriate management, and some limb functions may also be reserved. A patient with a severe upper limb crush injury with a MESS score of 10 was treated in our hospital. The limb was salvaged after 9 surgeries over 10 months. The follow-up visits over the next 18 months post-injury showed that the shoulder joint functions were rated as “excellent” (90) according to the Neer score, the Harris hip evaluation (HHS) for elbow joint functions was “good” (80), and the patient was very satisfied with the overall therapeutic outcome. We conclude from the successful outcome of this extreme injury that salvage attempts should be the first management choice for upper limbs with complex injuries to save as much function as possible. Amputation should only be adopted when the injury is life-threatening or no more function can be saved. The level of evidence was V.


2021 ◽  
Vol 49 (9) ◽  
pp. 030006052110412
Author(s):  
Duanchao Shu ◽  
Jianpeng Li ◽  
Yixin Zhao ◽  
Yan Yang

Objective To compare the sternal fixation effect of a polyetheretherketone (PEEK) cable product and stainless steel wire after median sternotomy. Methods A multicentre retrospective clinical trial was conducted in patients that underwent median sternotomy for a range of surgical reasons. The sternum was fixed using PEEK sternal cables in the experimental group and stainless steel wires in the control group. The general patient state, product manoeuvrability, bone and wound healing state and blood test results were evaluated at seven visits during the preoperative, surgical and follow-up periods. Results A total of 108 patients (54 in each group) were included in the analysis at the final 180-day follow-up. The sternum was successfully closed using PEEK cables or steel wires in all patients and all healed well. No pathological changes were found on the X-ray imaging. Computed tomography imaging confirmed ideal fracture healing. No significant difference was found between the experimental group and the control group in outcomes. Conclusion PEEK cables are easy to implant and show desirable effectiveness in sternal fixation without any observed side-effects.


Author(s):  
Michelle D.M.E. Meeks ◽  
Pieter W.J. Lozekoot ◽  
Stefan E. Verstraeten ◽  
Mischa Nelis ◽  
Jos G. Maessen

Objective Mediastinitis is a severe complication of cardiac surgery. Sternal instability is concomitantly present in most cases. Broken steel wires may cause sternal instability. In this study, the role of broken steel wires in sternal closure was evaluated in patients who developed poststernotomy mediastinitis. Methods Preoperative, perioperative, and postoperative data of patients who underwent thoracic surgery between 1996 and 2006 were retrieved from the SUMMIT registry database. Patients needing reoperation for mediastinitis were identified. Patients’ charts and chest radiographs from initial surgery to reoperation for mediastinitis were reviewed. Results Forty-five patients developed postoperative mediastinitis needing reoperation (0.6%). Because of loss to follow-up, 31 patients were evaluated. Eight patients (25.8%) presented fractured steel wires. Most of the broken steel wires (87.5%) manifested at the cranial site of figure-of-eight configurations. In the patients without broken steel wires, mediastinitis manifested after 14 days compared with 38 days in the patients with broken wires. Time until mediastinitis was not significantly different (P = 0.229). The mean time until steel wire disruption was 14 days (range, 4–48 days). Conclusions Broken steel wires were observed before mediastinitis became manifest. Fracturing occurred mainly at the cranial site of figure-of-eight configurations. The results of the present study emphasize that closure technique plays a prominent role in the development of mediastinitis. Because mediastinitis is associated with an increased risk for early morbidity, attention should be paid to patients presenting with broken steel wires. New techniques for median sternotomy closure are needed that are less prone to mechanical fatigue than are steel wires.


2020 ◽  
Vol 48 (8) ◽  
pp. 1974-1982 ◽  
Author(s):  
Atif Ayuob ◽  
Babar Kayani ◽  
Fares S. Haddad

Background: Injuries to the hamstring complex most commonly involve the proximal musculotendinous junction of the long head of the biceps femoris (MTJ-BFlh). Nonoperative management of these injuries is associated with prolonged rehabilitation and high risk of recurrence. To our knowledge, the surgical management of acute MTJ-BFlh injuries has not been previously reported. Hypothesis: Surgical repair of acute MTJ-BFlh injuries enables return to sporting activity with low risk of recurrence. Study Design: Case series; Level of evidence, 4. Methods: A total of 64 patients (42 male and 22 female) undergoing surgical repair of acute MTJ-BFlh injuries were included. Predefined outcomes were recorded at regular intervals after surgery. Mean follow-up time after surgery was 29.2 months (range, 24.0-37.1 months). Results: All study patients returned to their preinjury levels of sporting activity. Mean ± SD time from surgical intervention to return to sporting activity was 13.4 ± 5.1 weeks. Three patients had reinjury at the operative site: 1 (1.6%) with MTJ-BFlh injury and 2 (3.2%) with myofascial tears. At 3 months after surgery, patients had improved mean passive straight-leg raise (72.0° ± 11.4° vs 24.1° ± 6.8°; P < .001); increased mean isometric hamstring muscle strength at 0° (84.5 % ± 10.4% vs 25.9% ± 8.9%; P < .001), 15° (89.5% ± 7.3% vs 41.2% ± 9.7%; P < .001), and 45° (93.9% ± 5.1% vs 63.4% ± 7.6%; P < .001); higher mean Lower Extremity Functional Scale scores (71.5 ± 5.0 vs 29.8 ± 6.3; P < .001); and improved mean Marx activity rating scores (9.8 ± 2.2 vs 3.8 ± 1.9; P < .001), as compared with preoperative scores. High patient satisfaction and functional outcome scores were maintained at 1 and 2 years after surgery. Conclusion: Surgical repair of acute MTJ-BFlh injuries enables return to preinjury level of sporting function with low risk of recurrence at short-term follow-up.


VASA ◽  
2014 ◽  
Vol 43 (1) ◽  
pp. 6-26 ◽  
Author(s):  
Fabian Rengier ◽  
Philipp Geisbüsch ◽  
Paul Schoenhagen ◽  
Matthias Müller-Eschner ◽  
Rolf Vosshenrich ◽  
...  

Transcatheter aortic valve replacement (TAVR) as well as thoracic and abdominal endovascular aortic repair (TEVAR and EVAR) rely on accurate pre- and postprocedural imaging. This review article discusses the application of imaging, including preprocedural assessment and measurements as well as postprocedural imaging of complications. Furthermore, the exciting perspective of computational fluid dynamics (CFD) based on cross-sectional imaging is presented. TAVR is a minimally invasive alternative for treatment of aortic valve stenosis in patients with high age and multiple comorbidities who cannot undergo traditional open surgical repair. Given the lack of direct visualization during the procedure, pre- and peri-procedural imaging forms an essential part of the intervention. Computed tomography angiography (CTA) is the imaging modality of choice for preprocedural planning. Routine postprocedural follow-up is performed by echocardiography to confirm treatment success and detect complications. EVAR and TEVAR are minimally invasive alternatives to open surgical repair of aortic pathologies. CTA constitutes the preferred imaging modality for both preoperative planning and postoperative follow-up including detection of endoleaks. Magnetic resonance imaging is an excellent alternative to CT for postoperative follow-up, and is especially beneficial for younger patients given the lack of radiation. Ultrasound is applied in screening and postoperative follow-up of abdominal aortic aneurysms, but cross-sectional imaging is required once abnormalities are detected. Contrast-enhanced ultrasound may be as sensitive as CTA in detecting endoleaks.


2018 ◽  
Vol 8 (2) ◽  
pp. 35-48
Author(s):  
Jiří Rybička ◽  
Petra Čačková

One of the tools to determine the recommended order of the courses to be taught is to set the prerequisites, that is, the conditions that have to be fulfilled before commencing the study of the course. The recommended sequence of courses is to follow logical links between their logical units, as the basic aim is to provide students with a coherent system according to the Comenius' principle of continuity. Declared continuity may, on the other hand, create organizational complications when passing through the study, as failure to complete one course may result in a whole sequence of forced deviations from the recommended curriculum and ultimately in the extension of the study period. This empirical study deals with the quantitative evaluation of the influence of the level of initial knowledge given by the previous study on the overall results in a certain follow-up course. In this evaluation, data were obtained that may slightly change the approach to determining prerequisites for higher education courses.


2018 ◽  
Vol 2 ◽  
pp. 247154921880777
Author(s):  
Zachary J Bloom ◽  
Cesar D Lopez, BA ◽  
Stephen P Maier ◽  
Brian B Shiu ◽  
Djuro Petkovic ◽  
...  

Introduction Lesser tuberosity osteotomy (LTO) during anatomic total shoulder arthroplasty has a 13% nonunion rate. Treatment for LTO nonunion is controversial and poorly described in the literature. The purpose of this study was to compare the surgical and nonsurgical treatment outcomes of LTO nonunion. Methods A retrospective case series of 9 consecutive patients with LTO nonunion after primary anatomic shoulder arthroplasty at 1 institution from 2010 to 2016 were studied. Outcomes measured were radiographic evaluation of LTO on axillary X-ray, clinical range of motion (ROM), subscapularis strength, and pain at the time of LTO nonunion diagnosis and after either conservative care or surgical repair of the LTO nonunion. Results LTO nonunion was treated surgically in 4 and conservatively in 5 patients with average follow-up of 30 and 22 months, respectively. There were no significant differences in age, sex, or smoking status between groups. Treatment decision was a shared model of surgeon and patient. Displaced LTO nonunion was treated surgically in 2 and conservatively in 3 patients. There were no differences in LTO union rate of 50% in the surgical versus 60% in the conservative group. Abdominal compression test was abnormal in 50% of surgical versus 40% of conservative groups. At follow-up, ROM was lower in the surgical group with 128° forward elevation (FE) and 33° external rotation (ER) compared to 148° FE and 62° ER. Only 1 patient with LTO nonunion required conversion to reverse replacement. Conclusion LTO nonunion after shoulder arthroplasty is rare. Surgical repair of LTO nonunion does not significantly improve clinical or radiographic outcomes compared to conservative care.


Sign in / Sign up

Export Citation Format

Share Document