Experimental Investigation of the Residual Physical and Mechanical Properties of Foamed Concrete Exposed to High Temperatures

Author(s):  
Xudong Chen ◽  
Dandan Shi ◽  
Jinhua Zhang ◽  
Xiyuan Cheng
2019 ◽  
Vol 2019 ◽  
pp. 1-10 ◽  
Author(s):  
Qifang Xie ◽  
Lipeng Zhang ◽  
Shenghua Yin ◽  
Baozhuang Zhang ◽  
Yaopeng Wu

Fires are always known for seriously deteriorating concrete in structures, especially for those with certain carbonation due to long-time service. In this paper, 75 prism specimens were prepared and divided into four groups (three carbonated groups and one uncarbonated group). Specimens were tested under different temperatures (20, 300, 400, 500, 600, and 700°C), exposure times (3, 4, and 6 hours), and cooling methods (water and natural cooling). Surface characteristics, weight loss rate, and residual mechanical properties (strength, initial elastic modulus, peak, and ultimate compressive strains) of carbonated concrete specimens after elevated temperatures were investigated and compared with that of the uncarbonated ones. Results show that the weight loss rates of the carbonated concrete specimens are slightly lower than that of the uncarbonated ones and that the cracks are increased with raising of temperatures. Surface colors of carbonated concrete are significantly changed, but they are not sensitive to cooling methods. Surface cracks can be evidently observed on carbonated specimens when temperature reaches 400°C. Residual compressive strength and initial elastic modulus of carbonated concrete after natural cooling are generally larger than those cooled by water. The peak and ultimate compressive strains of both carbonated and uncarbonated concrete specimens increase after heating, but the values of the latter are greater than that of the former. Finally, the constitutive equation to predict the compressive behaviors of carbonated concrete after high temperatures was established and validated by tests.


2019 ◽  
Vol 30 (2) ◽  
pp. 81-97
Author(s):  
Pradnya Eknath Kosbe ◽  
◽  
Pradeep Anandrao Patil ◽  
Muthukumar Manickam ◽  
Gurunathan Ramamurthy ◽  
...  

2015 ◽  
Vol 747 ◽  
pp. 213-216 ◽  
Author(s):  
Md Azree Othuman Mydin ◽  
Mohd Yazid Mohd Yunos ◽  
Mohd Nasrun Mohd Nawi ◽  
Adi Irfan Che Ani

Even though lightweight foamed concrete has low mechanical properties compared to normal weight concrete, there is a potential of using this material as partition or load-bearing wall in low-rise residential construction. Before it can be considered for use as a load-bearing element in the building industry, it is necessary to acquire reliable information of its mechanical properties at ambient and high temperatures for quantification of its fire resistance performance. This paper will present the results of experiments that have been carried out to examine and characterize the residual compressive strength of foamed concrete after high temperatures. Foamed concrete with 700 kg/m3 and 1000 kg/m3 density were cast and tested. The compression tests were carried out at ambient temperature, 100, 200, 300, 400, 500 and 600°C.


Sign in / Sign up

Export Citation Format

Share Document