Total Wrist Arthroplasty Alignment and Its Potential Association with Clinical Outcomes

Author(s):  
Bardiya Akhbari ◽  
Kalpit N. Shah ◽  
Amy M. Morton ◽  
Janine Molino ◽  
Douglas C. Moore ◽  
...  

Abstract Purpose There is a lack of quantitative research that describes the alignment and, more importantly, the effects of malalignment on total wrist arthroplasty (TWA). The main goal of this pilot study was to assess the alignment of TWA components in radiographic images and compare them with measures computed by three-dimensional analysis. Using these measures, we then determined if malalignment is associated with range of motion (ROM) or clinical outcomes (PRWHE, PROMIS, QuickDash, and grip strength). Methods Six osteoarthritic patients with a single type of TWA were recruited. Radiographic images, computed tomography images, and clinical outcomes of the wrists were recorded. Using posteroanterior and lateral radiographs, alignment measurements were defined for the radial and carpal components. Radiographic measurements were validated with models reconstructed from computed tomography images using Bland–Altman analysis. Biplanar videoradiography (<1mm and <1 degree accuracy) was used to capture and compute ROM of the TWA components. Linear regression assessed the associations between alignment and outcomes. Results Radiographic measures had a 95% limit-of-agreement (mean difference ±  1.96 × SD) of 3 degrees and 3mm with three-dimensional values, except for the measures of the carpal component in the lateral view. In our small cohort, wrist flexion–extension and radial–ulnar deviation were correlated with volar–dorsal tilt and volar–dorsal offset of the radial component and demonstrated a ROM increase of 3.7 and 1.6 degrees per degree increase in volar tilt, and 10.8 and 4.2 degrees per every millimeter increase in volar offset. The carpal component's higher volar tilt was also associated with improvements in patient-reported pain. Conclusions We determined metrics describing the alignment of TWA, and found the volar tilt and volar offset of the radial component could potentially influence the replaced wrist's ROM. Clinical Relevance TWA component alignment can be measured reliably in radiographs, and may be associated with clinical outcomes. Future studies must evaluate its role in a larger cohort.

2019 ◽  
Vol 141 (4) ◽  
Author(s):  
Bardiya Akhbari ◽  
Amy M. Morton ◽  
Douglas C. Moore ◽  
Arnold-Peter C. Weiss ◽  
Scott W. Wolfe ◽  
...  

Total wrist arthroplasty (TWA) for improving the functionality of severe wrist joint pathology has not had the same success, in parameters such as motion restoration and implant survival, as hip, knee, and shoulder arthroplasty. These other arthroplasties have been studied extensively, including the use of biplane videoradiography (BVR) that has allowed investigators to study the in vivo motion of the total joint replacement during dynamic activities. The wrist has not been a previous focus, and utilization of BVR for wrist arthroplasty presents unique challenges due to the design characteristics of TWAs. Accordingly, the aims of this study were (1) to develop a methodology for generating TWA component models for use in BVR and (2) to evaluate the accuracy of model-image registration in a single cadaveric model. A model of the carpal component was constructed from a computed tomography (CT) scan, and a model of the radial component was generated from a surface scanner. BVR was acquired for three anatomical tasks from a cadaver specimen. Optical motion capture (OMC) was used as the gold standard. BVR's bias in flexion/extension, radial/ulnar deviation, and pronosupination was less than 0.3 deg, 0.5 deg, and 0.6 deg. Translation bias was less than 0.2 mm with a standard deviation of less than 0.4 mm. This BVR technique achieved a kinematic accuracy comparable to the previous studies on other total joint replacements. BVR's application to the study of TWA function in patients could advance the understanding of TWA, and thus, the implant's success.


2019 ◽  
Vol 44 (9) ◽  
pp. 946-950 ◽  
Author(s):  
Stefan M. Froschauer ◽  
Maximilian Zaussinger ◽  
Dietmar Hager ◽  
Manfred Behawy ◽  
Oskar Kwasny ◽  
...  

We evaluated the outcomes of the Re-motion total wrist arthroplasty in 39 non-rheumatoid patients. The mean follow-up was 7 years (range 3–12). Postoperative wrist flexion-extension and radial-ulnar deviation as well as the scores of the Disability of Arm Shoulder and Hand questionnaire and the visual analogue scale pain scores improved significantly. Complications occurred in 13 wrists, five of which required further surgery. The most frequent complication was impingement between the scaphoid and the radial implant (n = 5), which can be avoided by complete or almost complete scaphoid resection. Periprosthetic radiolucency developed around the radial component in three cases and three radial screws loosened. Despite the incidence of high implant survival in 38 of 39 wrists over 7 years (97%), the complication rate is not satisfying. Knowledge of the risk of complications and patient selection are essential when making the decision to choose wrist arthroplasty over arthrodesis. Level of evidence: IV


2020 ◽  
Vol 25 (5) ◽  
pp. 805-811
Author(s):  
Tatsuki Mizouchi ◽  
Keiichi Katsumi ◽  
Tomohiro Izumi ◽  
Akiyoshi Yamazaki ◽  
Hirokazu Shoji ◽  
...  

2020 ◽  
Vol 4 (2) ◽  
pp. 208-211 ◽  
Author(s):  
Yutaro Sugiura ◽  
Takuji Iwamoto ◽  
Taku Suzuki ◽  
Hiroo Kimura ◽  
Noboru Matsumura ◽  
...  

2020 ◽  
Vol 1 (1) ◽  
pp. 62-70
Author(s):  
Amir H Sadeghi ◽  
Wouter Bakhuis ◽  
Frank Van Schaagen ◽  
Frans B S Oei ◽  
Jos A Bekkers ◽  
...  

Abstract Aims Increased complexity in cardiac surgery over the last decades necessitates more precise preoperative planning to minimize operating time, to limit the risk of complications during surgery and to aim for the best possible patient outcome. Novel, more realistic, and more immersive techniques, such as three-dimensional (3D) virtual reality (VR) could potentially contribute to the preoperative planning phase. This study shows our initial experience on the implementation of immersive VR technology as a complementary research-based imaging tool for preoperative planning in cardiothoracic surgery. In addition, essentials to set up and implement a VR platform are described. Methods Six patients who underwent cardiac surgery at the Erasmus Medical Center, Rotterdam, The Netherlands, between March 2020 and August 2020, were included, based on request by the surgeon and availability of computed tomography images. After 3D VR rendering and 3D segmentation of specific structures, the reconstruction was analysed via a head mount display. All participating surgeons (n = 5) filled out a questionnaire to evaluate the use of VR as preoperative planning tool for surgery. Conclusion Our study demonstrates that immersive 3D VR visualization of anatomy might be beneficial as a supplementary preoperative planning tool for cardiothoracic surgery, and further research on this topic may be considered to implement this innovative tool in daily clinical practice. Lay summary Over the past decades, surgery on the heart and vessels is becoming more and more complex, necessitating more precise and accurate preoperative planning. Nowadays, operative planning is feasible on flat, two-dimensional computer screens, however, requiring a lot of spatial and three-dimensional (3D) thinking of the surgeon. Since immersive 3D virtual reality (VR) is an upcoming imaging technique with promising results in other fields of surgery, we aimed in this study to explore the additional value of this technique in heart surgery. Our surgeons planned six different heart operations by visualizing computed tomography scans with a dedicated VR headset, enabling them to visualize the patient’s anatomy in an immersive and 3D environment. The outcomes of this preliminary study are positive, with a much more reality-like simulation for the surgeon. In such, VR could potentially be beneficial as a preoperative planning tool for complex heart surgery.


Author(s):  
Theodore J. Heindel ◽  
Terrence C. Jensen ◽  
Joseph N. Gray

There are several methods available to visualize fluid flows when one has optical access. However, when optical access is limited to near the boundaries or not available at all, alternative visualization methods are required. This paper will describe flow visualization using an X-ray system that is capable of digital X-ray radiography, digital X-ray stereography, and digital X-ray computed tomography (CT). The unique X-ray flow visualization facility will be briefly described, and then flow visualization of various systems will be shown. Radiographs provide a two-dimensional density map of a three dimensional process or object. Radiographic images of various multiphase flows will be presented. When two X-ray sources and detectors simultaneously acquire images of the same process or object from different orientations, stereographic imaging can be completed; this type of imaging will be demonstrated by trickling water through packed columns and by absorbing water in a porous medium. Finally, local time-averaged phase distributions can be determined from X-ray computed tomography (CT) imaging, and this will be shown by comparing CT images from two different gas-liquid sparged columns.


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Jae-Young Kim ◽  
Michael D. Han ◽  
Kug Jin Jeon ◽  
Jong-Ki Huh ◽  
Kwang-Ho Park

Abstract Background The purpose of this study was to investigate the differences in configuration and dimensions of the anterior loop of the inferior alveolar nerve (ALIAN) in patients with and without mandibular asymmetry. Method Preoperative computed tomography images of patients who had undergone orthognathic surgery from January 2016 to December 2018 at a single institution were analyzed. Subjects were classified into two groups as “Asymmetry group” and “Symmetry group”. The distance from the most anterior and most inferior points of the ALIAN (IANant and IANinf) to the vertical and horizontal reference planes were measured (dAnt and dInf). The distance from IANant and IANinf to the mental foramen were also calculated (dAnt_MF and dInf_MF). The length of the mandibular body and symphysis area were measured. All measurements were analyzed using 3D analysis software. Results There were 57 total eligible subjects. In the Asymmetry group, dAnt and dAnt_MF on the non-deviated side were significantly longer than the deviated side (p < 0.001). dInf_MF on the non-deviated side was also significantly longer than the deviated side (p = 0.001). Mandibular body length was significantly longer on the non-deviated side (p < 0.001). There was no significant difference in length in the symphysis area (p = 0.623). In the Symmetry group, there was no difference between the left and right sides for all variables. Conclusion In asymmetric patients, there is a difference tendency in the ALIAN between the deviated and non-deviated sides. In patients with mandibular asymmetry, this should be considered during surgery in the anterior mandible.


2021 ◽  
Vol 10 (9) ◽  
pp. 1865
Author(s):  
Stefan M. Froschauer ◽  
Matthias Holzbauer ◽  
Dietmar Hager ◽  
Oskar Kwasny ◽  
Dominik Duscher

High complication rates in total wrist arthroplasty (TWA) still lead to controversy in the medical literature, and novel methods for complication reduction are warranted. In the present retrospective cohort study, we compare the outcomes of the proximal row carpectomy (PRC) method including total scaphoidectomy (n = 22) to the manufacturer’s conventional carpal resection (CCR) technique, which retains the distal pole of the scaphoid (n = 25), for ReMotion prosthesis implantation in non-rheumatoid patients. Mean follow-up was 65.8 ± 19.8 and 80.0 ± 28.7 months, respectively. Pre- and postoperative clinical assessment included wrist flexion-extension and radial-ulnar deviation; Disability of Arm, Shoulder, and Hand scores; and pain via visual analogue scale. At final follow-up, grip strength and satisfaction were evaluated. All complications, re-operations, and revision surgeries were noted. Clinical complications were significantly lower in the PRC group (p = 0.010). Radial impaction was detected as the most frequent complication in the CCR group (n = 10), while no PRC patients suffered from this complication (p = 0.0008). Clinical assessment, grip strength measurements, and the log rank test evaluating the re-operation as well as revision function showed no significant difference. All functional parameters significantly improved compared to preoperative values in both cohorts. In conclusion, we strongly recommend PRC for ReMotion prosthesis implantation.


Sign in / Sign up

Export Citation Format

Share Document