Failure Criteria and Constitutive Model of Polypropylene Fiber–Reinforced Expansive Self-Consolidating Concrete under Biaxial Loading

Author(s):  
Qi Cao ◽  
Xianrui Lv ◽  
Zhimin Wu ◽  
Changjun Zhou ◽  
Xingchao Wang
Author(s):  
Haider A. Abdulhameed ◽  
Hani Nassif ◽  
Kamal H. Khayat

The use of fiber-reinforced self-consolidating concrete (FR-SCC) in repairing damaged concrete beams has been evaluated. An experimental program was conducted to design and test key fresh and hardened properties of SCC and FR-SCC mixtures. The designed FR-SCC mixtures included two types of supplementary cementitious materials (silica fume (SF) and slag (SL)) and two types of fibers (steel fiber (STF) and polypropylene fiber (PPF)) were used. To ensure good workability to repair congested areas, the optimized volume fractions of the STF were 0.25% and 0.50% compared with 0.10%, 0.15%, and 0.20% for the PPF. In addition, the flexural behavior of 10 beam specimens was investigated. The main reinforcement for the control beams consisted of #5 reinforcing bars, while the main reinforcement for the repaired beams was either #4 or #3 reinforcing bars that were introduced to simulate 35% and 65% reduction of the bar areas, respectively, due to corrosion. The results demonstrate that the optimized FR-SCC mixtures are effective repair materials and can develop adequate bond strength to existing concrete. The flexural test results showed that the repair mixtures were able to increase the cracking load for the repaired beams compared with the control beams. Such an increase is expected to contribute to extending the life of the damaged member or structure at the service load level. This paper also presents a comparison of the predicted values for the first-crack load strength using the ACI 544 code equation with the experimental data. Results showed that the code equation provides safe prediction.


2021 ◽  
Vol 28 (6) ◽  
pp. 1829-1842
Author(s):  
Ying Wang ◽  
Jin Liu ◽  
Yong Shao ◽  
Xiao-fan Ma ◽  
Chang-qing Qi ◽  
...  

Polymers ◽  
2021 ◽  
Vol 13 (15) ◽  
pp. 2476
Author(s):  
Haiwen Li ◽  
Sathwik S. Kasyap ◽  
Kostas Senetakis

The use of polypropylene fibers as a geosynthetic in infrastructures is a promising ground treatment method with applications in the enhancement of the bearing capacity of foundations, slope rehabilitation, strengthening of backfills, as well as the improvement of the seismic behavior of geo-systems. Despite the large number of studies published in the literature investigating the properties of fiber-reinforced soils, less attention has been given in the evaluation of the dynamic properties of these composites, especially in examining damping characteristics and the influence of fiber inclusion and content. In the present study, the effect of polypropylene fiber inclusion on the small-strain damping ratio of sands with different gradations and various particle shapes was investigated through resonant column (macroscopic) experiments. The macroscopic test results suggested that the damping ratio of the mixtures tended to increase with increasing fiber content. Accordingly, a new expression was proposed which considers the influence of fiber content in the estimation of the small-strain damping of polypropylene fiber-sand mixtures and it can be complementary of damping modeling from small-to-medium strains based on previously developed expressions in the regime of medium strains. Additional insights were attempted to be obtained on the energy dissipation and contribution of fibers of these composite materials by performing grain-scale tests which further supported the macroscopic experimental test results. It was also attempted to interpret, based on the grain-scale tests results, the influence of fiber inclusion in a wide spectrum of properties for fiber-reinforced sands providing some general inferences on the contribution of polypropylene fibers on the constitutive behavior of granular materials.


Sign in / Sign up

Export Citation Format

Share Document